5
(1)
Directive 2006/42/EC, annexe 1, point 1.7.4.2 letter u
L
pA
= weighted continuous acoustic pressure level equivalent.
L
pCPeak
= maximum value of the weighted acoustic displacement pressure at the work place.
L
WA
= acoustic power level emitted by the machine.
(2)
Directive 2006/42/EC, annexe 1, point 2.2.1.1
Weighted root mean square in frequency of the acceleration the upper limbs are exposed to for each biodynamic
reference axis. Tests carried out in compliance with the indications contained in EN ISO 5349-1/2 Standard, and under
operating conditions much more severe than those normally found.
1. GENERAL CHARACTERISTICS
ENGLISH
B500
B500E
B500T
B500A
Application range
suitable for installing electrical compression connectors on
conductors up to 300 mm
2
(600 MCM)
Rated crimping force
kN (US sh. ton)
63 (7.1)
Minimum crimping force
kN (US sh. ton)
60 (6.75)
Minimum operating pressure
bar (psi)
661 (9587)
Dimensions (ref. to Fig. 7)
mm (inches)
300 x 343 x 83 (11.8 x 13.5 x 3.3)
Weight with battery
kg (lbs)
4,2 (9.2)
Motor V
DC
18
Operating temperature
°C (°F)
-15 to +50 (+5 to +122)
Recommended oil
ENI ARNICA ISO 32 or equivalents
Operating speed
twin speed operation and automatic switching from a rapid
advancing speed of the ram to a slower, more powerful
crimping speed
Safety
maximum pressure valve
Rechargeable battery
V / Ah / Wh
18 / 5.2 / 93.6
Type
CB1852 (Li-Ion)
Weight
kg (lbs)
0,66 (1.45)
Battery charger
ASC30-36
Input
type
EU
27044000
UK
27045000
AUS/NZ
27047000
USA/CAN
27046000
V / Hz
220 - 240 / 50 - 60
115 / 60
W
85
Acoustic noise
(1)
L
pA
dB (A)
73
L
pCPeak
dB (C)
94.5
L
WA
dB (A)
79
Vibration
(2)
m/s
2
0.575 max.