specificatiOns

Material

ABS housing with LCD screen

Lead

29” lead with 5 7/8” Tip Probe

Maximum Input

600 VAC/600 VDC 

Battery

3 V, CR2032 (included)

Fuse

F250mA250V (Fast-acting 250 mA, 250 V)

 (Fast-acting 250 mA, 250 V)

Meter Functions

AC/DC voltage, AC/DC current, resistance measurement, 
diode/continuity testing

save this manual

You will need the manual for the safety warnings and precautions, assembly instruc-

tions, operating and maintenance procedures, parts list and diagram.  Keep your invoice with 
this manual.  Write the invoice number on the inside of the front cover.  Keep the manual and 
invoice in a safe and dry place for future reference.

safety Warnings anD precautiOns

Warning:

 When using tool, basic safety precautions should always be followed to reduce 

the risk of personal injury and damage to equipment.

read all instructions before using this product!

  

In this manual: 

WARNING indicates a potentially hazardous situation which, if not avoided, could result 
in death or serious personal injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in 
a minor/moderate personal injury or damage to this tool or the unit being tested by it.

Keep your work area clean and well lit.  

Cluttered benches and dark areas invite 

accidents.

Keep children away while operating the Digital multimeter.  

Keep children out of 

the work area.  Not a toy.  Keep away from children.

stay alert.  

Do not operate the Digital Multimeter while tired or under the influence of 

drugs, alcohol, or medication. 

use the correct tool for your application.  

Do not use it for applications other than 

intended.

maintain the Digital multimeter with care.  

Do not use a damaged Digital Multimeter.  

Tag a damaged Digital Multimeter “Do not use” until repaired.

multimeter service must be performed only by qualified repair personnel. 

Service 

or maintenance performed by unqualified personnel could result in a risk of injury.

1.

2.

3.

4.

5.

6.

REV  07k

Содержание 95342

Страница 1: ...llo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury Save this manual Copyright 2007 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical q...

Страница 2: ...ing this product In this manual WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious personal injury CAUTION indicates a potentially hazardous situation which if not avoided may result in a minor moderate personal injury or damage to this tool or the unit being tested by it Keep your work area clean and well lit Cluttered benches and dark areas ...

Страница 3: ... before use Do not test voltage on circuits higher than 600 volts AC or 600 volts DC Do not test current on circuits higher than 200 mA 0 2 amps Do not expose to rain or wet conditions Water entering will increase the risk of electric shock Disconnect the multimeter from the power source before making any adjustments changing accessories or storing the tool Always cap the probe and test lead befor...

Страница 4: ...sense and caution are factors which cannot be built into this product but must be supplied by the operator Unpacking When unpacking check to make sure that the Digital Multimeter is intact and undam aged If any parts are missing or broken please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible Functions Pen Light Hold Mode On Off Function Input Probe Te...

Страница 5: ...d test lead together will change the reading to zero This indicates that the circuit is closed and can conduct current Touch the exposed conductors with the tips of the Test Lead and Probe Read measurement in Ohms If the reading is zero and the tone sounds then there is continuity between the two conductors Diode Test Use the same steps as Measuring Resistance Connect the Probe to the positive pol...

Страница 6: ...ter from rough use It is susceptible to damage from being dropped struck improperly mounted or other abuse The precision movement is similar to a watch works and should be treated accordingly Protect the Multimeter from exposure to water or corrosive materials It should be kept clean and dry Occasional cleaning with a clean rag will extend its life and good appearance Store in a dry location to in...

Страница 7: ...ntal or consequential damages so the above limitation of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or implied including the warranties of merchantability and fitness To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must ...

Отзывы: