PROGRAMMING CONTINUED…
EXAMPLE:
DIAL #00 0106001005
Phone will be set as follows:
DIGIT 1 .. CALL RESTRICTIONS IN EFFECT
DIGIT 2 .. INCOMING CALLS ALLOWED
DIGIT 3 .. ALWAYS 0
DIGIT 4 .. 6 MINUTE TIME OUT
DIGIT 5 .. ALWAYS 0
DIGIT 6 .. ALWAYS 0
DIGIT 7 .. ALWAYS 1
DIGIT 8 .. ALWAYS 0
DIGIT 9 .. ALWAYS 0
DIGIT 10 . 250ms WINK
LOCATION #30 - #69:
(
SPEED DIAL TABLE
)
If speed dialing is desired, enter the desired numbers in any of these 40 locations.
The numbers can range from 1 to 11 digits. Programming is accomplished by
dialing the Location followed by the desired number. All of these locations may
be programmed in a continuous string. Be sure to record your entries in the speed
dial table for future reference.
EXAMPLE:
Enter #3018005551212 in the programming sequence. When in normal
operating mode, the user dials #30 and the phone will Speed Dial 1 800