11.0   WARRANTY POLICY 

 

 

11.1   GENERAL 

 

CEECO products are guaranteed to be free of defects in material and 
workmanship for a period of 365 days from the date of original purchase.  
CEECO’s obligation under this warranty is limited to repair or 
replacement of any part found to be defective by CEECO. Under no 
circumstances shall CEECO be liable for loss, damage, cost of repair or 
consequential damages of any kind which have been caused by neglect, 
abuse, acts of  GOD or improper operation of equipment. 

 
 

11.2   PRINTED CIRCUIT BOARDS 

 

Printed circuit boards should not be field repaired. If a unit is found to be 
faulty, replace it with another unit and return the faulty unit to CEECO for 
repair.  Modifications by anyone other than CEECO will void the 
warranty. 

 

 

Содержание SSP-560-F

Страница 1: ...DEL SSP 560 F HANDS FREE STAINLESS STEEL TELEPHONE EQUIPPED WITH LOW POWER SPK P C B Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street Engineering Company Okeechobee FL 34972 Voice 863 357 0798 Fax 863 357 0006 ...

Страница 2: ...CO for assistance MODEL NUMBER MODEL SSP 560 F EQUIPPED WITH LOW POWER SPK P C B SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available when calling for technical support CEECO Communication Equipment Engineering Company 519 W South Park Street Okeechobee FL 34972 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco ne...

Страница 3: ...TS SECTION PAGE 1 0 INTRODUCTION 4 2 0 GENERAL 5 3 0 PROGRAMMING 5 4 0 OPERATION 6 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 6 6 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 7 7 0 TESTING 8 8 0 SPECIFICATIONS 9 9 0 PARTS LIST 10 10 0 REPAIR AND RETURN INFORMATION 11 11 0 WARRANTY POLICY 12 ...

Страница 4: ...d maintenance information for the CEECO Model SSP 560 F Telephone The information in this manual is subject to change without notification For information not included in this manual please call or write CEECO Customer Service 519 W South Park Street Okeechobee FL 34972 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net ...

Страница 5: ...s housing by loosening the security screws with the security tool sold separately and removing them 3 2 Locate the blue plastic mini jumpers on the PC board They are used to program the time out disconnect feature 3 3 Place the blue mini jumper at P C board location JP3 in the ON position if time out disconnect is to be used 3 4 If the time out disconnect feature is to be used place the blue mini ...

Страница 6: ...one waits for numbers to be dialed After the call is complete press the button again The RED LED if provided goes out and the call is terminated If the user does not press the CALL button when he or she is finished using the phone then the phone will hang up when the programmed time expires assuming this feature was programmed 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT Volt Ohm Meter 5 16 Nut driver...

Страница 7: ...tion wire into the apparatus box and terminate on the RJ11C terminal block inside 6 6 The use of a gas tube or carbon station protector is recommended The station ground should not exceed 50 ohms 6 7 Plug the modular line cord from the faceplate assembly into the RJ11C terminal block 6 8 Dress the line cable away from the security screws and seat the faceplate into the apparatus box 6 9 Secure the...

Страница 8: ... line Press the CALL button Reaction Dial tone Red LED lights if provided Action Dial a number Reaction The called party answers A normal speakerphone conversation is allowed Action Finish the conversation Press the CALL button or wait until time out occurs Reaction Red LED goes out if provided The call is terminated ...

Страница 9: ...RENT 27ma min 80ma max IMPEDANCE 600 ohms SIGNALING DTMF 70ms tone 50ms spacing OUTPUT 4 0 to 6 0dbm ENVIRONMENTAL Temperature 0 c to 50 c Humidity 20 90 PROGRAMMING Via DTMF keypad DIMENSIONS 10 25 Wide X 13 125 High X 2 625 Depth WEIGHT 16 Pounds RINGER EQUIVALENCY 0 4A TYPE JACK RJ11C UL LISTED NO 6OF5 FCC NO BWBUSA 73021 MT E ...

Страница 10: ...ter Cover Security Screw 1 301 018 Modular Line Cord 1 301 054 Modular Connector RJ11C 1 700 008 Keypad Cable 1 660 000 CEECO SPK Board 1 705 110 Connectorized Keypad 1 6020 Momentary Panel Switch 1 14024 Speaker 1 14067 Microphone 1 391 002 Stainless Steel Panel 1 361 01 Mounting Box 1 12017 Ringer ACCESSORIES 1 301 037 Security Tool ...

Страница 11: ...ective unit This information must be inside the shipping container 10 2 DIRECT ALL INQUIRES TO CEECO Repair Department 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net 10 3 NON WARRANTY REPAIR CEECO will repair equipment out of warranty for a set charge plus parts The customer must pay the shipping costs for both directions 10 4 RETURN FOR CREDIT Material may be returned ...

Страница 12: ... or replacement of any part found to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect abuse acts of GOD or improper operation of equipment 11 2 PRINTED CIRCUIT BOARDS Printed circuit boards should not be field repaired If a unit is found to be faulty replace it with another unit ...