Celect SAS908XWHB-7-DF1 Скачать руководство пользователя страница 10

 

 10

2.

 

Permanent hold temperature setting 

     

When thermostat is in program operation, press butto

n ①

  over 3 seconds to enter the Permanent hold   

mode . Press 

▲、▼

  change set temperature. The thermostat will permanent hold the room temperature at the 

selected setting until you press 

  button to restart    the program operation.   

 

3.

 

Code match and Wireless Control

 

 

1) According to the system requirements SAS2010DE connected to the power source (L, N 100 ~ 240 vac), 

Check and energizing, Press the power button switch machine is normal or not electricity, light is lit. 
Otherwise, Please replace the product, Then press the last step action to execute.   

 
2) Open SAS908XWHB-7-DF1 backplane Load two batteries (AA) 

Closed the backplane, And check the 

display and button functions, not normal replacement product, Press re-execute the previous step action. 

 
(3) Energized normal SAS2010DE products in shutdown mode (indicator), press and hold the power button 

until the indicator A long bright yellow release, this time SAS2010DE in the code state. 

 
(4) The thermostat SAS908XWHB -7- DF1 in standby mode, long according to the thermostat 

button 

more than 3 seconds, Emission to code command.   

 
(5) The success of the code receiving portion yellow flashing 01 blinks four times, Otherwise the code is 

unsuccessful, Return reflector of the original code value. 

 

Note: When in the process for the debug on/off, the interval of time should more than 4 sec, 

otherwise the products have not time for react. 

 

4.

 

Reset operation 

If the display is abnormal, press the Reset button by using a fine probe such as a straightened paper 

clip to gently push the Rest button. This will reset the thermostat. 

 

5.

 

 

Battery note

: 1)The battery power low battery warning sign "

" flicker 

                              2) Products when not in use for a long time, please take off, to prevent battery leakage 

damage product   

 

 

 

 

 

CUSTOMER ASSISTANCE 

After reading this guide, if you have any question about the operation of your thermostat, please contact your 

installer or service provider.   

Содержание SAS908XWHB-7-DF1

Страница 1: ...ere in the home to detect and control the temperature of an area of the user s choice Not limited by power control wiring locations Link with the Receiver via RF Control distance 100M open site Large LCD display The screen displays the set temperature and the room temperature also time simultaneously Permanent user setting and program setting retention during power loss Optional temperature displa...

Страница 2: ...next item Confirm Exit button At setting state shortly press button is all setting confirmation and exit forever keeping mode or at temporarily keeping mode shortly press button to exit and return to program running state at parameter setting or program setting long press button more than 3 seconds parameter setting or program setting return to factory default setting At power on anti freezing mod...

Страница 3: ...ut the thermostat will have room ERR display 3 Communication alarm When the thermostat stops or starts the output the receiver do not start or not receive some signals that can not return to the thermostat display will show Er2 OUTPUT REGULATION Press to shift standby or running mode Standby mode OFF mode The system has no output or Temperature lower than the low limitation LO alarm Running mode h...

Страница 4: ...s 1 Press P Button Select temperature display adjustment higher or lower 2 Press P Button Select maximum room temperature limitation 3 Press P Button Select minimum room temperature limitation 4 Press P Button Changes the display readout to Centigrade or Fahrenheit as required 5 Press P Button Backlight mode no backlight backlight maintain 5 sec backlight maintain 15 sec 6 Press P Button Start hea...

Страница 5: ...orever keeping mode shortly press button enter modify the time shortly press button enter programming state and exit forever keeping mode shortly press button exit forever keeping mode shortly press modify the setting temperature C without programming mode running shortly press enter off mode shortly press button enter modify the time shortly press modify the setting temperature D In temporarily k...

Страница 6: ... to select setting you want Press quit In the programming surface push button in a same time for 3 seconds Display will show DEF blinking 3 times and return to programming setting 1 indicates all the setting has reverted to factory default setting Thermostat controls the heating system by presetting program Use the tables to plan your program time periods and the temperatures you want during each ...

Страница 7: ...2 00 16 5 Table Three 5 1 1 4 Zones program could revised according to your request Heating Mode Morning Get up Our for work Came back Sleep Monday Values 6 00 21 8 00 16 5 18 00 21 22 00 16 5 Tuesday Values 6 00 21 8 00 16 5 18 00 21 22 00 16 5 Wednesday Values 6 00 21 8 00 16 5 18 00 21 22 00 16 5 Thursday Values 6 00 21 8 00 16 5 18 00 21 22 00 16 5 Friday Values 6 00 21 8 00 16 5 18 00 21 22 0...

Страница 8: ... 00 16 5 18 00 21 22 00 16 5 could revised according to your request Heating Mode Morning Get up Our for work Lunch Noon shift Came back Sleep Saturday Values 6 00 21 8 00 16 5 12 00 21 14 00 16 5 18 00 21 22 00 16 5 could revised according to your request Heating Mode Morning Get up Our for work Lunch Noon shift Came back Sleep Sunday Values 6 00 21 8 00 16 5 12 00 21 14 00 16 5 18 00 21 22 00 16...

Страница 9: ...ng Get up Our for work Lunch Noon shift Came back Sleep Saturday Values 6 00 21 8 00 16 5 12 00 21 14 00 16 5 18 00 21 22 00 16 5 Sunday Values 6 00 21 8 00 16 5 12 00 21 14 00 16 5 18 00 21 22 00 16 5 1 Temporary hold mode In normal operation press or temporary hold is flashing indicates thermostat is in temporary hold mode Press or to change set temperature the thermostat will override the curre...

Страница 10: ...ator press and hold the power button until the indicator A long bright yellow release this time SAS2010DE in the code state 4 The thermostat SAS908XWHB 7 DF1 in standby mode long according to the thermostat R button more than 3 seconds Emission to code command 5 The success of the code receiving portion yellow flashing 01 blinks four times Otherwise the code is unsuccessful Return reflector of the...

Отзывы: