3.0 

PROGRAMMING 

 

NOTE: 

It is recommended that you ground yourself to prevent ESD 
damage to the PCB(s). 

 

*****WARNING*****

 

 
 

A.  

Never install telephone wiring during a lightning storm. 

 
 

B.  

Never install telephone jacks in wet locations unless the jack is   

 

 

specifically designed for wet locations. 

 

 

C.  

Never touch uninsulated telephone wires or terminals unless the

  

 

 

telephone line has been disconnected at the network interface. 

 

D.

 

Use caution when installing or modifying telephone lines. 

 
 

1)

 

Connect

 

the Ceeco XFD Series Telephone

 to the Telephone Line provided by your local 

            Telephone Company or to analog type PABX Station. 
 

2)

 

Using another Telephone (Different Telephone Line or cell phone) equipped with a Touch Tone 
Keypad, 

call the CEECO XFD Series Telephone

 

3)

 

After 4 rings

 of the CEECO Telephone, 

answer it

 by lifting the handset off hook and keep it that 

way.  Three tones should be heard indicating the phone is ready for remote input. 

 

4)

 

With the other phone, enter # 2 3 3 2 6 *

.  This is the factory default 5-digit pass code.  

Instructions for changing the pass code appear below.  

Two (2) beeps

 will be heard indicating a 

valid Pass Code entry.  Five (5) beeps will only be heard when an error occurs and programming 
was not accepted.  

Two (2)  beeps

 will always be given to indicate each successful programming 

entry below. 

 

 

Enter # 9 7 * to clear all memory.  It is not necessary to do this hereafter.  Individual 
programming options may be changed from time to time by entering only the necessary key 
presses and there is no requirement to “re-program” everything each time.   

 

 

 

 

 

If it is necessary to enter a PBX or other access digit, enter # 5 5 x * (where x = any number 0 
thru 9 ).  When a call is initiated, the phone will automatically dial this digit first. 

 

 

If it is ever necessary to Disable the PBX/Access feature enter # 5 5 *. 

 

 

 

If a pause is required between the PBX or Access number dialing and the auto-dial number,  

 

enter # 5 8 x * (where x = # of seconds for the pause.  1 to 9 seconds maximum).   

 

 

If it is required that the phone dial in Rotary Dial Mode enter # 5 7 1 * (Rotary 10pps). 

Содержание SSW-321-Dr1

Страница 1: ...DEL SSW 321 Dr1 MINI WALL TELEPHONE EQUIPPED WITH XFD PRINTED CIRCUIT BOARD Serving the Telephone Industry Since 1930 Communication Equipment 519 W est South Park Street Engineering Company Okeechobee...

Страница 2: ...O for assistance MODEL NUMBER MODEL SSW 321 Dr1 STAINLESS STEEL MINI WALL TELEPHONE WITH XFD PRINTED CIRCUIT BOARD SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please...

Страница 3: ...3 TABLE OF CONTENTS SECTION PAGE 1 0 INTRODUCTION 4 2 0 GENERAL DESCRIPTION 4 3 0 PROGRAMMING 5 4 0 OPERATION 6 5 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 7 6 0 TESTING 7 7 0 SPECIFICATIONS 8 8...

Страница 4: ...that will dial a single number of up to eleven 11 digits The auto dialing feature is activated by hookswitch closure when the handset is lifted The board is also equipped to dial a PBX or other access...

Страница 5: ...dicating the phone is ready for remote input 4 With the other phone enter 2 3 3 2 6 This is the factory default 5 digit pass code Instructions for changing the pass code appear below Two 2 beeps will...

Страница 6: ...To program the Auto Dial Number enter 1 9 x where x the number to be dialed In order to change the Pass Code enter 3 1 x where x any 5 Digit pass code When programming is completed simply hang up Rele...

Страница 7: ...terminate on to the RJ11C terminal block on the backplate 5 6 The use of a gas tube station protector is recommended The station ground should not exceed 50 ohms 5 7 Plug the modular line cord from th...

Страница 8: ...00 ohms HEARING AID COMPATIBLE Meets EIA standards ENVIRONMENTAL Temperature 0oC to 50oC Humidity 20 90 non condensating ENCLOSURE Brushed 16 ga Stainless Steel DIMENSIONS 5 Wide x 10 3 4 High x 2 dee...

Страница 9: ...Handset with Armored Cord 1 401 009 Ringer 1 301 592 Receiver Operated Magnetic Hookswitch 1 301 018 Modular Cord 1 321 015 Stainless Steel Backplate 1 321 016 1 4 20 x 3 4 Security Screw 1 301 005 Ca...

Страница 10: ...one Network through a registered jack provided by the telephone company in your area This jack is a modular outlet which you can order from your local telephone company 9 3 NOTIFICATION TO THE TELEPHO...

Страница 11: ...to the defective unit This information must be inside the shipping container 10 2 DIRECT ALL INQUIRES TO CEECO Repair Department 519 West South Park Street Okeechobee Florida 34972 863 357 0798 10 3 N...

Страница 12: ...nd which have been caused by neglect abuse acts of God or improper operation of equipment CEECO will repair or replace any unit during this period if found to be defective for reasons other than abuse...

Отзывы: