Cecilware ME-10E Скачать руководство пользователя страница 2

ASSEMBLY:

 The four legs, faucet, float ball, and vent cap drain are packed 

separately with the water boiler. Install legs by tilting the water boiler on its side 
and screwing the legs into the leg supports until hand tight Carefully right the unit 
and install it in its permanent location, being sure to leave at lest 6" on the right 
side of the water boiler for access to the controls. Level the unit by adjusting the 
bottom pad of the legs. Screw the ball float (36) onto the end of the water inlet 
valve rod (35). Place the vent cap (30) into the recess in the top of the unit. Mount 
the faucet assembly onto the shank (13). 

GENERAL SPECIFICATIONS

 

DIMENSIONS (INCH)

 

MODEL NO.

 

WATER CAP. IN  

GALLONS

 

A

 

B

 

C

 

D

 

SHIPP. 

WT.(LB)

 

ME-10E

 

10.0

 

14

 

16

 

22.5

 

25.5

 

45

 

ME-15E

 

15.0

 

14

 

16

 

27.5

 

30.5

 

50

 

ME-30E

 

30.0

 

29

 

14

 

22.5

 

25.5

 

95

 

 

 

2

 

Содержание ME-10E

Страница 1: ...ter installation This warranty does not apply under the following conditions neglect or abuse of equipment excessive lime condition Improper installation any outside modification to equipment Every Ce...

Страница 2: ...o leave at lest 6 on the right side of the water boiler for access to the controls Level the unit by adjusting the bottom pad of the legs Screw the ball float 36 onto the end of the water inlet valve...

Страница 3: ...t be performed by a qualified serviceman 1 and 3 phase hook up Remove the fasteners on the cover and slide off cover Install a suitable conduit and connect copper wires to terminal L1 and L2 and L3 fo...

Страница 4: ...lary tube 7 Install new thermostat Position capillary end of thermostat bulb two 2 inches from inside wall 8 Tighten large packing nut then small capillary nut DO NOT over tighten since this could dam...

Страница 5: ...n Still no reading replace Hi Limit switch Water fails to heat Thermostat Pilot light should be on when thermostat is in the full on position 5 position If not replace thermostat and recalibrate see c...

Страница 6: ...phase VOLTS 208 240 50 60 HZ WATTS 7900 10500 AMPS 22 25 PHASE 3 ME10E 15E 120V 208 240 V 1 phase VOLTS 208 240 50 60 HZ WATTS 5300 7000 AMPS 25 5 29 2 PHASE 1 120 Volt Hook Up VOLTS 120 50 60 HZ WAT...

Страница 7: ...J11 1 ME 10 15 E WATER BOILER PARTS ILLUSTRATION 7...

Страница 8: ...ermometer L007A L007A 34 Stem Valve M0251 M0251 15 Chrome Plated Nut NPT K110A K110A 35 Adapter 20 M0589 M0589 16 Body R479A R480A 36 S S Float 3 M0892 M0892 17 Legs set of 4 M005S M005S 37 Knob M027A...

Отзывы: