CEN-TECH 98674 Скачать руководство пользователя страница 15

DIGITAL MULTIMETER 

 

 

OPERATING INSTRUCTION 

 

3

The meter will enter the manual range mode after the 

“REL”  button  is  pressed.    REL  mode  is  not  available 

for Hz/Duty range because it is an automatic range. 

4) Press  the  “REL”  button  again  to  cancel  the  relative 

measurement function. 

5

Pressing  the  “REL”  button  at  the  HOLD  mode  will 

cancel the  HOLD function.    The  actual measurement 

value taken will be stored in the memory as reference 

value.    The  readings  displayed  for  measurements 

taken  afterwards  will  be  the  difference  between  the 

input value and the reference value. 

6

Press the “RANGE”, “SELECT” buttons or turning the 

rotary  selector  to  cancel  the  relative  measurement 

function and resume normal measurement.    The REL 

symbol on the display will disappear.   

7

OL triggering: Under the REL mode, OL (over limit) will 

flash  on  the  display  if  the  input  value  exceeds  the 

allowed value for that range.    Press the “REL” button 

again  to  cancel  the  relative  measurement  function.   

The REL mode cannot be entered when OL is flashing.     

 

4.7 BACK LIGHT 

1

 Press the ”HOLD/B.L” button for two or more seconds 

to  switch  on  the  back  light  if  the  light  in  the 

environment is too dim for taking reading,. 

2

Press the “HOLD/B.L” button for two or more seconds   

- 26 - 

DIGITAL MULTIMETER 

 

 

OPERATING INSTRUCTION 

 

again to switch off the back light. 

3

The  back  light  will  go  off  automatically  after  10 

seconds. 

NOTE: 

1)  LED,  which  requires  a  larger  working  current,  is  the 

main  source  of  back  light.    Although  the  meter  is 

equipped with a timer set at 10 seconds (i.e. the back 

light  will  be  off  automatically  after  10  seconds), 

frequent use of the back light will shorten the life of the 

batteries.    Therefore, do not use the back light unless 

necessary. 

2) When  the  battery  voltage  is 

3.6V,  the  symbol  “

battery  low

will  appear  on  the  LCD.    When  the 

back light is on, even if the batter is 

3.6V, the “

” 

may appear because of its large working current which 

will  cause  the  voltage  to  drop.    (The  accuracy  of  the 

measurement 

cannot 

be 

assured 

when 

the 

“  symbol  appears.)    In  this  case,  you  need  not 

replace the batteries yet.    Normally, the batteries can 

last until the “

” appears when the back light is not 

being used. 

 

4.8 AUTO POWER OFF 

1

If  there  is  no  any  operation  within  any  thirty  minute 

period  after  the  power  is  on,  the  meter  will  enter  the 

auto power off mode. 

- 27 - 

Содержание 98674

Страница 1: ...H BUTTONS AND INPUT JACKS 8 2 3 LIQUID CRYSTAL DISPLAY LCD 10 3 SPECIFICATIONS 12 3 1 GENERAL SPECIFICATIONS 12 3 2 TECHNICAL SPECIFICATIONS 13 4 OPERATION INSTRUCTION 23 4 1 MISCONNECTION ALARM 23 4 2 HOLDING READINGS 24 4 3 SWITCHING FUNCTIONS 24 4 4 SWITCHING RANGES 24 4 5 SWITCHING BETWEEN FREQUENCY DUTY 25 4 6 SWITCHING TO RELATIVE MEASUREMENT 25 4 7 BACK LIGHT 26 4 8 AUTO POWER OFF 27 4 9 PR...

Страница 2: ...proper use of this device can result in electric shock or destruction of the meter Take all normal safety precautions and follow the safeguards suggested in this manual To exploit full functionality of the meter and ensure safe operation please read carefully and follow the directions in this manual This meter complies with the general technical requirements for the GB T 19978 92 multimeter as wel...

Страница 3: ...and earth ground exceeds 1000V 1 2 6 Select the highest range if the value scale to be measured in the manual range is unknown 2 DIGITAL MULTIMETER SAFETY INFORMATION NTS 1 2 7 Do not connect the meter to any voltage source while the rotary selector is in the current resistance capacitance diode continuity range 1 2 8 Disconnect the test leads from the circuit under test before turning the rotary ...

Страница 4: ...rformed by a technician who fully understands the meter and the danger involved 1 4 2 Disconnect the test leads from all sources of electric current before opening the battery cover of the mete 1 4 3 To avoid any electric shock caused by error readings replace the batteries immediately when the sign appears on the display 1 4 4 To avoid fire hazards the replacement fuse must meet the specified vol...

Страница 5: ... home and for checking the acoustics of studios auditoriums and hi fi installations The luminance function is applicable to measuring field luminance with full cosine correction for angular incidence of light The humidity and temperature functions are suitable for 6 DIGITAL MULTIMETER SAFETY INFORMATION NTS measuring ambient humidity and temperature as well as temperature of objects The digital mu...

Страница 6: ...tching between auto and manual ranges Hz DUTY Button for switching between Hz and duty measurement REL Button for switching to relative measurement Button for switching between and Rotary Selector for selecting functions and ranges OFF Position for turning off the power 10A Input Jack for measuring current 0 10A mA µA TEMP Input Jack for measuring current 0 400mA and temperature V Ω Hz Input Jack ...

Страница 7: ...ON NTS AC Alternating Current DC Direct Current AC or DC alternating current or direct current Diode Continuity buzzer H Reading being held REL Relative measurement AUTO Auto range Battery low Celsius units Temperature Fahrenheir units Temperature RH Relative Humidity units F Farad Capacitance Ω Ohms Resistance V Volts Voltage A Amperes Current Hz Hertz Frequency Duty Cycle dB Decibel Lux Illumina...

Страница 8: ...er off time 30 min 3 1 13 Specification of resettable fuse F1 500mA 250V 3 1 14 Fuse protection F2 10A 250V quick acting 3 1 15 Operating power 1 5V 3 AAA batteries 3 1 16 Battery low indication on LCD 3 1 17 Temperature factor 0 1 Accuracy 12 DIGITAL MULTIMETER SPECIFICATION NTS 3 1 18 Operating temperature 0 to 40 32 F to 104 F 3 1 19 Storage temperature 10 to 50 10 F to 122 F 3 1 20 Dimension 1...

Страница 9: ...r before the test leads contact the circuit This is normal because the meter is highly sensitive When the test leads contact the circuit the true reading will be shown 14 DIGITAL MULTIMETER SPECIFICATION NTS 3 2 3 DC Current Range Resolution Accuracy 400µA 0 1µA 4000µA 1µA 40mA 10µA 1 2 of reading 3 digits 400mA 100µA 4A 1mA 10A 10mA 2 0 of reading 10 digits Overload protection µA mA ranges resett...

Страница 10: ...400µA ranges 40mV 4000µA ranges 400mV 40mA ranges 40mV 400mA ranges 400mV 4A range 40mV 10A range 100mV Frequency range 40 to 400Hz Response average calibrated in rms of sine wave 16 DIGITAL MULTIMETER SPECIFICATION NTS 3 2 5 Resistance Range Resolution Accuracy 400Ω 0 1Ω 4kΩ 1Ω 40kΩ 10Ω 400k 100Ω 4M 1kΩ 1 2 of reading 2 digits 40M 10kΩ 2 0 of reading 5 digits Open circuit voltage 0 25V Overload p...

Страница 11: ...nput current range 1 4 range rms AC higher input voltage at higher frequency 18 DIGITAL MULTIMETER SPECIFICATION NTS Max input current mA jack µA ranges 4mA mA jack mA ranges 400mA 10A jack 10A Overload Protection µA mA ranges resettable fuses F1 500mA 250V 10A range F2 10A 250V fuse quick acting NOTE When measuring frequency the range by Hz range is larger than that by the Hz of voltage range or ...

Страница 12: ...display Range Resolution Accuracy 20 95 0 1 5 0 RH Operating temperature 0 to 40 Sampling Period 20s 20 DIGITAL MULTIMETER SPECIFICATION NTS 3 2 10 Temperature 3 2 10 1 Temperature on sensor thermoresistor NTC and temperature display Range Resolution Accuracy 0 1 0 to 40 2 0 1 32 to 104 4 Sampling Period 20s 3 2 10 2 Temperature on sensor thermocouple and main display Range Resolution Accuracy 20 ...

Страница 13: ...larms against misconnection of test leads 4 1 1 At V Ω Hz Duty ranges 1 The red lights at the IN and COM jacks will be off after the test leads are plugged in 2 The buzzer will sound upon misconnection of the test leads in the mA or 10A jacks to warn the user At the same time the lights at the IN and COM jacks will flash to remind the user to plug in the test leads there 4 1 2 At µA mA TEMP ranges...

Страница 14: ...vel at each press and return 24 DIGITAL MULTIMETER OPERATING INSTRUCTION to the lowest level when the highest level is reached 3 Press the RANGE button for two or more seconds to return to the auto range 4 5 SWITCHING BETWEEN FREQUENCY DUTY 1 Press the Hz DUTY button at the frequency range to switch between frequency and duty measurement 2 When the meter is at the voltage and current ranges press ...

Страница 15: ...utton for two or more seconds to switch on the back light if the light in the environment is too dim for taking reading 2 Press the HOLD B L button for two or more seconds 26 DIGITAL MULTIMETER OPERATING INSTRUCTION again to switch off the back light 3 The back light will go off automatically after 10 seconds NOTE 1 LED which requires a larger working current is the main source of back light Altho...

Страница 16: ...connection Take away the charged test lead first when disconnecting 28 DIGITAL MULTIMETER OPERATING INSTRUCTION 4 10 MEASURING DC VOLTAGE WARNING Beware of electrocution Pay special attention to avoid electric shock when measuring high voltage Do not input any voltage over 1000V DC which may destroy the internal circuit although a higher voltage can be shown 4 10 1 Plug the black test lead into th...

Страница 17: ...the test leads to the voltage source or load terminals for measurement 4 11 5 Take the reading on the main indicator of the LCD 30 DIGITAL MULTIMETER OPERATING INSTRUCTION NOTE 1 At small voltage range unsteady readings may appear before the test leads contact the circuit This is normal because the meter is highly sensitive When the test leads contact the circuit the true reading will be shown 2 A...

Страница 18: ...utton to switch to DC measurement Then press the RANGE button to choose the auto range or manual range mode 32 DIGITAL MULTIMETER OPERATING INSTRUCTION 4 14 4 Connect the test leads to the circuit for measurement 4 14 5 Take the reading on the main indicator of the LCD The polarity symbol denotes the polarity of the end connected by the red test lead NOTE 1 At the manual range mode when only OL or...

Страница 19: ...OPERATING INSTRUCTION 4 16 MEASURING RESISTANCE WARNING Beware of Electrocution When measuring in circuit resistance make sure that the power of the circuit under test has been turned off and that all capacitors have been fully discharged 4 16 1 Plug the black test lead into the COM jack and the red test lead into the Ω jack 4 16 2 Set the rotary selector to the Ω range position 4 16 3 Press the S...

Страница 20: ...est lead into the jack 4 18 2 Set the rotary selector to the Ω range position 36 DIGITAL MULTIMETER OPERATING INSTRUCTION 4 18 3 Press the SELECT button to switch to test 4 18 4 Connect the red test lead to the anode and the black test lead to the cathode of the diode for testing 4 18 5 Take the reading on the main indicator of the LCD NOTE 1 The meter will show the approximate forward voltage dro...

Страница 21: ...GITAL MULTIMETER OPERATING INSTRUCTION 4 21 MEASURING TEMPERATURE WITH THERMO RESISTOR 4 21 1 This function is used for measuring the ambient temperature around the meter 4 21 2 Turn the rotary selector away from the OFF position 4 21 3 The current ambient temperature will be shown on the temperature indicator of the LCD 4 21 4 Press the button to switch between and measurement NOTE 1 The temperat...

Страница 22: ... environment Therefore the meter should be exposed to the environment for a longer time for accurate reading 40 DIGITAL MULTIMETER OPERATING INSTRUCTION 4 23 MEASURING SOUND LEVEL dB WARNING To avoid damage to the meter do not connect the input plug to any electric signal 4 23 1 Turn the rotary selector to the dB range position 4 23 2 Point the sensor located in the front part of the meter at the ...

Страница 23: ...ressmaking work 750 2000 Office conference room reception room 200 750 42 DIGITAL MULTIMETER OPERATING INSTRUCTION clerical work 700 1 500 typing 1000 2 000 Factory packing passage 150 300 assembly line 300 750 inspection work 750 1 500 electronic parts assembly line 1 500 3 000 Hotel public places washroom 100 200 reception front desk 200 1 000 Shop staircase corridor 150 200 display window packi...

Страница 24: ...1 REPLACING THE BATTERIES WARNING To avoid electric shock make sure that the test leads have been clearly move away from the circuit under measurement before opening the battery cover of the meter 5 1 1 If the sign appears it means that the batteries should be replaced 5 1 2 Loosen the fixing screw of the battery cover and remove it 5 1 3 Replace the exhausted batteries with new ones 5 1 4 Put the...

Страница 25: ...ore opening the battery cover of the meter For protection against fire hazard replace fuses with specified ratings only F 10A 250V quick acting A A A A A A 46 DIGITAL MULTIMETER MAINTENANCE 5 3 REPLACING TEST LEADS WARNING The replacement must be test leads in good working condition with the same or equivalent rating 1000V 10A A test lead must be replaced if the insulation layer has been damaged e...

Страница 26: ...DIGITAL MULTIMETER ACCESSORIES 6 ACCESSORIES 1 Test leads electric rating 1000V 10A 1 pair set 2 Thermocouple K type TP01 1 set 3 Operation Manual 1 copy 48 ...

Страница 27: ...HYS005958 ...

Отзывы: