Using a #2 Phillips screw driver, loosen the PEM 

hardware securing the grille to the base.

Note: Use caution as plenum will not be 

supported once screws are removed.

Remove plenum from unit and set aside.

Remove thumb screw securing electrical panel 

in place.

Slide electrical panel down and place hooks in 

electrical slots to hold in place.

3

4

5

6

Содержание RTN400

Страница 1: ... Split Series 091018 24V Thermostat Conversion Kit to be used in conjunction with Fully Ducted Split Series CONFIDENTIAL Fully Ducted Split Series 24V THERMOSTAT CONVERSION KIT Installation Manual RTN400 XW260K ...

Страница 2: ...te CellarCool is not responsible for printing or clerical errors CellarCool reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice Vinothèque and CellarCool are registered trademarks and ECE is a trademark of CellarCool All rights reserved Mention of third party products is for informational purposes only and consti...

Страница 3: ...www cellarcool com Page 1 TABLE OF CONTENTS Receiving Inspecting the Kit 3 Before You Start 4 24V Thermostat Conversion Kit Installation Instructions 5 ...

Страница 4: ...ead and review this manual carefully and keep it for future reference What is a 24V Thermostat Conversion Kit The 24V Thermostat Conversion Kit is a CellarCool product that allows the customer to switch from the provided standard 120V controller to a 24V thermostat of their choosing i e Nest Ecobee Honeywell etc Note 24V Thermostat not provided by CellarCool How Does the 24V Thermostat Conversion ...

Страница 5: ...hermostat Conversion Kit Inspect the packaging for any obvious signs of damage or mishandling before opening the container Note any discrepancies or visual damage on the bill of lading before signing Review the packing slip to verify contents Check the model number to ensure it is correct If any items listed on the packing slip do not match your order information contact CellarCool Customer Servic...

Страница 6: ...ondensing unit WARNING Failure to disconnect the power may cause electrical shock which can result in injury or death Note If the unit is hard wired to a dedicated power source shut off the designated breaker These instructions are universal for both the RTN400 XW260K controllers If your controller model is RTN400 skip the steps labeled XW260K ONLY If your controller model is XW260K skip the steps...

Страница 7: ...er loosen the PEM hardware securing the grille to the base Note Use caution as plenum will not be supported once screws are removed Remove plenum from unit and set aside Remove thumb screw securing electrical panel in place Slide electrical panel down and place hooks in electrical slots to hold in place 3 4 5 6 ...

Страница 8: ...the 4 screws from the enclosure lid using a 1 Phillips screw driver RTN400 ONLY Locate Pb1 Pb2 DI and Display wires RTN400 ONLY Disconnect Pb2 DI Display and Pb1 wires from the circuit board RTN400 ONLY Remove the disconnected wires from the enclosure 7 8 9 10 ...

Страница 9: ...es circled in red pb1 pb2 display wires XW260K ONLY Disconnect Pb1 Display and Pb2 wires from the circuit board XW260K ONLY Remove the rubber grommet and disconnected wires from the enclosure XW260K ONLY Use wire cutters to remove the grommet 11 12 13 14 ...

Страница 10: ...s screws securing the enclosure to the panel using a 2 Phillips screw driver Separate controller assembly from the unit Controller assembly is no longer needed Isolate previously removed wires and secure with the provided cable tie Note these wires will no longer be used however they need to stay with unit 15 16 17 18 ...

Страница 11: ...ermostat wire into electrical compartment as shown Note cork tape will need to be moved aside to slide wire through Route 18 5 thermostat wire down to the location shown on the electrical panel Strip off 6 from the thermostat wire casing Cut and remove white thermostat wire Strip off about of the blue red green and yellow thermostat wire casing to expose the copper 19 20 21 22 REAR OF UNIT BOTTOM ...

Страница 12: ...here the previous controller box was mounted Mount the 24V Conversion Kit Enclosure in the location shown using the previously removed Phillips screws Connect thermostat wires with the provided wire nuts by color matching red to red blue to blue green to green and yellow to yellow Secure thermostat wires as shown using cable ties 23 24 25 26 ...

Страница 13: ...cure electrical panel in place 30 Place the provided adhesive backed cable tie mount in the location shown on the box Secure wires to cable tie mount using cable tie Slide electrical panel into compartment Secure wires into electrical compartment 27 28 29 ...

Страница 14: ...Page 12 1 800 343 9463 24VTCK FD Split Series 091018 Reinstall grille Conversion process is now complete 31 The 24V Thermostat Conversion Kit has been successfully installed ...

Страница 15: ...24VTCK FD Split Series 091018 CellarCool 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www CellarCool com ...

Отзывы: