Cell2 SDA100W Скачать руководство пользователя страница 7

- 6 -

● Positive and Negative Horn Ring Transfer (HRT) Switching

    

Carefully check and change the DIP Switch #6 according to your reve or -ve switching.

  Restart the unit after setting to apply the change.

  DIP Switch #1 to #5 is for Tone setting; see next page.

For +ve switching HRT:

1

ON

DIP

2

3

4

5

6

1

ON

DIP

2

3

4

5 6

For -ve switching HRT:

ON

1 2 3 4 5 6

DIP

DIP Switch

No. COUNTRY

TONE

CYCLE/MINUTE

MIX TONE

DISABLE/ ENABLE 

DAY/NIGHT WIRE

ENABLE HRT,

SIREN ON,

INTERLOCK ON

ENABLE HRT,

SIREN OFF,

INTERLOCK OFF

ENABLE HRT,

SIREN OFF,

INTERLOCK ON

1

USA/ UK

STANDARD

YELP 157 C/M

TWO TONE 40 C/M

WAIL 12 C/M

DAY/NIGHT

YELP

TWO TONE

WAIL

AIR HORN

AIR HORN

YELP

2

FRANCE

GENDAMERIE

TWO TONE 54 C/M

DAY/NIGHT

AIR HORN

AIR HORN

TWO TONE

TWO TONE

3

FRANCE

POLICE

TWO TONE 54 C/M

DAY/NIGHT

AIR HORN

AIR HORN

TWO TONE

TWO TONE

4

FRANCE

AMBULANCE

TWO TONE 30 C/M

DAY/NIGHT

AIR HORN

AIR HORN

TWO TONE

TWO TONE

5

FRANCE

POMPIERS

TWO TONE 27 C/M

DAY/NIGHT

AIR HORN

AIR HORN

TWO TONE

TWO TONE

6

FRANCE

UMH

TWO TONE 54 C/M

DAY/NIGHT

AIR HORN

AIR HORN

TWO TONE

TWO TONE

8

AUSTRIA

POLICE

TWO TONE 25 C/M

DAY/NIGHT

N/A

N/A

TWO TONE

TWO TONE

9 AUSTRIA

AMBULANCE

TWO TONE 17 C/M

DAY/NIGHT

N/A

N/A

TWO TONE

TWO TONE

10 AUSTRIA FIRE BRIGADE TWO TONE 17 C/M

DAY/NIGHT

N/A

N/A

TWO TONE

TWO TONE

11

AUSTRIA

MAGISTRATE

TWO TONE 18 C/M

DAY/NIGHT

N/A

N/A

TWO TONE

TWO TONE

12

ITALY

POLICE

TWO TONE 20 C/M

DAY/NIGHT

AIR HORN

AIR HORN

TWO TONE

TWO TONE

13

ITALY

AMBULANCE

DAY/NIGHT

AIR HORN

AIR HORN

TWO TONE

TWO TONE

TWO TONE 20 C/M

WAIL

14

ITALY

AMBULANCE 2

WAIL 12 C/M

DAY/NIGHT

YELP

TWO TONE

WAIL

AIR HORN

TWO TONE

YELP

TWO TONE 20 C/M

YELP 157 C/M

TWO TONE

YELP 157 C/M

DAY/NIGHT

YELP

15

USA/ UK

STANDARD 2

WAIL 12 C/M

YELP

TWO TONE

WAIL

AIR HORN

AIR HORN

YELP

TWO TONE 40 C/M

TWO TONE

7

GERMANY

COUNTRY(LAND)

CITY(STADT)

TWO TONE 40 C/M

AIR HORN

AIR HORN

TWO TONE

TWO TONE

TWO TONE 40 C/M

STADT/LAND

TWO TONE

TWO TONE

TWO TONE

WAIL

TONE TABLE

To change the Tone Group, see next page for corresponding DIP Switch setting.

DIP SWITCH SETTING

 

DIP Switch Location

Содержание SDA100W

Страница 1: ...SDA100W Siren Amplifier NOTICE TO INSTALLER Before installation and operation read all instructions and warnings Deliver this manual to the end user of this product Installation Operation Manual...

Страница 2: ...s in the manual from the original manufacturer 6 The operator should verify the siren system is fastened to the vehicle securely and is functioning properly Failure to follow all safety precautions an...

Страница 3: ...24VDC Siren Output Power 100 Watts Output Load 100W ACR 11 Siren Frequency 759Hz 1592Hz Max Current 9A 12VDC 4 5A 24VDC Standby Current 0 mA w o IGN wire 0 2A w IGN wire Operating Temperature Range 20...

Страница 4: ...ounting holes for sheet metal screw 4 Install the siren amplifier with provided sheet metal screws and tooth lock washers Microphone clip 1 Select a location where is convenient to the operator avoid...

Страница 5: ...the top right corner of the mic will adjust the mic volume high or low Turn clockwise for high volume turn anticlockwise for low volume MIC I O FUSE POWER Microphone RJ45 Connector Connector A BLACK P...

Страница 6: ...ve differently For actual function of this wire see page 6 for Tone Table When the Siren Tone is activated Apply VDC continuously to PINK wire for Air Horn tone until the wire is released Base on the...

Страница 7: ...NE 27 C M DAY NIGHT AIR HORN AIR HORN TWO TONE TWO TONE 6 FRANCE UMH TWO TONE 54 C M DAY NIGHT AIR HORN AIR HORN TWO TONE TWO TONE 8 AUSTRIA POLICE TWO TONE 25 C M DAY NIGHT N A N A TWO TONE TWO TONE...

Страница 8: ...USA UK STANDARD FRANCE GENDAMERIE FRANCE POLICE FRANCE AMBULANCE FRANCE POMPIERS FRANCE UMH GERMANY CITY STADT COUNTRY LAND AUSTRIA POLICE AUSTRIA AMBULANCE AUSTRIA FIRE BRIGADE AUSTRIA MAGISTRATE IT...

Отзывы: