background image

BIO X HD Camera Toolhead

User Manual

Содержание BIO X HD Camera Toolhead

Страница 1: ...BIO X HD Camera Toolhead User Manual...

Страница 2: ......

Страница 3: ...ad warnings 8 4 Getting started 9 4 1 Unpacking and installation 10 5 Initial calibration focusing and manual image capture 13 5 1 Your first image 14 5 2 Automated imaging during print 19 5 3 Removin...

Страница 4: ......

Страница 5: ...1 Package contents 01...

Страница 6: ...2 01 Package contents Item Part number Quantity HD Camera Toolhead D16110020853 1 Lens cap D16110020652 1 Observation pad D16110022041 1...

Страница 7: ...3 Technical specifications 02...

Страница 8: ...mum field of view 7 4 x 5 5 mm Dimensions height x width x depth 35 4 x 127 5 x 46 6 mm Connection BIO X toolhead mount and mini USB Weight 235 g Material composition External surfaces Powder coated s...

Страница 9: ...shown from the top and side view when using HD Camera Toolhead Movement range might be lower when combining the HD Camera Toolhead with a printhead that restricts printbox movement Please consult man...

Страница 10: ...6...

Страница 11: ...7 Safety information 03...

Страница 12: ...ually will damage the motor If the mount needs to be moved place the toolhead in the loading position described in the Getting Started section Use the proper method to load and unload the HD Camera To...

Страница 13: ...9 Getting started 04...

Страница 14: ...ob 2 Body 3 Lens cap Open the package Remove the HD Camera Toolhead Remove the lens cap from the HD Camera Toolhead To insert the toolhead align the toolhead above a mount Figure 3A B and push downwar...

Страница 15: ...11 04 Getting started Figure 3 Inserting the HD Camera Toolhead into a BIO X mount A B C D...

Страница 16: ...hing the micro USB to the BIO X printbox Make sure the camera light turns on after the toolhead clicks onto the mount Figure 3D Connect the mini USB cord to the mini USB port on the printbox to enable...

Страница 17: ...13 Initial calibration focusing and manual image capture 05...

Страница 18: ...pture 5 1 Your first image 1 Ensure the HD Camera Toolhead is properly installed Section 4 2 Insert a USB flash drive in the BIO X 3 Go to the Move and Calibrate tab on the right side of the screen an...

Страница 19: ...capture 4 Wait until the system has homed Ensure the HD Camera Toolhead is in the active position You can place the toolhead in the active position using the Tools tab on the Utilities menu Figure 6 F...

Страница 20: ...with printed text 6 Go to the Camera tab on the right side of the screen 7 Press the movement commands icon on the top right side of the video feed to display the movement arrows Figure 7 Figure 7 A...

Страница 21: ...ally adjust the focus knob until the target is in focus Figure 8A and B To focus objects closer to the camera turn the focusing knob to the right negative sign To focus objects further from the camera...

Страница 22: ...e an image 11 This image will be stored on the USB flash drive with the name bio x screen capture png 12 Repeated captures will be saved with numbers at the end of the file name NOTE To include a scal...

Страница 23: ...lhead is selected the Calibration tab will show the camera feed Figure 9 6 Position the toolhead in the desired print area and desired height above the construct The position should align with the oth...

Страница 24: ...20 05 Initial calibration focusing and manual image capture Figure 9 Calibration of the HD Camera Toolhead...

Страница 25: ...onnect the micro USB cable from the printbox to remove the HD Camera Toolhead Figure 10 2 Hold the mount in place with your hand and pull the toolhead up to remove it with the other hand See Section 3...

Страница 26: ...22...

Страница 27: ...23 Relevant G code commands 06...

Страница 28: ...seconds and P is the wait time in milliseconds G7 Xnnn Ynnn Znnn Fnnn When used in combination with the G90 command which defines absolute coordinates G7 is the relative move command The values for t...

Страница 29: ...image with a specific file name You can use the template below for writing a G code to take an image Please note that this is not a complete G code Tn sets HD Camera Toolhead in active position n is...

Страница 30: ...26...

Страница 31: ...27 Frequently asked questions 07...

Страница 32: ...materials at a time when using the HD Camera Toolhead on the BIO X Can it take real time images The HD Camera Toolhead can capture images at points defined by G code The functionality is more limited...

Страница 33: ...when capturing an image at the completion of a print Does it work independently or do I need to combine it with a printhead What if I want to image a previously printed construct The HD Camera Toolhea...

Страница 34: ...30...

Страница 35: ...31 Maintenance 08...

Страница 36: ...solvents or strong detergents to clean the toolhead Wipe it with a soft cloth slightly dampened in a mild soap and water solution Regularly clean the printhead to remove any dust or debris Keep the c...

Страница 37: ...33 Support information Official site Sales Store Support Official site www cellink com Contact support cellink com Contact sales cellink com Web store www cellink com store...

Страница 38: ...www cellink com...

Отзывы: