Cecilware ME-10G Скачать руководство пользователя страница 8

BURNER REMOVAL: The burner can be removed with the unit standing in operating 
position. Turn off the gas flow to the unit. Allow the burner to cool off. Remove the wing 
nut holding the burner to the frame. Pull down the free burner end, enough to clear the 
threaded stud and pull the burner horizontally away from the manifold orifice. The 
burner can now be cleaned or replaced. To reinstall reverse the above procedure. 

 

BURNER MAINTENANCE: The burner should be cleaned both inside the venturi 
portion and on the outside using a soft bristle brush. The burner must be replaced into 
the same position as prior to removal. Once a year a qualified service agency should 
be contacted to inspect the appliance for safe and proper operation.  

8

 

Содержание ME-10G

Страница 1: ...MABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE THIS INSTALLATION MUST CONFORM WITH THE NATIONAL FUEL GAS CODE ANSI Z223 1 LATEST EDITION WARNING IMPROPER INSTALLATION ADJUSTME...

Страница 2: ...on Minimum clearance from combustible construction 8 from back and 6 from side 9 Boiler must be disconnected from gas supply during any pressure testing of pipelines in excess of 1 2 psig and isolated...

Страница 3: ...n must conform with State and Local Codes or in absence of Local Codes with the National Fuel Gas Code ANSI Z223 1 a latest version AIR SUPPLY AND VENTILATION Adequate ventilation and air supply must...

Страница 4: ...4 ME 10 15G AUTOMATIC WATER BOILER PARTS ILLUSTRATION...

Страница 5: ...161A F161A 26 WASHER SS P813A P813A 27 REDUCING COUPLING 1 4 X 3 8 J041A J041A 28 ORIFICE BRACKET U674A U674A 29 SIDE BOX RZ16A RZ16A 30 SLIDE UB12A UB12A 31 THERMOSTAT L622A L622A 32 THERMOPILE F178A...

Страница 6: ...inch outside diameter copper tubing to connect the unit to the water supply line The water line must have a shut off valve supplied by a plumber At the unit connect the tubing to the compression wate...

Страница 7: ...urner see section on removal and cleaning FOR QUALIFIED SERVICE PERSONNEL ONLY THERMOSTAT CALIBRATION Turn the thermostat knob to 10 and remove knob without moving the thermostat shaft Place narrow bl...

Страница 8: ...ud and pull the burner horizontally away from the manifold orifice The burner can now be cleaned or replaced To reinstall reverse the above procedure BURNER MAINTENANCE The burner should be cleaned bo...

Отзывы: