below:
Id
:
0010
;
AGC is ready; Ford:100.0w; REF:001.0w; ATT:100; AGC:100; Temp:40C;
DC:38V; PA:ON ; FAN:ON ;AFWD:1V; last alarm
:
the alarm information is as
follows:
0: "no alarm" Normal
1: "P-A RF in large" Preamplifier signal input is too large.
2: "P-A RF in small" Preamplifier input is too small.
3: "P-A status off" Preamplifier closed.
4: "Temp high" Temperature is too high.
5: "FORD Pow alarm” Transmitting power is too high.
6: "REF Pow large" Reflection power is too high.
7: "MAIN DC alarm" Abnormal voltage alarm
1
、
ID
:
0010 Equipment No. Refer to 4-1 ID
2 AGC is ready AGC status NOT READY or READY
3
、
FORD
:
100.0W Current transmission power Unit: W.
4
、
REF
:
001.0W Current reflection power Unit: W.
5
、
ATT
:
100 Current AGC value, refer to AGC value in 4-1
6.
、
AGC:100 Manually set-up AGC power
,
refer to AGC value in 4-1.
7
、
TEMP
:
40C Current machine temperature Unit: °C
8
、
DC
:
38V Current power supply voltage 27V for 1W
,
39V for machine
over 1W.
9
、
PA
:
ON Current amplifier operation status ON or OFF
10
、
FAN
:
ON Current fan open status ON or OFF
11
、
AFWD
:
1V Circuit voltage of amplifier power detection should be the