3
For Controls
All
CEMLINE
Electric Water Heaters and Boilers use 120 volts for control
operation. Whether 208, 240, 415, or 480 volts are utilized to heat water, the
application line voltage is connected to an isolation transformer that provides
constant 120 volt control power.
Construction
All
CEMLINE
Electric Water Heaters and Boilers are constructed from superior materials
and incorporate only the highest quality components. Each meets or exceeds all applicable
American Society of Mechanical Engineers (A.S.M.E.) Code regulations.
Tanks and Linings
Electric Water Heaters
CEMLINE
Electric Water Heaters are equipped with
STONESTEEL
®
tanks.
Each tank is designed and constructed in strict accordance with the latest
A.S.M.E. Code regulations, stamped in accordance with the applicable section of
the A.S.M.E. Code, and accompanied by the applicable Certificates. Each tank is
manufactured using pressure vessel quality plate and welded by certified welders.
All tanks are registered with the National Board of Boiler and Pressure Vessel
Inspectors.
STONESTEEL
®
tanks are lined with hydraulic cement, using the exclusive
CEMLINE
patented process. This time proven process prevents rust and
corrosion, common to metal tanks, and helps guarantee exceptionally long life.
Electric Boilers
CEMLINE
Electric Boilers are equipped with Carbon (Black) tanks. Each tank is
designed and constructed in strict accordance with the latest A.S.M.E. Code
regulations, stamped in accordance with the applicable section of the A.S.M.E.
Code, and accompanied by the applicable Certificates. Each tank is manufactured
using pressure vessel quality plate and welded by certified welders. All tanks are
registered with the National Board of Boiler and Pressure Vessel Inspectors.
Each
CEMLINE
Electric Water Heater is equipped with an A.S.M.E. approved pressure /
temperature relief valve, providing a means to vent excess pressure and remove
accumulated sediment.
Each boiler is equipped with an A.S.M.E. approved pressure relief valve, providing a
means to vent excess pressure; and a drain for removal of accumulated sediment. Each
unit is also equipped with a drain to remove accumulated sediment.
Содержание EHB
Страница 41: ...38 ...
Страница 62: ...59 9 If no leaks are found follow the startup procedures page 17 to put the unit back on line ...
Страница 63: ...60 Appendix A Typical Wiring Diagrams Figure A 1 Typical Wiring Diagram For Electric Water Heaters ...
Страница 64: ...61 Appendix A cont d ...
Страница 65: ...62 Appendix A cont d ...
Страница 68: ...65 ...