background image

Fig 2. View of SW1 micro-switch sections

2.3. APPLICATION

ADA-401WA  converter   can   be   used   in   all   kind   of   local   systems   based   on   MicroLAN   networks   such   as:   the   registration   of   the

temperature, the monitored access, steering the functioning of  air-conditionings of both the heating, the remote control and the

supervision, in alarm, fire systems and the like much moved away from monitoring center. A market of alarm systems is one of most

quickly developing at present markets, which MicroLAN is being used among others for linking in of sensors with the alarm head

office, where in place a few or of a dozen or so wires will only be enough 3. In such applying does MicroLAN prevent the possibility of

cheating through clenching or incising the line and at the same time provides with the alarm system easiness of the automatic

configuration and the reconfiguration of the alarm system during the work. Much also leading test procedures which disabled elements

of the system are helping to eliminate is simpler than in standard solutions.

2.4. MICROLAN – NETWORKS WITH 1-WIRE CHIPS

The creators of 1-WIRE chips of new generation foresee the possibility of building networking systems with their use. With the

standard system of data transmission addressing for 1-WIRE, the protocol used to exchange data is inherently network protocol. The

data transmission addressing lies in the fact that each 1-WIRE chip has a unique, 8-bytes code saved in the internal ROM memory.

The manufacturer guarantees that this code is unique and relevant only to that audio chip.

2.5. CONVERSION OF  1-WIRE TO RS-485 STANDARDS

Because of the fairly complex 1-WIRE protocol, ADA-401WA converter is equipped with a microprocessor, which make easy access to

1-WIRE from a serial RS-485 bus. Communication with device connected to 1-WIRE is sending/receiving the appropriate command

via RS485 interface. Additional description all commands and communication are described in technical documentation DS2480B

driver available on manufacturer web page 

http://www.maxim-ic.com/quick_view2.cfm/qv_pk/2923

 or 

CEL-MAR

.

Additional commands used by ADA-401WA are described in section ADDITIONAL COMMANDS.

2.6. ISOLATION

Converter ADA-401WA has 2-way, 1kV= or 3kV= galvanic isolation (depend on version, described in section VERSIONS).

Fig. 3. Isolation diagram

3. INSTALLATION

This chapter will show how to connect ADA-401WA to PC,  RS485/422 bus, 1-WIRE line and power supply and how to use it.

To reduce disturbance from environment, it is recommended to:

use multipair type shielded cables,  which shield can be connected to the earthing on one end of the cable,

use the suitable diameter cable for power supply on account of voltage drop,

use the powering cable with a suitable section because of the voltage drops,

use the interference eliminators for powering the converter,

lay signal cables at a distance of not less than 25 cm away from power cables,

not powering the converters form the power-circuit of devices generate large impulse disturbance like contactors, relays, inverters.

3.1. ASSEMBLING

ADA-401WA converter case is adapted to assembly on TS-35 (DIN35) rail. To install converter should mount device on the rail upper

part of the case then press bottom part to hearing characteristic „Click” sound.

3.2. CONNECTION TO PC

ADA-401WA can be connected to RS232 port or USB of PC by the use of additional converter eg. RS232 to RS485 (ADA-1040) or

USB to RS485 (ADA-I9140). The connection is made via RS485 bus or RS422 bus, as on the figure bellow. 

5

ADA-401WA

ON

1 2

SW1

POWER SUPPLY

10 - 30VDC

1-WIRE

RS485/RS422

2-WAY ISOLATION

Содержание ADA-401WA

Страница 1: ...User manual ADA 401WA Addressable RS 485 RS 422 to 1 WIRE Converter 1 ADA 401WA Copyright 2001 2018 CEL MAR sp j io_ada 401wa_v3 20_en ...

Страница 2: ... ISOLATION 5 3 INSTALLATION 5 3 1 ASSEMBLING 5 3 2 CONNECTION TO PC 5 3 3 CONNECTION TO RS485 422 BUS 6 3 3 1 LINE TERMINATION 7 3 4 CONNECTION TO 1 WIRE NETWORK 7 3 4 1 CONNECTION 1 WIRE SENSORS 7 3 4 2 LIMITATIONS OF 1 WIRE BUS 7 3 5 POWER SUPPLY 8 3 6 ACTIVATION 8 4 CONFIGURATION 8 4 1 OPERATION MODE 8 4 2 CONFIGURATION 8 4 3 DATA TRANSMISSION DIAGNOSTICS 9 4 4 FIRMWARE UPDATE 9 4 5 EMERGENCY F...

Страница 3: ...ly after disconnecting the power supply circuit voltage Do not carry out the assembly or disassembly of the device if it is enabled This may result to short circuit and damage the device The device can not be used for applications that determine human life and health eg Medical 1 3 CE LABEL The CE symbol on the device CEL MAR means compatibility with electromagnetic compatibility Electromagnetic C...

Страница 4: ...tions through the RS 232 interface or USB in the computer of the class equipped with the PC into the appropriate software CEL MAR Company gives the materials to creating software on the basis of ADA 401WA converters ADA 401WA is equipped with screw terminal for twisted connection of 1 WIRE and RS 485 bus as well as for connecting the power supply Over voltage protection on each RS 485 line was mad...

Страница 5: ...icroprocessor which make easy access to 1 WIRE from a serial RS 485 bus Communication with device connected to 1 WIRE is sending receiving the appropriate command via RS485 interface Additional description all commands and communication are described in technical documentation DS2480B driver available on manufacturer web page http www maxim ic com quick_view2 cfm qv_pk 2923 or CEL MAR Additional c...

Страница 6: ...A 401WA VDD 1 W GND GND USB USB connector Screw connector RS485 RS422 RS485 4W 9600Bd 8 N 1 USB connector ADA I9140 USB Rx Rx Tx A Tx B Tx A Tx B Rx Rx Screw connector 1 WIRE Screw connector RS485 RS422 ADA 401WA PC VDD 1 W GND GND USB USB connector RS485 RS422 connector RS485 4W 9600Bd 8 N 1 USB connector ADA I9140 USB Rx Rx Tx A Tx B Tx A Tx B Rx Rx 1 WIRE connector RS485 RS422 connector ADA 401...

Страница 7: ...r when building the bus remember that each sensor is a shortening of 0 5 meters and 100 meters of cable causes additional capacity load data line 5nF increasing signal distortion 1 WIRE bus length and number of sensors will be less and will depend on used cables topology connection quality implementation of connections interference from external electromagnetic fields RECOMMENDS application of twi...

Страница 8: ...witch to configuration mode as in table below SW1 1 SW1 2 ON OFF In the configuration mode the yellow LED located by SW1 micro switch will blink with frequency 1 Hz Start the ADAConfig Software fig Below and make the configuration of transmission parameters for RS485 422 interfaces and set his visible address from RS485 bus Can be set also some of parameters the internal interface of converter for...

Страница 9: ...o delete zeroing of counters in the memory of the converter press Delete transmission errors In case of parity errors or frame errors should be checked the ADA 401WA converter s configuration and correctness connection of RS485 and 1 WIRE bus to the converter ports After finishing the diagnostics the SW1 micro switch should be set to run modeby using SW1 switch yellow LED blink OFF as below SW1 1 ...

Страница 10: ...to the converter If the software was loaded correctly yellow LED will be blink again with frequency 1 Hz After that set micro switch SW1 to run mode as shown in the table below SW1 1 SW1 2 OFF OFF The yellow LED will be OFF 4 5 EMERGENCY FIRMWARE UPDATE In case of the unsuccessful update of the converter software try again according to description in point FIRMWARE UPDATE If the update is still in...

Страница 11: ... ADDRESS OF ADA 401WA CONVERTER address byte from the scope 1 255 FRAME OF DS2480B DRIVER 1 WIRE BUS bytes sequence contains DS2480B driver frame of 1 WIRE bus or additional orders for ADA 401WA This sequence can not be longer than 950 bytes ADA 401WA converter with fixed addressing constantly listens for frames on RS485 bus If received frame contains byte of address equal to converter address the...

Страница 12: ...for ds18b20 sensors Maximum number of connected device 32 up to 100 ds18b20 sensors Maximum baud rate up to 230 4 kbit sek standard 0 do 16 3 kbps overdrive 0 do 142 kbps Transmission line Twisted cable 2 pair UTP Nx2x0 5 24AWG shield inside large interferences STP Nx2x0 5 24AWG Twisted cable 1 pair or 2 pair UTP Nx2x0 5 24AWG shield inside large interferences STP Nx2x0 5 24AWG Transmission type E...

Страница 13: ...e 40 70 C Casing Dimensions 53mm x 90mm x 62 mm Material Noryl UL 94 V O Degree of casing protection IP40 Degree of terminal protection IP20 Weight 0 10 kg According to standard DIN EN50022 DIN EN43880 Location during work Free Mounting method On the rail compliant with DIN35 TS35 standard 13 ADA 401WA ...

Страница 14: ...14 ADA 401WA ...

Страница 15: ...15 ADA 401WA ...

Страница 16: ...ta transmission converters with interface RS232 RS485 RS422 USB Current Loop Fibre Optic Converters and Ethernet or Wi Fi Please contact us to tell how you like our products and how we can satisfy you present and future expectation CEL MAR sp j Zakład Informatyki i Elektroniki str Ściegiennego 219C 25 116 Kielce POLAND Tel 48 41 362 12 46 Tel fax 48 41 361 07 70 Web http www cel mar pl en Office o...

Отзывы: