22
Message
Error description
Solution
Accelerator motor reset error.
Replace the faulty component, contact
Cembre.
Accelerator motor minimum
positioning error.
Replace the faulty component, contact
Cembre.
Accelerator motor maximum
positioning error.
Replace the faulty component, contact
Cembre.
Generator power supply frequency
out of range.
Increase the engine idling speed or
replace the generator, contact Cembre.
Motor or pcb driver faulty.
Replace the motor or electronics board,
contact Cembre.
Parameter storage failure in eeprom.
Retry, if it does not work the memory is
damaged, contact Cembre.
Failure to store work data in eeprom.
Electronics board faulty and needs replac-
ing, contact Cembre.
Pressure sensor disconnected or faulty
at start up.
Check the connection.
If the error persists replace the sensor,
contact Cembre.
Pressure off set error at start up.
Replace the pressure sensor, contact
Cembre.
Accelerator cable error disconnected or
disconnected.
Check the two ends of the cable, contact
Cembre.
Error can be reset by pressing buttons
(B) simultaneously for 5 seconds; if
the error persists contact Cembre.
Error messages remain on the display
until they are reset.
001
002
003
004
005
006
007
009
6.3) ERRORS:
these appear during operation and notify the operator of procedural or operational errors.
B
010
011