![CEECO SSP-571-D2 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/ceeco/ssp-571-d2/ssp-571-d2_service-manual_2578875005.webp)
ISSUE 4.0
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
5
3.0 PROGRAMMING
NOTE:
It is recommended that you ground yourself to prevent ESD
Damage
to
the
PCB(s).
3.1
Connect the telephone
to a working telephone line or a DTMF test set
before programming.
3.2
Locate the multicolor ribbon cable, extending from the Printed Circuit
Board, with a white connector hanging loosely. Locate the programming
keypad (provided separately), which has the mating end of the white
connector attached to it.
Connect the keypad
to the ribbon cable, by way
of the two connectors.
3.3
Move
the
mini-jumpers
(located on the Printed Circuit Board) to the
"ON"
position, as depicted on the last page of this manual.
3.4
Press the CALL button
and wait for dial tone before programming any
digits.
3.5
It is important to be slow and deliberate when pressing the keys of the
programming keypad. A missed or partial tone could result in improper
programming.
NOTE
: Once the “#" (pound) key has been entered you may get an
operator recording or a fast busy, please disregard and continue
programming.
3.6
Press the CALL button
located on the front of the phone and
utilize the
programming keypad to enter:
#97 #18# #19#
This will clear all user programmable memory, in order to begin.
3.7
Enter # 0 0 followed by a series of ten (10) Digits
as selected from the
options on the following page. By entering 0 thru 9 into each of the 10
digits, the phone is customized for the particular installation. A selection
for all ten Digits must be entered in order for the phone to operate
properly.