ITEM

Model
Data Rate
Connectors
Cabling
INPUT/OUTPUT voltage
Power Consumption
Device Type
Ambient Operating Temp
Relative humidity
Environment
Mounting 
Dimensions 
Weight
Compliance

SPECIFICATION

Q34 – E1000
1000 Mbps full duplex
RJ45
Category 5e or better
42 -  57 VDC
7.5 watts typ.
Class II
0 – 40º C
0 – 95% Non-condensing
Indoors
Wall or shelf
140mm (L) x 66mm (W) x 28mm (H)
0.7kg
FCC Part 15, Class B
ICES 03
CE
IEEE 802.3at-2009
RoHS
UL/CSA/EN 62368-1

Technical Specifications: 

Cel-Fi Quatra Range Extender 

QUATRA ACCESSORY

STEP 2: 

Connect INPUT and OUTPUT cabling

•  Extender power is provided by the cable from the QUATRA 

NETWORK UNIT.

•   RJ45 LED #1 (solid amber) indicates power.
•   RJ45 LED #2 will blink green during initialization, and will be solid 

green when the Extender has passed self-test and is operating 
normally.  

•   If both LEDs blink off periodically on a port, the port is resetting to 

try and establish communications with the QUATRA NETWORK 
UNIT  or  COVERAGE UNIT it is connected to. Check cables and 
connections if this occurs.

•  If both INPUT LEDs are off, check the cable to the QUATRA 

NETWORK UNIT and that the NETWORK UNIT is powered up.

•  If both OUTPUT LEDs are off, check the cable to the QUATRA 

COVERAGE UNIT.

•   For further assistance, please consult your installer or contact  

 

http://www.cel-fi.com/support

.

General Information

Safety Precautions

•  Use this product indoors. It should not be used outdoors.
•  This products is designed to be powered over Ethernet cabling.
• When installing the equipment, all the requirements of the 

manufacturer and the referenced standards must be met.

•  There are no user serviceable parts inside.
•  CAUTION: Changes or modifications to this product not expressly 

approved by Nextivity may void your right to operate the equipment.

Warranty

Nextivity Inc. provides a limited warranty for its products. For details, 
please refer to 

www.cel-fi.com/warranty

.

Limitation of Liability

In no event shall Nextivity, nor its directors, employees, agents, 
suppliers or End Users, be liable under contract, tort, strict liability, 
negligence or any other legal or equitable theory with respect to the 
Products or any other subject matter of this Agreement (i) for any lost 
profits, cost of procurement of substitute goods or services, or 
special, indirect, incidental, punitive, or consequential damages of any 
kind whatsoever or (ii) for any direct damages in excess of (in the 
aggregate) the fees actually received by Nextivity from End User with 
respect to the Products actually purchased and paid for.

See 

www.cel-fi.com

 for list of patents covering this product.

Electromagnetic Compatibility (EMC)

This equipment has been designed and tested to fulfill applicable 
standards for:

• Radio frequency emission when installed according to the 

instructions and used in its intended environment.

• Immunity to electrical and electromagnetic phenomena when 

installed according to the instructions and used in its intended 
environment.

USA

 

This equipment generates, uses and can radiate radio frequency energy 
and, if not installed and used in accordance with the instructions, may 
cause harmful interference to radio communications. However, there is 
no guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, 
the user is encouraged to try to correct the interference by one or more 
of the following measures:

•   Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver.
•  Connect the equipment into an outlet on a circuit different from 

that to which the receiver is connected.

•  Consult the dealer or an experienced radio/TV/IT technician for help.

Europe

 

Canada

 

This Class B digital apparatus complies with Canadian ICES-003.

Compliance Contact

In the event of a regulatory compliance issue, please contact Nextivity 
Inc. at 

www.nextivityinc.com

.

Note: Certifications are regional; not all products need or have the 
same certifications. Please check the specific model number to 
determine exactly which certifications it has.

Patents

This product is covered by Nextivity, Inc., US patents and patents 
pending. Please refer to 

www.cel-fi.com

 for details.

Support

Should you require any assistance, please contact your QUATRA 
reseller. If your questions cannot be answered immediately, your 
reseller will forward your queries through the appropriate channels to 
ensure a rapid response. If you still need assistance visit: 

 

http://www.cel-fi.com/support

.

Installation

STEP 1: 

Locate and mount the Extender unit

•  Input and Output port LEDs should be clearly visible.
•  Allow adequate ventilation.
•  Do not mount in direct sunlight, near heat sources, or in weather 

exposed areas.

•  The Cat 5e cable (or better) that connects the INPUT port to the 

QUATRA NETWORK UNIT should not exceed 100 meters in length.

•  The Cat 5e cable that connects the OUTPUT port to the QUATRA 

COVERAGE UNIT should not exceed 100 meters in length. 

QUATRA Range Extender cables to QUATRA NETWORK AND 

COVERAGE UNITS must be dedicated (proprietary data link)!  The 

system will not function if common shared LAN resources are used 

with cabling (routers, switches etc). 

QUATRA Range Extender heat sink edges may be sharp. 