![CEM DT-9929 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/cem/dt-9929/dt-9929_user-manual_2580999012.webp)
11
AC CURRENT (FREQUENCY, DUTY CYCLE) MEASUREMENTS
CAUTION:
Do not make 20A current measurements for longer
than 30 seconds. Exceeding 30 seconds may cause damage to
the meter and/or the test leads.
1. Insert the black test lead banana plug into the
negative
COM
jack.
2. For current measurements up to 4000µA AC,
set the function switch to the yellow
µA
position
and insert the red test lead banana plug into the
µA/mA
jack.
3. For current measurements up to 400mA AC, set
the function switch to the yellow
mA
position
and insert the red test lead banana plug into the
µA/mA
jack.
4. For current measurements up to 20A AC, set
the function switch to the yellow
10A/HZ/%
position and insert the red test lead banana plug
into the
10A
jack.
5. Press the
MODE
button to
indicate “
AC
” on the display.
6. Remove power from the circuit under test, then open up the
circuit at the point where you wish to measure current.
7. Touch the black test probe tip to the neutral side of the circuit.
Touch the red test probe tip to the
“hot” side of the circuit.
8. Apply power to the circuit.
9. Read the current in the display. In the 10AAC range, right
auxiliary display frequency.
10. Press and hold the
MODE
button to indicate “
Hz
”.
11. Read the frequency in the display.
12. Momentarily press the
MODE
button a
gain to indicate “
%
”.
13. Read the % duty cycle in the display.
14. Press and hold the
MODE
button to return to current
measurement.
15. Press EXIT for 2 seconds into the function of AC+DC. Test DC
and AC TURE Rms.
Содержание DT-9929