ISSUE 4.0
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
6
6.0 TESTING
6.1
Lift the handset of one of the units that are intended to talk to one another.
The receiving unit should sound the ringer and the lamp should light. Lift
the handset of the receiving unit and determine that normal conversation is
allowed. If so, return the handsets to the cradles. The phone units are
ready for use. If this is a single, ring down unit connected to a C.O. or
PBX line, the call should be automatically placed or connected, when the
handset is lifted.
6.2
If normal conversation does not take place, please review the installation
steps. Make a visual check to ensure that all wires and connectors are as
they should be. Remember that the phone units, which are connected to
the same QLink or ring down line will allow talk paths to one another.
6.3
Once it has been determined that the installation and connections are
correct, and if trouble is still experienced, please refer to section 9.2 of this
manual.
7.0
SPECIFICATIONS
INPUT POWER:
QLink or Central Office or PBX
LOOP CURRENT:
23 ma min. to 80 ma max.
IMPEDANCE:
600 ohms
HEARING AID
COMPATIBLE:
Meets EIA standards
ENVIRONMENTAL:
Temperature 0° C to 50° C
Humidity
20%-90% non-condensating
TELEPHONE COVER:
Brushed 16 ga. Stainless Steel
DIMENSIONS:
4.5" Wide x 4.5" High x 5.0" Deep
(Handset On-hook)
MOUNTING:
Standard double switch electrical box
WEIGHT:
Approximately 3 lb.
FCC REGISTRATION:
BW-88T7-13716-TE-T