PRODUCT INTRODUCTION

The ultrasonic mist fan is designed with digital control 
system. It has device for storing water. It can lower 
surrounding temperature, freshen the air with equipped 
ion humidify the air through the principle of water misting. 
LED panel makes it easy to use.

IMPORTANT NOTES

Please read the instruction manual carefully before
operating this unit.
1.  Make sure that the home power supply is consistent 
 

with the product before plug in.

2.  Switch off and disconnect from the power outlet
 

when not in use or before cleaning.

3.  Do not expose the unit to rain and keep out of reach 
 

of water on the control panel or LED for proper use.

4.  Do not put the fingers or any objects inside the fan 
 

grill during operation.

5.  Do not operate the unit if there is any damage to the 
 

power plug or cord - take the unit to an authorized 

 

service agent for replacement; do not attempt to 

 

undertake any required repairs yourself.

6.  Wipe clean with damp cloth only - do not use any 
 

abrasive cleaners.

7.  This appliance is not intended for use by persons 
 

(including children) with reduced physical, sensory, 

 

or mental capabilities or lack of experience and 

 

knowledge unless then have been given supervision 

 

or instruction concerning use of the appliance by a 

 

person responsible for their safety.

8.  Do not use the misting function if the unit is to be
 

used in a damp place.

9.  Do not use the misting mode when water tank is
 

empty; water level in must be above minimum level 

 

for this function to operate, otherwise it may cause 

 

water pump malfunction.

10. If the unit is being stored away for a long period of 
 

time without use, empty the water tank before storing 

 

or transporting the unit.

HOW TO ASSEMBLE THE WHEELS (SEE DRAWING 1)

1.  Attach the four wheels to the base of the unit using 
 

the included wrench (Feature No.32), tightening 

 

each wheel in a clockwise direction.

2.  Wheels can be 
 

locked in position 

 

if required.

WATER REFILL

1.  Ensure the unit is placed on a level surface and

 

unplug from the power and switch off all the function 

 

when refilling water.

2.  Remove the water tank (Feature No. 24), fill water

 

tank to above minimum level indicator, but ensure

 

water is not overflowed.

3.  Do not fill water above the Max water level mark

 

and misting function will not operate effectively if

 

water level is below minimum level.

MISTING FAN OPERATION - REMOTE & CONTROL PANEL

Make sure that the home power supply is consistent

with the product before plug in.

POWER ON/OFF OPERATION

Press the "fan power ON/OFF button"(Feature No. 15)

on the control panel or (Feature No.25) on the remote

controller to start operation, LED light (Feature No.8)

will become illuminated on the control panel. Press

the same button to turn off the function.

FAN SPEED OPERATION

Select the required fan speed to Low/Medium/High

by press the "Fan Speed Button"(Feature No.14) on

the control panel or (Feature No. 29) on the remote

control. LED light above selected speed will become

illuminated on the control panel.

OSCILLATION OPERATION

To start 360° air flow direction, press the "Fan 

Oscillation Button" (Feature No. 13) on the control 

panel or (Feature No. 26) on the remote controller once; 

LED light(Feature No.4) will become illuminated on the 

control panel, and the rotary fan grill will begin to rotate, 

directing air in a full circle. Press the same button to 

turn off the function.

1.  Remove the 

  water tank and 

  fill clean water.

2.  Tight the cover 

  in clockwise 

  direction.

4. 

Put the water tank 

  back to the unit.

5.  Press the “Fan 

  power ON/OFF”

  button.

6.  Select the Fan 

  Speed to start.

7.  Press the “Misting 

  ON/OFF” to start 

  misting.

8.  Adjust the mist density 

  by turning the “Misting 

  volume control”.

3.  Turn the water 

  tank upside 

  down to make 

  sure no leaking.

Warning :

1.  It may take a minute for a new Misting Fan to start 

 

misting, it is normal for air to come out of the nozzles 

 

before water and the mist.

2.  Low Water Level Alarm : when water under lower 

 

lever, you will hear the “beep” sound and the “Mist 

 

Indicator” will flash continuously.  At the same time 

 

the power of the pump inside the unit will be cut off 

 

to protect the life of the pump.  To stop the alarm, 

 

turn off the unit from the power outlet.  Fill the tank 

 

with water above the min. 

 

level and turn on the unit 

 

again.

3.  Direct pull water into Misting 

 

Fan is prohibited.

 

(SEE DRAWING 2)

REMOTE CONTROLLER

1.  Open the remote control battery flap (Feature No.

 

31) and insert 2 pieces 1.5V "AAA" size of dry battery.

2.  Remote controller must be aimed at the sensor

 

(Feature No. 16) on the front of the appliance,

 

distance within 5 meters, and will not function

 

from beside or behind the appliance.

CLEANING AND MAINTENANCE (SEE DRAWING 3)

1.  Ensure the unit is switched off and disconnected
 

from a power source before cleaning.

2.  Clean outer casing or control panel with a damp
 

cloth only - do not use any abrasive cleaners or

 

harsh chemicals, and ensure the control panel or

 

LED is out of reach of water.

3.  Check the condition of misting and water tank before
 

every use.

4.  After long time operation with this appliance, the
 

unit may become clogged with dust and dirt, which 

 

will greatly affect the performance of the unit. 

 

Sometimes mold and mildew may also occur due 

 

to the water tank not regular cleaned, recommend 

 

to clean once every two weeks.

5.  Remove the drain plug (Feature No. 21) and allow
 

the water tank to empty.

6.  If the unit is being stored away for a long period
 

of time without use, empty the water tank before

 

storing or transporting the unit.

TECHNICAL SPECIFICATIONS

Input Voltage ............................ 220-240V 50/60Hz
Input Power..................................................100W
Operating Temperature.............................. 0ºC-45ºC
Operating Humidity ........................ Lower than 90%
Fan Maximum Air Volume .................. > 300M

3

/Hour

Fan Maximum Speed................................... 5.5m/s
Motor Speed...High 1400/Med. 1340/Low 1220RPM
Water Tank Capacity ................................... 4 Liters
Evaporative Contant Of Wate .........Approx 300mL/Hz
Ion Density Approx........................... 3x106 Ion/cm

3

Timer Control.......................................... 1-8 Hours
Remote Controller Battery .............(AAA) 1.5V × 2pcs
Remote Control Distance................................... 5 m
Dimensions.................... Approx 41 × 23.5 × 81cm
N.W ................................................Approx 5.75kg

DRAWING 3

DRAWING 2

DRAWING 1

MIN

MAX

IONIZER OPERATION

Press the "Ionizer Button" (Feature No. 10) on the control 

panel or (Feature No. 30) on the remote controller once 

to release the anions. Illuminated light is on the control 

panel will indicate function is currently in operation. 

Press the same button to turn the function off.

TIMER OPERATION

1.  Press the "Timer Button" (Feature No. 9) on the 

 

control panel or (Feature No. 28) on the remote 

 

controller to set the countdown timer. The unit will 

 

operate with its present settings until the timer 

 

counts down.

2.  Timer can be set from 1 to 8 hours.

3.  Once set, LED display will show the time set.

4.  To switch off the timer function and operate the

 

unit continuously, press the timer button until LED

 

display switches off and the LED light on the control

   panel above timer button LED will also be off. 