background image

p.5

Product warranty information can be found on our Celerity website at 
www.Celerity.net. This information provides general warranty information, limita-
tions, disclaimers, and applicable warranty periods according to product group.

4.0

_WARRANTY

For technical assistance, contact Celerity Technical Support at 972.359.4000.

Celerity is a trademark of Celerity of Celerity, Inc. All other product or service names mentioned in this document 
may be trademarks of the companies with which they are associated. System descriptions are typical and subject 
to change without notice.

©2007 Celerity, Inc.                        A331289 Rev. 001                         08/07

CELERITY, INC.
915 Enterprise Boulevard
Allen, TX 75013 USA
Telephone  972.359.4000
Facsimile  972.359.4100
www.celerity.net

Содержание Surface Line Rotatable Series

Страница 1: ...Surface Line Rotatable SLR Series Pressure Transducer Display User Guide Celerity Inc 915 Enterprise Boulevard Allen TX 75013 USA T 1 972 359 4000 F 1 972 359 4100 A331289 REV 001 8 07 ...

Страница 2: ... _2 1 OPERATING SPECIFICATIONS 2 _3 0 INSTALLATION 3 _3 1 SLR PRESSURE TRANDUCER DISPLAY DIMENSIONAL DRAWING PINOUTS 3 _3 2 MECHANICAL INSTALLATION 4 _3 3 ELECTRICAL CONNECTION 4 _3 4 DISPLAY ALIGNMENT 4 _3 5 MODE SETTING 4 _3 6 CALIBRATION 4 _3 7 REMOVAL AND REPLACEMENT 4 _4 0 WARRANTY 5 _CONTENTS ...

Страница 3: ...rface substrate It is designed to interface via 15 Pin D connector to SS2 transducers with 30 and 100 PSI full scale pressure ranges The SLR utilizes a 3 5 segment light emitting diode LED with two selectable engineering units PSIA and KPa and can be rotated to be positioned at all four quadrants The SLR is electrically interfaced using a standard high density 15 pin D Sub HD15P connector The devi...

Страница 4: ...ay Count Thermal Sensitivity 0 2 Display Counts C Operating Conditions Range 30 PSI 207 KPa 100 PSI 689 KPa Temperature Range 30 to 140 F 0 to 60 C Visual Display 290 Total Rotation Electrical Power Requirements Current Powered 3 92 20 4 mADC Voltage Powered 13 0 to 32 VDC Output 3 1 2 Digit Red 7 Segment LED 0 30 7 6mm High Input Requirements 0 5 VDC 0 10 VDC 4 20mA Minimum 4 95 9 9 3 92mADC Typi...

Страница 5: ...ed 2 Pressure Signal 2 Pressure Signal 7 Power Input 7 Power Input 5 121 Power Supply Common Signal Common 5 121 Power Supply Common Signal Common Current Mode Pinout DB15 MALE PIN NUMBER SIGNAL DB15 FEMALE PIN NUMBER SIGNAL 1 2 3 4 6 8 9 15 Not Used 1 2 3 4 6 8 9 15 Not Used 7 Pressure Signal 7 Pressure Signal 5 121 Signal Common 5 121 Signal Common 47 75 1 88 30 48 1 20 28 58 1 13 Ø 28 58 1 13 P...

Страница 6: ...can be switched from or to either PSIA or KPa Full scale pressure range is factory set Refer to the part number for the range of the unit installed 3 6 CALIBRATION Calibration is not required for the SLR Pressure Transducer Display The pres sure transducer potentiometers should be used to adjust the zero of the pres sure transducer 3 7 REMOVAL AND REPLACEMENT 1 Remove power to the display 2 Discon...

Страница 7: ...ance contact Celerity Technical Support at 972 359 4000 Celerity is a trademark of Celerity of Celerity Inc All other product or service names mentioned in this document may be trademarks of the companies with which they are associated System descriptions are typical and subject to change without notice 2007 Celerity Inc A331289 Rev 001 08 07 CELERITY INC 915 Enterprise Boulevard Allen TX 75013 US...

Отзывы: