CEECO SSP-570-D Скачать руководство пользователя страница 6

ISSUE 4.0 

CEECO 

Communication Equipment & Engineering Company 

PROPRIETARY 

6

 

3.6

 

If

 the number to be programmed is a (1+) or 

long-distance

 call, locate the 

plastic 

mini-jumper

 at the 

“J1”

 position location of the ATD-11 printed 

circuit board.  The ATD-11 circuit board has a smaller board mounted to 
it, which has several rows and columns of copper contacts/pins on it.  The 
“J1” position you are looking for is located just below the bottom right 
hand corner of that smaller piggyback board.  The “J1” position has three 
copper contacts/pins, with a plastic mini-jumper, and is readily identified 
by the “+1” that appears on the board in small white print just to its left.  
By moving the plastic mini-jumper so that it bridges the middle copper pin 
and the 

far left

 or “+1” pin, you will cause the digit “1” to automatically 

dial out prior to any other programmed number.  If your desired number is 
local or does not need a preceding one, then move the mini-jumper to 
bridge the middle copper pin and the far right pin.  You will observe a “P” 
in small white print on the circuit board just right of this right hand pin

(Please refer to diagram 3.12, on page 8).   

 

3.7

 

Next, locate the plastic 

mini-jumper

 at the 

“J3”

 position of the circuit 

board, which is just below the “J1” position. It could also be considered 
the second plastic mini-jumper below the bottom right hand corner of the 
small piggyback board. Just left of this “J3” position, in small white print, 
appears “11”, bridging the middle and 

far left

 corner pins. The “J3” mini-

jumper should always be in this position, regardless of the number you are 
programming. 

(Refer to diagram 3.12 on page 8).

 

 

3.10

 

Now let’s program the 

number to be automatically dialed

.  Looking at 

the piggyback circuit board containing several rows and columns of 
copper pins, you will see 

ten plastic mini-jumpers

.  The rows are labeled 

1 thru 0 on the left side of the circuit board.  The columns are labeled A 
thru K across the top of the circuit board and the columns of copper pins 
are in pairs.  Each pair of copper pins represents a number to be dialed.  
For example, let’s assume that you want to program the phone to dial 1-
954-587-5430.  Place the plastic mini-jumper under column “A” across 
the two copper pins that align with row “9”.  Place the mini-jumper under 
column “B” so that it bridges the pair of copper pins in row “5”.  Place the 
mini-jumper under column “C” across the pair of copper pins in row “4” 
and so on, until the entire number is programmed.  Each column 
represents a digit, so do not skip any.  This example happens to include a 
long distance number, so you would move the “J1” jumper to the “+1” 
position.  If your desired number were short, like 911 for example, the 
programming would be slightly different.  In a case such as that, you 
would place the jumper under column “A” in the “9” position and the 
jumpers under columns “B” and “C” in the “1” position.  You would then 
remove the seven remaining black plastic mini-jumpers, with the 
exception of positions J1, J2 & J3, so that no erroneous digits dial out.  

Содержание SSP-570-D

Страница 1: ...FOR MODEL SSP 570 D HANDS FREE ELEVATOR PHONE EQUIPPED WITH LOW POWER SPEAKER BOARD Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street Engineering Company Okeech...

Страница 2: ...ce MODEL NUMBER MODEL SSP 570 D EQUIPPED WITH LOW POWER SPEAKER BOARD AND ATD 11 TONE DIALER SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information...

Страница 3: ...N PAGE 1 0 INTRODUCTION 4 2 0 GENERAL 4 3 0 PROGRAMMING 5 4 0 TESTING OPERATION 10 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 11 6 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 11 7 0 SPECIFICATIONS 13...

Страница 4: ...y vandal resistant Stainless Steel Panel Speakerphone Instead of a hookswitch and handset the SSP 570 D has a Press to start Press to stop button for the initiation and termination of phone calls This...

Страница 5: ...copper pins This is the ON position which activates the Time Out Disconnect feature When the automatic call disconnect feature is not desired the jumper should be in the OFF position jumper bridges th...

Страница 6: ...J3 position in small white print appears 11 bridging the middle and far left corner pins The J3 mini jumper should always be in this position regardless of the number you are programming Refer to diag...

Страница 7: ...s then you should ignore this section If you happen to be in a long loop environment which takes more than one second to deliver dial tone on the line then you will need to locate the plastic mini jum...

Страница 8: ...ISSUE 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 8 3 12 PROGRAMMING DIAGRAM FOR THE ADT11 BOARD...

Страница 9: ...OARD CONFIDENTIAL This drawing and all information contained therein is confidential and is the exclusive property of CEECO and may not be copied reproduced or disclosed to anyone in any manner whatso...

Страница 10: ...ll automatically disconnect if you programmed it as such Action Place a call to the telephone from another telephone Reaction The telephone rings Press the CALL button to answer the call The red LED i...

Страница 11: ...ed as it contains required over voltage protection circuitry 6 5 The use of a gas tube station protector is recommended The station ground should not exceed 50 ohms 6 6 Plug the modular line cord from...

Страница 12: ...GE PROTECTION DIAGRAM CONFIDENTIAL This drawing and all information therein is confidential and is the property of CEECO and may not be reproduced or disclosed to anyone in manner whatsoever or used f...

Страница 13: ...ALING DTMF 70ms tone 50ms spacing OUTPUT 4 0 to 6 0dbm ENVIRONMENTAL Temperature o C to 50 C Humidity 20 90 non condensating PROGRAMMING Fifteen 15 hardware mini jumpers DIMENSIONS 6 825 W X 9 76 H X...

Страница 14: ...026 OUTER COVER SECURITY SCREW 1 301 018 MODULAR LINE CORD 1 379 100 FACE PLATE 1 301 054 MODULAR CONNECTOR RJ11 1 570 200 SERVICE MANUAL 1 660 100 CEECO SPK BOARD 1 ADT 11 CEECO AUTO DIAL BOARD 1 602...

Страница 15: ...Telephone Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 9 3 NOTIFICATION TO THE T...

Страница 16: ...ctive unit This information must be inside the shipping container 10 2 DIRECT ALL INQUIRES TO CEECO Repair Department 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net 10 3 NO...

Страница 17: ...or replacement of any part found to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neg...

Отзывы: