10

EXPLOSIVE FORCE

P9 : lvl 1

P10 : lvl 2

Increases the capacity for instantaneous maximum force.

P11 : lvl 3

ENDURANCE

P12 : lvl 1

P13 : lvl 2

Improves the capacity for enduring a high workload over a pro-
longed period of time.

P14 : lvl 3

RESISTANCE FORCE

P15 : lvl 1

P16 : lvl 2 

Improves the capacity to develop a high level of force over a pro-
longed period of time.

P17 : lv 3

CAPILLARISATION

P18 : lvl 1

P19 : lvl 2 

Increases blood flow to the muscle.

RECOVERY

P20

Improves circulation and elimination of lactic acid after a work-
out.

Note:

 The TENS program does not always treat the cause of the pain. 

If the pain persists, seek medical advice.

ACTIVE RECOVERY

P21

Increases the ability to regain muscular capacity after a workout.

MASSAGE

P22

The comfortable vibrations increase circulation and help the mus-
cles to relax.

DRAINAGE

P23

The  comfortable  vibrations  increase  circulation  and  promote 
elimination of toxins.

TENS CONVENTIONAL

P24

Offer  effective  pain  relief.  It  can  be  used  at  anytime  to  soothe 
pain.

TENS ENDORPhIN

P25

Offer effective pain relief.

2526_CEFAR_MYO.ACTIV_X2__ENG_3-110   10

2006-07-07   11:09:58

Содержание activ X2

Страница 1: ...i 27 Manual de instrucciones 39 Istruzioni per l uso 51 Manual de instru es 63 Gebruikershandleiding 75 87 Instrukcja obs ugi 99 111 Haszn lati tmutat 123 bruksanvisning 135 istimal sureti 147 bruksan...

Страница 2: ...ual Amplitude Setting 8 Program Guide 9 CEFAR EASY TRAINING Sets and Repetitions Reps 9 Active Rest 9 Levels 9 Program Description 9 CEFAR MYO X2 9 CEFAR ACTIV X2 11 Key Lock 12 Pausing the Program 12...

Страница 3: ...regnant The reason is that theoretically the current could affect the foetus s heart although there are no reports of it being harmful If skin irritation should occur treatment should be temporarily d...

Страница 4: ...cted amplitude level in AUTO test mode 3 AUTO P AUTO S Decreases or increases the stimulation amplitude intensity of the stimulation for each channel Note Always increase the amplitude cautiously AUTO...

Страница 5: ...Number Intensity level See Program Description for further information 8 remaining Time Remaining program time in minutes and seconds Time is flashing during timer setting also counts down the time f...

Страница 6: ...2 Attach the electrodes to your body Follow the recommendation in Electrode Placement Guide at the end of this user manual 3 Connect the cable to one of the stimulator s two channels 4 Press AUTO P A...

Страница 7: ...o increase or decrease stimulation amplitude at any time until the stimulation feels pleasant presumed that the key lock is inactivated If doing so the Automatic Amplitude Setting is lost and the stim...

Страница 8: ...decrease muscle soreness afterwards Note Do not forget to set the amplitude for the Active Rest in manual mode In auto mode the amplitude adjusts automatically in Active Rest Levels Some of the progra...

Страница 9: ...Improves circulation and elimination of lactic acid after a work out Note The TENS program does not always treat the cause of the pain If the pain persists seek medical advice Active Recovery P21 Inc...

Страница 10: ...aximal training ses sions P13 lvl 3 Warm Up P1 Prepares the muscle for exercise Recovery P14 Improves circulation and elimination of lactic acid after a work out Drainage P15 The comfortable vibration...

Страница 11: ...e AA 1 5V Make sure the polarisation placement and is correct 4 Replace the battery cover 5 Dispose of the exhausted batteries according to local regulations Care Instructions Taking care of and clean...

Страница 12: ...nce this can damage the stimulator Technical Data CEFAR MYO X2 and CEFAR ACTIV X2 are electrical stimulators with two chan nels intended for muscle training and pain relief They can deliver 100 mA of...

Страница 13: ...chargeable or 2 x 1 2 V AA rechargeable batteries Current consumption for one channel 80 Hz 30 mA 150 mA I r m s max channel 11 mA Size 120 x 50 x 30 mm Weight ca 180 g Key to the Stimulator Symbols R...

Страница 14: ...195 2526_CEFAR_MYO ACTIV_X2_EP_195 2195 195 2006 07 07 11 49 39...

Страница 15: ...196 2526_CEFAR_MYO ACTIV_X2_EP_195 2196 196 2006 07 07 11 49 40...

Страница 16: ...197 2526_CEFAR_MYO ACTIV_X2_EP_195 2197 197 2006 07 07 11 49 41...

Страница 17: ...198 2526_CEFAR_MYO ACTIV_X2_EP_195 2198 198 2006 07 07 11 49 42...

Отзывы: