FAULTS

CAUSES

 

SOLUTIONS

Pump does not 

run

Interruption of the power supply, 

short circuit or an insulation fault in 

the motor coil

Check power supply

Call an expert to check the pump unit

Pump runs, 

but little or no 

delivery

Pump or pipes are blocked due to 

foreign matters

Lack of supply water

Primed incorrectly

Air in suction pipes

Check all filters/check valve for foreign matters 

Ensure all taps are turned on
Repeat priming procedure (refer to page 8 for flooded suction or 

page 9 for lift suction) to remove any air from the system

Check the tightness of the whole pipe up until the pump and 

tighten it

Motor overheats

Low voltage

Ambient temperature above +40 °C 

or insufficient ventilation

Ensure power supply is not running on an extended cable 

exceeding 10m. Check voltage on terminals of the motor. It should 

be within ± 10 % of 230V (this should be carried out only by 

qualified personnel)

Relocate pump to a cooler, better ventilated environment

The flow is too 

little

Length of pipe is excessive and 

diameter is too small 

Excessive head

Decrease pipe length and increase pipe size (diameter)

Decrease head on pump

Pump vibrates

Fuse blows or 

circuit breaker 

trips when pump 

starts

Controller failure 

light

Incorrectly mounted/fixed

Pump jammed. 

Motor stator may be defective, 

circuit leakage or insulation failure. 

Fuse size or circuit breaker may be 

too small

Loss of prime or no water in tank

Electronic controller faulty, maybe 

damaged by power surge or spike

Ensure pump is fastened to a solid surface by two mounting 

screws

Get pump serviced

Check pump is primed and water supply is sufficient

Replace controller

  FAULTS, CAUSES AND SOLUTIONS

Содержание ECOJET 1000PC

Страница 1: ...tion but due to continuous development and improvement the right is reserved to supply products which may differ slightly from those illustrated and described in this publication 1 ELECTRIC MOTORS AND...

Страница 2: ...FOR LIFT SUCTION 9 MAINTENANCE ELECTRONIC PRESSCONTROL 0 C 40 C 14 OPTIONAL EXTRAS 11 2 YEAR WARRANTY INTEGRATED INTELLIGENCE INTEGRATED INTELLIGENCE DIMENSIONAL DRAWING 5 6 6 6 INSTALLATION 6 ELECTRI...

Страница 3: ...mm non return valve 5m x 12mm thread seal tape 1 5 metre lead with NZ AU compatible plug Installation and operating instructions Certified for conformity to AS NZ standards Warranty card Dear Customer...

Страница 4: ...r design of the ECOJET Premium Efficiency Series was developed by focusing on the mechanisms causing water hydraulic loss The ECOJET was created for the Australian and New Zealand market using the lat...

Страница 5: ...ly searching for improved ways to operate All ECOJET packaging material can be recycled so we encourage you to do so responsibly Old pumps contain material that can be recycled please arrange for the...

Страница 6: ...cal data Table 1 0 The limits stated there must not be exceeded under any circumstances ALTERATIONS AND SPARE PART PROCUREMENT Any alterations to the pump are only permitted in agreement with the manu...

Страница 7: ...mm is required the discharge pipe must be installed with a vertical rise of at least 300mm Frost damage will not be covered under warranty lt is the operator s responsibility to take all preventative...

Страница 8: ...ks are present please tend to appropriately If no leaks are present plug in pump to begin use of your ECOJET Leaks of any size large or small will cause the pump to cycle and not function correctly an...

Страница 9: ...Plug pump into main socket Run the highest and furthest valve tap from the pump for 2 minutes e g shower or garden tap on opposite side of house Close the discharge valve once excess air has evacuated...

Страница 10: ...hen it is necessary to completely drain the pump using the drain plug at the bottom of the pump housing For prolonged stand down periods e g winter shutdown the pump needs thorough cleaning complete d...

Страница 11: ...irection suddenly Water hammer commonly occurs when a valve closes suddenly at an end of a pipeline system and a pressure wave propagates in the pipe This pressure wave can cause major problems from n...

Страница 12: ...s screws and spanner 10 Twin Filter Housing Unit also includes stainless steel faucet hoses and tap 10 TWIN FILTER HOUSING KIT 10 JUMBO FILTER HOUSING KIT 25mm 1 Brass Inserts 2x 10 FILTER HOUSING KIT...

Страница 13: ...s more holding capacity than traditional rope wound elements Suitable for repeated re use by simply washing in warm soapy water High flow rates improving water pressure and flow Pre treatmentforpolysp...

Страница 14: ...ditional pressure controller and pressure tank protecting the pump in the case of water shortages PRESSCONTROL Starts and stops the pump in accordance with the opening and closing of the taps Maintain...

Страница 15: ...est tap does not exceed 15m It is advisable to connect the unit outlet to the system by means of a flexible hose Safety valve preventing water emission in case of diaphragm breaks DO NOT TOUCH It is i...

Страница 16: ...Name 26 Serrated lock washer external teeth 4 27 Washer 4 28 Hexagonal nut M4 29 Cross recessed pan head tapping screws ST3 5x12 30 Capacitor 10uF 450V 31 Capacitor Gland 32 Wiring diagram 33 Upper pa...

Страница 17: ...l ring 22 Front cover 23 Rubber Gesket 24 Bearing 6202 2RS 25 Rotor assembly 26 Stator assembly 27 Motor Base 28 Terminal box pad No Name 29 Bottom part of terminal box 30 Cross recessed pan head scre...

Страница 18: ...ring d15 20 Front cover 21 Rubber Gesket 22 Bearing 6202 2RS 23 Rotor assembly 24 Bearing AC6202 2RS 25 Stator assembly 26 Motor Base 27 Terminal box pad No Name 28 Bottom part of terminal box 29 Cros...

Страница 19: ...the pump and tighten it Motor overheats Low voltage Ambient temperature above 40 C or insufficient ventilation Ensure power supply is not running on an extended cable exceeding 10m Check voltage on te...

Страница 20: ...t 2 711 Boundary Road Coopers Plains 4108 Queensland Australia PRODUCT TYPE This product has been tested to relevant standard and found compliant with specification CEG AS NZ Issue F0054 version A Thi...

Отзывы: