background image

Page 3

SKU 99969

For technical questions, please call 1-800-444-3353.

the Scale while you are tired or un-

der the influence of drugs, alcohol 

or medication.

  A moment of inatten-

tion while operating the Scale may 

result in serious personal injury.

Always wear eye protection when 

b. 

performing maintenance.  

Safety 

equipment such as ANSI-approved 

safety impact goggles will reduce 

personal injuries.

Do not overreach.  Keep proper 

c. 

footing and balance at all times.

  

This enables better control of the 

Scale in unexpected situations.

Scale use and care

3. 

Do not force the Scale.  use the 

a. 

correct Scale for your application.

  

The correct Scale will do the job bet

-

ter and safer at the rate for which it 

was designed.

Do not use the Scale if the Power 

b. 

Switch does not turn it on and 

off.  

Any equipment that cannot be 

controlled with the Power Switch is 

dangerous and must be repaired.

Remove the Battery (5) before 

c. 

making any adjustments, changing 

accessories, or storing the Scale.  

Such preventive safety measures 

reduce the risk of starting the equip-

ment accidentally.

Store idle equipment out of the 

d. 

reach of children and do not allow 

persons unfamiliar with the Scale 

or these instructions to operate 

the equipment.  

Battery powered 

equipment is dangerous in the hands 

of untrained users.

Maintain the Scale.  Check for 

e. 

misalignment or binding of mov-

ing parts, breakage of parts and 

any other condition that may affect 

the Scale’s operation.  If damaged, 

have the Scale repaired before 

use.

  Many accidents are caused by 

poorly maintained equipment.

use the Scale in accordance with 

f. 

these instructions, taking into ac-

count the working conditions and 

the work to be performed.  

Use of 

the Scale for operations different from 

those intended could result in a haz-

ardous situation.

Do not exceed the Scale’s maxi-

g. 

mum weight capacity of 154 

pounds.
This Scale is not legal for trade or 

h. 

postage.
Do not sit or stand on the Scale.

i. 

Battery use and care

4. 

Use this Scale only with specifi

-

a. 

cally designated Batteries. 

Use of 

any other Battery may create a risk of 

injury and fire.

under abusive conditions, liquid 

b. 

may be ejected from the Battery 

(5).  Avoid contact. If contact ac-

cidentally occurs, flush with water. 

If liquid contacts eyes, additionally 

seek medical help. 

Liquid ejected 

from the Battery may cause irritation 

or burns.

Do not dispose of Battery in fire to 

c. 

avoid explosion.
Service

5. 

Have your Scale serviced by a 

a. 

qualified repair person using only 

identical replacement parts.
Maintain labels and nameplates 

b. 

on the Scale.  

These carry important 

safety information.  If unreadable or 

missing, contact Harbor Freight Tools 

for a replacement.

Содержание 99969

Страница 1: ... by Harbor Freight Tools 3491 Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury Save this manual Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express w...

Страница 2: ...s a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address practices not related to personal injury General Safety Warnings WARNING Read all safety warn ings and instructions Failure to follow the warnings and instruc tions may result in electric ...

Страница 3: ...powered equipment is dangerous in the hands of untrained users Maintain the Scale Check for e misalignment or binding of mov ing parts breakage of parts and any other condition that may affect the Scale s operation If damaged have the Scale repaired before use Many accidents are caused by poorly maintained equipment Use the Scale in accordance with f these instructions taking into ac count the wor...

Страница 4: ...Tare Indicator Overload Indicator Lamp Control Panel Indicators On Off Z T Unit Lamp Additional Features Unit Auto Turn Off After 3 5 Min of Inactivity Lamp Auto Turn Off After 4 0 Min of Unit Inactivity Unpacking When unpacking check to make sure that the item is intact and undamaged If any parts are missing or broken please call Harbor Freight Tools at the number shown on the cover of this manua...

Страница 5: ...rong air currents direct sun shine and high temperature Designate a work area that is well lit 3 The area must not allow access by children or pets to prevent injury and distraction The four Leveling Shoes 11 are 4 used for leveling the unit To level the Scale remove the Scale and its hand held Display unit from the Carrying Case 13 Then use the Leveling Shoes and a carpenter s level not included ...

Страница 6: ... on the Platform 7 first Then press the Z T Key When the Weight Indicator Window displays 000 00 place the bulk goods into the container to obtain the net weight of the goods See Figure C Zero When unloaded if the Weight In dicator Window does not display 000 00 press the Z T Key See Figure C Unit Press the UNIT Key to shift the Scale between pounds and kilo grams See Figure C Background Lamp Pres...

Страница 7: ...ed or broken parts Battery leakage and any other condition that may affect its safe operation BATTERY REPLACEMENT 2 Refer to Figure A page 5 for instructions IMPORTANT The old Battery 5 must be recycled or disposed of ac cording to local solid waste authority instructions After Use 3 Clean all external surfaces of the Scale with soft clean cloth Do not use solvents Do not immerse the Scale in liqu...

Страница 8: ...roduct or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the com plaint must accompany the merchandise If our inspection verifies the defect we will ei ther repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement We will return re paired p...