Celectron Audio WD10A Скачать руководство пользователя страница 9

CE CONFORMITY

CELECTRON

 products comply with directive EMC 2014/30/CE, as stated in EN 55103-1 and EN 55103-2 standards and with directive LVD

2014/35/CE,

 

as stated in EN 60065 standard.

• Under the EM disturbance, the ratio of signal-noise will be changed above 10dB.

PACKAGING, SHIPPING AND COMPLAINT

• This unit package has been submitted to ISTA 1A integrity tests. We suggest you control the unit conditions immediately after unpacking it.

• If any damage is found, immediately advise the dealer. Keep all unit packaging parts to allow inspection.

CELECTRON

 is not responsible for any damage that occurs during shipment.

• Products are sold “delivered ex warehouse” and shipment is at charge and risk of the buyer.

• Possible damages to unit should be immediately notified to forwarder. Each complaint for package tampered with should be done within eight

days from product receipt.

WARRANTY AND PRODUCTS RETURN

CELECTRON

 products have operating warranty and comply their specifications, as stated by manufacturer.

CELECTRON

 warrants all materials, workmanship and proper operation of this product for a period of two years from the original date of

purchase. If

 

any defects are found in the materials or workmanship or if the product fails to function properly during the applicable warranty

period, the owner

 

should inform about these defects the dealer or the distributor, providing receipt or invoice of date of purchase and defect

detailed description.

 

This warranty does not extend to damage resulting from improper installation, misuse, neglect or abuse. 

CELECTRON

Electronic

 will verify damage on returned

 

units, and when the unit has been properly used and warranty is still valid, then the unit will be replaced

or repaired. 

CELECTRON

 Electronic

 is not responsible

 

for any "direct damage" or "indirect damage" caused by product defectiveness.

INSTALLATION AND DISCLAIMER

CELECTRON

 products have been expressly designed for audio application, with signals in audio range (20Hz to 20kHz). 

CELECTRON

 has no liability

for damages

 

caused in case of lack of maintenance, modifications, improper use or improper installation non-applying safety instructions.

• The installation of these speakers is provided for indoors, in case of use outdoors be sure that the speakers are installed correctly in a safe

location protected from wind, rain and humidity. To avoid  performance deterioration of mechanical, acoustics and electrical parts is not advisable

to leave these speakers exposed outdoors for a long period of time, so we suggest a temporary installation for the limited sound events.

• The installation of these speakers is provided for floor or by means of specific stands able to support their weight. Therefore avoid installation

on unstable elements such as: furniture, chairs and vibrant surfaces as stages or other speakers without appropriate fix point specifically designed

to avoid speaker movement. Then avoid the use of inadequate supports, we suggest to use 

CELECTRON

 stands and accessories only.

• In case of the speakers are provided of rigging points: DO NOT SUSPEND THE SPEAKERS FROM THE HANDLES, use exclusively these rigging points.

Consult professional rigger or structural engineers prior to suspending loudspeakers from a structure not intended for that use. Always know the

working load limit of the structure supporting the loudspeakers. Always make sure that the rigging hardware minimum rating is at least five times

the actual load, speakers and rigging hardware.

• In case of suspended installations of active loudspeakers where is not possible to turn on and off the speakers from their appropriate switches,

we recommend to install switches on the mains lines, for this purpose consult an expert electrician for the exact dimension of wiring.

• Locate the speakers as far away as possible from radio or television receivers or other sensitive equipment. These speakers have a strong

magnetic field which can induce hum and noise into unshielded devices that are located nearby with consequent deterioration of reception of

image and sound.

CELECTRON

 

Electronic

 reserves the right to change these specifications at any time without notice.

CELECTRON

 

Electronic

 declines any liability for damages to objects or persons caused by lacks of maintenance, improper use, installation not

performed

 

with safety precautions and at the state of the art.

POWER SUPPLY AND MAINTENANCE

• Clean only with dry cloth.

• Check periodically that the slots for its proper ventilation and heating dissipation are not obstructed by dust, remove the dust using a dry brush

or a compressed air gun.

• The amplified loudspeakers of 

CELECTRON

 have been designed with CLASS I construction and must be connected always to a mains socket

outlet with

 

a protective earth connection (the third grounding prong).

• Before connecting the product to the mains outlet make certain that the mains line voltage matches that shown on the rear of the product, a

tolerance of up to ±10% is acceptable.

• Inside the amplified loudspeakers are present special safety devices such as:

ü

Transformer and amplifier over-heating protection.

ü

Protection against excessive power applied at each speaker.

THE REPLACEMENT OF FUSES INSIDE THE APPARATUS MUST BE MADE ONLY BY QUALIFIED PERSONNEL.

 

CHECK THE CONDITION OF THE PROTECTION FUSE, ACCESSIBLE OUTWARD, ONLY WITH THE APPARATUS SWITCHED OFF AND

DISCONNECTED

 

FROM THE MAINS LINE OUTLET.

REPLACE THE PROTECTION FUSE ONLY WITH SAME TYPE AS SHOWN ON THE PRODUCT.

IF AFTER THE SUBSTITUTION, THE FUSE INTERRUPTS AGAIN THE APPARATUS WORKING, DO NOT TRY AGAIN THEN CONTACT THE

CELECTRON

 

SERVICE CENTRE.

Содержание WD10A

Страница 1: ...WD10A WD12A WD15A Active Floor Monitors USER MANUAL ...

Страница 2: ...terature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purcha...

Страница 3: ... INDEX 2 3 4 5 6 6 7 8 8 8 9 9 9 9 9 10 10 DIMENSIONS WD10A WD12A WD15A 37 5 cm 14 7 49 0 cm 19 3 26 5 cm 10 4 44 0 cm 17 3 51 0 cm 20 1 31 0 cm 12 2 49 0 cm 19 3 60 0 cm 23 6 33 5 cm 13 2 ...

Страница 4: ...ivity Controls Connectors Power Supply Maximum Consumption Rated Consumption Construction Pole Adapter Handles Monitor taper Weight Dimensions W x H x D 0 dBu LEVEL PRESET selector MONITOR FOH GND lift IN COMBO XLR JACK LINK XLR 230 VAC or 120 VAC 50 60 Hz 365 W 215 W Plywood with black anti scratch polyurethane paint 1 x side 2 x sides 36 12 kg 26 4 lb 490 x 265 x 375 mm 0 dBu LEVEL PRESET select...

Страница 5: ...A preset MONITOR WD10A preset FOH WD12A preset MONITOR WD12A preset FOH 10k 5k 2k 1k 500 200 100 50 40 20k Hz 20 dB 10 0 10 20 30 10k 5k 2k 1k 500 200 100 50 40 20k Hz 20 dB 10 0 10 20 30 WD15A preset MONITOR WD15A preset FOH 10k 5k 2k 1k 500 200 100 50 40 20k Hz 20 dB 10 0 10 20 30 10k 5k 2k 1k 500 200 100 50 40 20k Hz 20 dB 10 0 10 20 30 ...

Страница 6: ... INPUT Balanced male XLR ground hot cold INPUT Jack unbalanced ground tip hot cold note connect both cold and ground to make cable from balanced to unbalanced 2 1 2 1 20mm 0 8 8mm 0 3 RED BLACK negative black nero 1 n c LINK output Balanced female XLR ground hot cold 4 5 6 7 8 9 1 2 3 10 11 ...

Страница 7: ...TION EXAMPLES FIG 3 From mixer From mixer WD15A SW115HA single monitor WD10 12 15A doubled monitor WD10 12 15A preferably use the same model stage Floor monitoring Drum fill monitoring SET THE EQ PRESET ON MONITOR ...

Страница 8: ...quipment capable of producing high sound pressure levels use hearing protectors while the equipment is in operation Ear plugs or protectors in the ear canals or over the ears must be worn when operating the equipment in order to prevent permanent hearing loss if exposure is in excess of the limits set forth here Keep your s attention that children and pets are more susceptible to excessive noise l...

Страница 9: ...efore avoid installation on unstable elements such as furniture chairs and vibrant surfaces as stages or other speakers without appropriate fix point specifically designed to avoid speaker movement Then avoid the use of inadequate supports we suggest to use CELECTRON stands and accessories only In case of the speakers are provided of rigging points DO NOT SUSPEND THE SPEAKERS FROM THE HANDLES use ...

Страница 10: ...ce for vocals guitar horns and electronic instruments or as a high power monitor for DJs WD15A with its full extension and powerful and deep response at the low frequencies is the ideal monitor for bass and drums players The horn loaded HF section and the powerful amplifier make it the perfect solution for monitoring also on very large stages INPUT AND CONTROL INSTRUCTIONS FIG 1 2 3 1 LINE IN comb...

Страница 11: ... that the amplifier has been turned on and AC power is available 9 LINE VOLTAGE selector This switch sets the AC voltage line of your country usually it is set by factory and isn t necessary to change it The 115V setting is for mains line in the range of 105 120V and 230V setting is for mains line in the range of 210 240V WARNING an incorrect setting of AC LINE VOLTAGE could damage seriously the i...

Страница 12: ...Celectron Electronic Group BBFY Industrial USA Inc City of Industry California www celectronaudio com ...

Отзывы: