OPERATING INSTRUCTIONS 
Always  choose a  safe  location  for the  Dehumidifier, keeping  in mind  the safety  precautions  outlined. 
Ensure  all  packaging  has  been  removed  from  the  unit  before  use.  This  appliance  requires  no 
installation, it should be used solely as a portable appliance. 

 

WARNING Keep all objects at least 1 metre from the front, sides and rear of the appliance. 

 

Leave the appliance to stand for one hour after transport or after the unit has been on its side before 
connecting it to the mains supply to let the refrigerant settle. 

 

Ensure that the water container is positioned correctly. 

 

Ensure all external windows and doors are closed before turning on the unit. 

 

Plug into power supply and switch on at the mains.  The dehumidifier will display the current humidity 
level on the control panel. The POWER indicator light will illuminate to show power to the unit. 
To turn the Dehumidifier on, press the POWER button.  
Use the FAN SPEED button to switch between High and Low fan speeds. 

 

As long as the water container is not full, the Dehumidifier will continue to operate until it is switched 
off manually. 
If  the  Dehumidifier  is  switched  off  manually  and  then  switched  back  on,  the  compressor  will  start  to 
operate after three minutes. 

 

To turn the Dehumidifier off, press the POWER button. 

 

The  louvre  can  be  adjusted  manually  by  lifting  the  Louvre  at  the  opening  and  pushing  it  upward  or 
pressing it back down to closed. 

 

This Dehumidifier is designed to provide an optimum performance. It is not recommended to operate 

in ambient temperature exceeding 35

°C or Lower than 15°C. 

 

Press  the  HUMIDITY  SET  Button  to  set  the  desired  humidity  level  in  the  room,  each  press  of  the 
HUMIDITY SET button will adjust in 5% increments from 40-80%. 
Once you have set the desired humidity level, the LED will display the room humidity level again and 
will adjust as the room humidity level increases or decreases. 
When the relative humidity in the room is lower then the selected humidity, the unit will automatically 
stop dehumidifying until the humidity level increases again. 

 

TIMER OFF 
When the unit is operating press the TIMER button to set the length of time that you would like the unit 

to run for before turning off.  Each press of the TIMER button will adjust the length of time by 1 hour 

increments from 1 

– 24hours. To turn off the Timer function, set the Timer back to “00” hours or simply 

turn the unit off. 

 

TIMER ON 
When  the  unit is  Off  press  the  TIMER  button  to  set  the length of  time  that  you  would  like  the  unit to 
remain off before turning on. Each press of the TIMER button will adjust the length of time by 1 hour 
increments from 1 

– 24hours. To turn off the Timer function, set the Timer back to “00” hours or simply 

turn the unit on manually. 

 

WARNING! Take care in positioning your dehumidifier, using the timer will mean the unit will come on 

automatically.  Fire may result if placed next to combustible material. 

 

WATER TANK FULL 
A  beep  signal  will  sound  15  times.    The  WATER  FULL  indicator  light  will  illuminate  on  the  control 
panel.   
The compressor will stop automatically, and the unit will stop dehumidifying. 
Empty  the  water  container  and  replace  it  in  the  correct  position.    The  Dehumidifier  will  continue 
dehumidifying when the compressor automatically restarts after approximately three minutes. 

Содержание CELDH80

Страница 1: ...s rated to extract 8L per day in an environment of 80 humidity and temperature of 30 C This is the world wide standard for rating dehumidifiers In New Zealand we do not have climatic conditions with t...

Страница 2: ...appliance has been switched off 16 Do not remove plug from power socket by pulling cord always grip plug 17 Always unplug appliance when not in use 18 Do not locate the dehumidifier directly below any...

Страница 3: ...COMPONENTS Handle Air Outlet Shutters Front Cover Control Panel Power Cord Back Cover Air Filter Continuous Drainage Port Water Tank Back Cover Front Cover...

Страница 4: ...ceeding 35 C or Lower than 15 C Press the HUMIDITY SET Button to set the desired humidity level in the room each press of the HUMIDITY SET button will adjust in 5 increments from 40 80 Once you have s...

Страница 5: ...leaner to remove dust and fluff from around the grills Never use solutions such as benzene thinners or polishing agents Ensure the Dehumidifier is dry before plugging back into the mains supply TO CLE...

Страница 6: ...in low humidity or low temperatures The Dehumidifier operates but reduces the relative humidity in the room by small amounts The room which the Dehumidifier is operating in is too large Recommend usi...

Страница 7: ...that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are a...