CEM Systems Ethernet Communication Module ECM Скачать руководство пользователя страница 2

Physical

Size 

140 x 110 x 35mm (5.5 x 4.3 x 1.4”)

Weight 

0.2Kg

Housing 

Plastic enclosure or PCB only

Housing colour 

Beige

Power
   - Voltage 

12Vdc

   - Current 

250mA (excluding reader)

   Consumption

Environmental
Temperature 

-10°C to 55°C  

LED Indicators 

+12 Volts Power

 

RS485 Rx and Tx

 
Tibbo LED Indicators 

Ethernet 100BaseT 

 

Ethernet Link

 

Status Red

 

Status Green

Functionality

Inputs 

10/100MB Ethernet via RJ45 connector

 
Outputs 

RS232 via DB9 connector

 

RS485 via 2 part screw terminal

Reader Power Output 

12V, limited to 750mA (MAX) to power a  

 

single CEM reader. Excludes lock power

Configuration 

Configurable via Device Server Toolkit,  

 

telnet or serial connection

communication interFace

To Host 

10/100 Base-T TCP/IP using CAT5/6  

 

Unshielded twisted pair Cable 

   Connection 

RJ45 

To RS485 Card Reader  RS485 multidrop cable runs using using  
 

Belden 8723 with maximum length of  

 

1.2km without repeater 

   Connection 

2 part screw terminal

Product codes

ECM/200/000   

ECM (Complete with PSU and Enclosure)

ECM/200/B04 

ECM Board Only Module 

 

(For use in CEM legacy Systems)

CEM Systems Ltd Unit 4 Ravenhill Business Park Ravenhill Road Belfast BT6 8AW Northern Ireland

Tel:  +44 (0)28 9045 6767  Fax: +44 (0)28 9045 4535  email: [email protected]

www.cemsys.com

PRODUCT HIGHLIGHTS

CEM/B/052 

Product specifications and availability is subject to change without notice.  Certain product names mentioned herein may be trade names 
and/or registered trademarks of their companies.

technical sPeciFications

serial reader/device compatibility on an iP system

The ECM improves communications by enabling traditional serial 
card readers/devices to be quickly and easily connected to an 
IP-based Ethernet network. A board only option is available to 
connect into a NCN device in an existing CEM legacy system.

rs485 network compatibility

A single ECM can be connected to a chain of up to 16 RS485 
readers and multi-dropped up to a distance of 1.2KM.

system compatibility

The ECM can be used with the AC2000 SE (Standard Edition) or 
the AC2000 Lite access control systems.

Packaging options

The ECM is supplied as a standalone boxed unit. A board only 
option is available to connect into a NCN device in an existing 
CEM Legacy System. 

Windows configuration

The ECM makes use of a Tibbo Ethernet module for connection 
to the Ethernet network. Tibbo supply a simple Device Server 
Toolkit (DST) application for setup and network configuration. 
Sample configuration files for standalone and legacy (ENCN) 
modes of operation are supplied.

Отзывы: