TSR-UL-0061-1.3
CHAPTER 3 :
Wiring the Terminal
20
3.8 Configuration information
The emerald terminal facilitates the use of a third party exit Wiegand head with three LEDs.
Power connections
The 12V power connections on J18 connect to the same common circuitry and are used to
provide power to the emerald terminal, as well as to output power to door furniture.
Typical Wiegand read head wiring
For specific read head wiring consult the third party manufacturer’s documentation.
Important
For proper regulatory compliance, the drain wire should be disconnected at the power supplied end of the cable.
Input configuration
The table below illustrates the configuration and operation of the terminal inputs when
configured with a third party Wiegand read head.
Note
Inputs are not for use as part of a burglar alarm system.
Inputs not in use
The door position input 0 must be shorted out between the IP0 and GND pins with wire when
not in use, to prevent alarms being generated on the system.
Ethernet cable ferrite
The ferrite must be attached to the Ethernet cable close to the exit point from the emerald
terminal. The cable should be looped through the ferrite once.
I/O board connection
Typical HID colour
0V
Black
Sounder
Not Supported
LED Green
Orange
LED Amber
Not fitted
LED Red
Brown
D1
White
D0
Green
Head 12V
Red
Table 12: Typical Wiegand head wiring
Input number
Input function
Default input trigger state change
0
Door position
short => open
1
Lock position
short => open
2
Request to exit
switch open => momentary short => open
3
Spare / Interlock
short => open
Table 13: emerald and third party read head input configuration
Содержание emerald TS100
Страница 1: ...TSR UL 0061 1 3 emerald Quick Start Installation Guide...
Страница 4: ...TSR UL 0061 1 3 This page is intentionally blank...
Страница 13: ...emerald Quick Installation Guide 7 1 3 Hardware Installation Process Figure 5 Hardware installation flow chart...
Страница 14: ...TSR UL 0061 1 3 CHAPTER 1 Introduction 8...
Страница 34: ...TSR UL 0061 1 3 26 This page is intentionally blank...
Страница 38: ...TSR UL 0061 1 3 30 This page is intentionally blank...
Страница 46: ...CEM Systems 195 Airport Road West Belfast BT3 9ED United Kingdom Tel 44 0 2890 456767...