PC CONFIGURATION

Disable also the screensaver, if any. To do this, right 

click with the mouse on any free area of the desktop 

(with no icons or windows), and select “Personalize” 

from the context menu.

 

Press on the “Screen Saver” icon in the bottom right 

corner, and select “None” in the next dialog box.

3.4  DISABLING WINDOWS FIREWALL 

 From the Control Panel  select “Administrative Tools” 

and double click on “Services”:

Содержание NewTom GO 2D

Страница 1: ...Cod 97071219 Rev 01 01 2017 NewTom GO 2D 3D technical manual EN...

Страница 2: ......

Страница 3: ...SERVER SOFTWARE INSTALLATION 19 3 9 INTEL PRO 1000 DRIVER UPDATE 21 3 10 ACQUISITION SERVER CONFIGURATION 23 3 11 NNT SOFTWARE INSTALLATION AND CONFIGURATION 27 4 CALIBRATION See corresponding 3D CALI...

Страница 4: ...2 EN NewTom GO 2D 3D TECHNICAL MANUAL CONTENTS...

Страница 5: ...following 1 If the device is in AIR version check that the screws fastening the column to the wall are not too tightened and the feet are adjusted so that the column is levelled and is not affected by...

Страница 6: ...LED only if using button 96609090 white wire 4 Emission LED only if using button 96609090 blue wire K14 External warning lights clean contacts no voltage provided Optional Use lamps up to 240 VAC max...

Страница 7: ...OVAL 2 COVER HANDLES MIRROR REMOVAL 2 1 MONOBLOC COVER Remove the highlighted screws and pull the interlo cking cover 2 2 PANEL COVER Remove the highlighted screws and pull the interlo cking rear cove...

Страница 8: ...OVER HANDLES MIRROR REMOVAL 2 3 MIRROR Slightly press the mirror against the column move the mirror upwards and turn it outwards to remove it 2 4 HANDLES Remove the accessory drawer and loosen the hi...

Страница 9: ...ighlighted screws and remove the cover 2 6 SIDE COVERS Loosen the highlighted screws and remove the interlo cking side covers 2 7 ARCH COVER NOTE Before removing the arch cover it is necessary to remo...

Страница 10: ...with the specifications and install the entire software autonomously The 2 PC network cards will be needed for the communication between device and PC and for the connection between Sensor and PC The...

Страница 11: ...TECHNICAL MANUAL EN PC CONFIGURATION 3 3 OPERATING SYSTEM SETTINGS Open the Control Panel select User Account and then Change User Account Control Settings Select the lowest notification level Never N...

Страница 12: ...NFIGURATION From the Control Panel select Power Options On the Balanced profile select Change plan settings Set Turn OFF display and Put the computer to sleep to Never Select Change advanced power set...

Страница 13: ...h the mouse on any free area of the desktop with no icons or windows and select Personalize from the context menu Press on the Screen Saver icon in the bottom right corner and select None in the next...

Страница 14: ...cal area network or directly to the Acquisition Server PC In both cases the 3D panel Ethernet connection must absolutely be point to point and is always managed autonomously by the software and the ma...

Страница 15: ...d and press enter The connection management window will open If a fixed IP address must be set for the network card dedicated to communication right click on the corresponding connection not the INTEL...

Страница 16: ...between 1 and 254 except for the device ip address 160 in case of default address The Subnet mask is already filled out properly Click OK to confirm On the other hand in case of connection to a local...

Страница 17: ...ach panel is equipped with a specific installation CD containing data that are not interchangeable with other units Carefully keep the CD and make sure that at least one backup copy is available Inser...

Страница 18: ...ra Driver are already present and will uninstall them if necessary WARNING this procedure may take a long time do not interrupt the process At the end the PC will restart and resume installation If th...

Страница 19: ...xe file the screen with the list of network cards available in the PC will appear Only near Intel Pro 1000 board connected to the 3D panel it is necessary that in Current Driver column the eBUS Univer...

Страница 20: ...k on Computer select Properties and select Device Manager in the left column Expand the Network adapters branch and right click on Intel PRO 1000 GT Desktop Adapters select Properties Select Advanced...

Страница 21: ...t displayed directly in this window If it is not displayed search for the Performance Options item and click on Properties The Receive Buffers value is displayed there 3 8 ACQUISITION SERVER SOFTWARE...

Страница 22: ...20 EN NewTom GO 2D 3D TECHNICAL MANUAL EN PC CONFIGURATION Select I accept the agreement then click Next Select the installation for 2D and 3D devices and click on Next Click on Install...

Страница 23: ...000 DRIVER UPDATE The Intel PRO 1000 ethernet card is automatically recognized from the Operating System However the default system driver should be updated to a specific version in order to ensure th...

Страница 24: ...22 EN NewTom GO 2D 3D TECHNICAL MANUAL EN PC CONFIGURATION Choose I accept and click Next Press Next and proceed with the default options Click on Install...

Страница 25: ...t Click on Finish Reboot the PC 3 10 ACQUISITION SERVER CONFIGURATION Once the PC IP addresses have been properly set the Acquisition Server can be configured Clicking on the Acquisition Server icon i...

Страница 26: ...concerning machine errors the second one bigger Clicking on the Settings icon at top right the connection and software option panel will open Select Change Mode and confirm the application restart mes...

Страница 27: ...URATION Go back to Settings select Find Device The device will be searched automatically select it and confirm Select Connect Device and tick off the Auto Connect Device option Click on Close After a...

Страница 28: ...C CONFIGURATION Now set the connection with the 3D panel Click again on Settings and on Find Sensor The device 3D panel will be searched automatically Select it and confirm Confirm by Close The acquis...

Страница 29: ...o receive images from the 3D device is NNT version 6 5 or higher installed in its MAIN WORKSTATION version NNT must be installed on the Acquisition Server PC Start NNT installation select 3D device in...

Страница 30: ...GO 2D 3D TECHNICAL MANUAL EN PC CONFIGURATION Wait and click on Install At the end restart the computer Upon first NNT launch the display mode has to be selected Oral and Maxillofacial Surgery is the...

Страница 31: ...mode by pressing CTRL ALT SHIFT END simultaneously the Service Level message under NNT in the main screen confirms proper execution Press ALT F10 and enter the 336699 password Click on Browse in the w...

Страница 32: ...ce Mode press ALT F10 and enter the 12345 password The window displayed in the figure will open Click on Find Select the device and click on Add selected Make sure that the settings are correct as dis...

Страница 33: ...C CONFIGURATION After saving the settings the following NNT display will appear Click on the button in the top right corner and select the virtual keyboard from the menu Upon first launch the virtual...

Страница 34: ...erver software and select Clients Allowed The list of all the clients that have attempted to connect to the virtual keyboard will be displayed Tick off the necessary one s and close Now restarting the...

Страница 35: ...33 EN NewTom GO 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION 5 CONTROL BOARDS DESCRIPTION 5 1 UNIT BLOCK DIAGRAM...

Страница 36: ...NG The K17 input terminal board is always powered live as marked on the info plate below Before handling always cut the power via the external circuit breaker Once the power to the device has been cut...

Страница 37: ...35 EN NewTom GO 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION...

Страница 38: ...v 6 3x32 230V F2 Standby power fuse FUSE 2AT 230V F1 48V output fuse FUSE 2 5AF 450V DC DIP Switches SW1 Always off reserved use 5 2 3 LEDS LIST LED ID COLOR NAME ON BOARD DESCRIPTION DL1 YELLOW ACT C...

Страница 39: ...RDYL External ready lamp relay status Normally off on when unit is ready DL24 YELLOW XRYL External x ray on lamp relay status Normally off on during x ray emission DL25 GREEN BUT Xray button pressed...

Страница 40: ...38 EN NewTom GO 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION PIN 4 signal X ray ON...

Страница 41: ...39 EN NewTom GO 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION...

Страница 42: ...witches DESCRIPTION SW4 Not used all OFF SW2 Reboot button SW3 Factory reset switch 5 3 3 LEDS LIST LED ID COLOR NAME ON BOARD DESCRIPTION DL1 YELLOW CAN ACT CAN activity Normally on flashing On stead...

Страница 43: ...3 GREEN 24V 24V tension present normally on DL24 GREEN 5 0V 5V CPU tension present normally on DL25 GREEN 1 2V 1 2V CPU tension present normally on DL32 GREEN 48V R axis Motor tension present normally...

Страница 44: ...42 EN NewTom GO 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION 5 4 SENSOR INTERFACE BOARD 97661485...

Страница 45: ...43 EN NewTom GO 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION...

Страница 46: ...5 4 1 CONNECTORS LIST CONNECTOR DESCRIPTION K1 Sensor synchronisation supply from LOGIC K2 24V DC Panel supply K3 Sensor synchronisation 5 4 2 LEDS LIST LED ID DESCRIPTION DL1 VIN 48V from LOGIC boar...

Страница 47: ...45 EN NewTom GO 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION 5 5 MONOBLOC AREA...

Страница 48: ...EN CONTROL BOARDS DESCRIPTION 5 6 KEYBOARD BOARD 97661484 5 6 1 CONNECTORS LIST CONNECTOR DESCRIPTION K1 Keyboard signals from LOGIC 5 7 LOGO BOARD 97661539 5 7 1 CONNECTORS LIST CONNECTOR DESCRIPTIO...

Страница 49: ...e centred with respect to the sagittal laser perform a mechanical adjustment Proceed as follows 1 Check that craniostat is centred 2 Close the 2 side tabs 3 Remove lower cover There are no screws just...

Страница 50: ...l out and distribute the Report of assembly using the Form FDA 2579 upon completion of an installation and within 15 days of the date of installation For more guidance please refer to FDA document num...

Страница 51: ......

Страница 52: ......

Отзывы: