![Cellini CMF100 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/cellini/cmf100/cmf100_instruction-manual_2580395002.webp)
PRODUCT INTRODUCTION
The ultrasonic mist fan is designed with digital control
system. It has device for storing water. It can lower
surrounding temperature, freshen the air with equipped
ion humidify the air through the principle of water misting.
LED panel makes it easy to use.
IMPORTANT NOTES
Please read the instruction manual carefully before
operating this unit.
1. Make sure that the home power supply is consistent
with the product before plug in.
2. Switch off and disconnect from the power outlet
when not in use or before cleaning.
3. Do not expose the unit to rain and keep out of reach
of water on the control panel or LED for proper use.
4. Do not put the fingers or any objects inside the fan
grill during operation.
5. Do not operate the unit if there is any damage to the
power plug or cord - take the unit to an authorized
service agent for replacement; do not attempt to
undertake any required repairs yourself.
6. Wipe clean with damp cloth only - do not use any
abrasive cleaners.
7. This appliance is not intended for use by persons
(including children) with reduced physical, sensory,
or mental capabilities or lack of experience and
knowledge unless then have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
8. Do not use the misting function if the unit is to be
used in a damp place.
9. Do not use the misting mode when water tank is
empty; water level in must be above minimum level
for this function to operate, otherwise it may cause
water pump malfunction.
10. If the unit is being stored away for a long period of
time without use, empty the water tank before storing
or transporting the unit.
HOW TO ASSEMBLE THE WHEELS (SEE DRAWING 1)
1. Attach the four wheels to the base of the unit using
the included wrench (Feature No.32), tightening
each wheel in a clockwise direction.
2. Wheels can be
locked in position
if required.
WATER REFILL
1. Ensure the unit is placed on a level surface and
unplug from the power and switch off all the function
when refilling water.
2. Remove the water tank (Feature No. 24), fill water
tank to above minimum level indicator, but ensure
water is not overflowed.
3. Do not fill water above the Max water level mark
and misting function will not operate effectively if
water level is below minimum level.
MISTING FAN OPERATION - REMOTE & CONTROL PANEL
Make sure that the home power supply is consistent
with the product before plug in.
POWER ON/OFF OPERATION
Press the "fan power ON/OFF button"(Feature No. 15)
on the control panel or (Feature No.25) on the remote
controller to start operation, LED light (Feature No.8)
will become illuminated on the control panel. Press
the same button to turn off the function.
FAN SPEED OPERATION
Select the required fan speed to Low/Medium/High
by press the "Fan Speed Button"(Feature No.14) on
the control panel or (Feature No. 29) on the remote
control. LED light above selected speed will become
illuminated on the control panel.
OSCILLATION OPERATION
To start 360° air flow direction, press the "Fan
Oscillation Button" (Feature No. 13) on the control
panel or (Feature No. 26) on the remote controller once;
LED light(Feature No.4) will become illuminated on the
control panel, and the rotary fan grill will begin to rotate,
directing air in a full circle. Press the same button to
turn off the function.
1. Remove the
water tank and
fill clean water.
2. Tight the cover
in clockwise
direction.
4.
Put the water tank
back to the unit.
5. Press the “Fan
power ON/OFF”
button.
6. Select the Fan
Speed to start.
7. Press the “Misting
ON/OFF” to start
misting.
8. Adjust the mist density
by turning the “Misting
volume control”.
3. Turn the water
tank upside
down to make
sure no leaking.
Warning :
1. It may take a minute for a new Misting Fan to start
misting, it is normal for air to come out of the nozzles
before water and the mist.
2. Low Water Level Alarm : when water under lower
lever, you will hear the “beep” sound and the “Mist
Indicator” will flash continuously. At the same time
the power of the pump inside the unit will be cut off
to protect the life of the pump. To stop the alarm,
turn off the unit from the power outlet. Fill the tank
with water above the min.
level and turn on the unit
again.
3. Direct pull water into Misting
Fan is prohibited.
(SEE DRAWING 2)
REMOTE CONTROLLER
1. Open the remote control battery flap (Feature No.
31) and insert 2 pieces 1.5V "AAA" size of dry battery.
2. Remote controller must be aimed at the sensor
(Feature No. 16) on the front of the appliance,
distance within 5 meters, and will not function
from beside or behind the appliance.
CLEANING AND MAINTENANCE (SEE DRAWING 3)
1. Ensure the unit is switched off and disconnected
from a power source before cleaning.
2. Clean outer casing or control panel with a damp
cloth only - do not use any abrasive cleaners or
harsh chemicals, and ensure the control panel or
LED is out of reach of water.
3. Check the condition of misting and water tank before
every use.
4. After long time operation with this appliance, the
unit may become clogged with dust and dirt, which
will greatly affect the performance of the unit.
Sometimes mold and mildew may also occur due
to the water tank not regular cleaned, recommend
to clean once every two weeks.
5. Remove the drain plug (Feature No. 21) and allow
the water tank to empty.
6. If the unit is being stored away for a long period
of time without use, empty the water tank before
storing or transporting the unit.
TECHNICAL SPECIFICATIONS
Input Voltage ............................ 220-240V 50/60Hz
Input Power..................................................100W
Operating Temperature.............................. 0ºC-45ºC
Operating Humidity ........................ Lower than 90%
Fan Maximum Air Volume .................. > 300M
3
/Hour
Fan Maximum Speed................................... 5.5m/s
Motor Speed...High 1400/Med. 1340/Low 1220RPM
Water Tank Capacity ................................... 4 Liters
Evaporative Contant Of Wate .........Approx 300mL/Hz
Ion Density Approx........................... 3x106 Ion/cm
3
Timer Control.......................................... 1-8 Hours
Remote Controller Battery .............(AAA) 1.5V × 2pcs
Remote Control Distance................................... 5 m
Dimensions.................... Approx 41 × 23.5 × 81cm
N.W ................................................Approx 5.75kg
DRAWING 3
DRAWING 2
DRAWING 1
MIN
MAX
IONIZER OPERATION
Press the "Ionizer Button" (Feature No. 10) on the control
panel or (Feature No. 30) on the remote controller once
to release the anions. Illuminated light is on the control
panel will indicate function is currently in operation.
Press the same button to turn the function off.
TIMER OPERATION
1. Press the "Timer Button" (Feature No. 9) on the
control panel or (Feature No. 28) on the remote
controller to set the countdown timer. The unit will
operate with its present settings until the timer
counts down.
2. Timer can be set from 1 to 8 hours.
3. Once set, LED display will show the time set.
4. To switch off the timer function and operate the
unit continuously, press the timer button until LED
display switches off and the LED light on the control
panel above timer button LED will also be off.