Cecilware FE-100G Скачать руководство пользователя страница 9

3.

 

Open the control box and disconnect the two pump wires from the 
quick disconnect terminals. 

4.

 

Loosen union fittings on pump and remove pump from urn. 

5.

 

Replace pump and follow priming instruction.  

NOTE: Pump and motor assembly is factory lubricated for the life of the 
pump. 
 

 

TIMER SOLID-STATE 

 
Depress BREW button, hold for approximately 10 seconds, and then 
release. If water flows from spray head when button is depressed and 
stops flowing after button is released, then timer is faulty and should be 
replaced. No water from spray head when button is depressed, indicates 
BREW button is fault and must be replaced. 
 

 

AGITATOR 

 
OPERATION: The agitator pump circuit is programmed to operate when 
the BREW button is pushed. Upon completion of the pump cycle, the 
agitator pump will pump air through the manifold into the coffee gauge 
glasses and into the coffee liner. The completed cycle will take 
approximately 20 second. The agitator may be operated independently 
of the brewing cycle, if the agitator button is depressed. 
 
MAITENANCE: The air pump is capable of delivering enough air for 
proper blending. However if enough agitation is not present, check 
flexible tubing on top of gauge glasses and fittings, for possible air leaks. 
If air pump does not operate on completion of brewing cycle or when 
agitation button is depressed, replace air pump or solid state agitator 
timer (black box). 
 

 

BURNER MAITENANCE 

 
The two main burners can be removed by first removing the base cover 
panel and unfastening the burner ends. The main burners should be 
cleaned both inside the venturi portion and on the outside using a soft 
bristle brush. The main burners must be into the same position before 
removal. Once a year, a qualified service agency should be contacted to 
inspect the appliance for safe and proper operation.  
 

IN

O

N

F

I L

O

P

T

F

O

      PILOT ADJUSTMENT CAP

 

 

SAFETY PILOT:  

 
Remove pilot adjustment cap on 
the gas valve and turn adjustment  
screw to provide properly sized  
flame (3/4 inch long). 
Replace the cap. 

 

9

Содержание FE-100G

Страница 1: ...MABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE THIS INSTALLATION MUST CONFORM WITH THE NATIONAL FUEL GAS CODE ANSI Z223 1 LATEST EDITION WARNING IMPROPER INSTALLATION ADJUSTME...

Страница 2: ...Code ANSI Z223 1 latest edition 6 Provide adequate air supply and ventilation 7 Provide adequate clearance for air openings into the combustion chamber 8 Provide clearance for servicing and proper op...

Страница 3: ...pper tubing Construction Type 304 18 8 Stainless Steel Shipping Wt 125 lb INSTALLATION AND OPERATING INSTRUCTION PRE INSTALLATION INSTRUCTIONS The installation of your coffee urn must be made by a lic...

Страница 4: ...to it Check with your local Gas Company as to proper pipe size Sealant on all pipe joints must be resistive to propane gas Before attempting to light the coffee urn check all joints for gas tightness...

Страница 5: ...LE BLACK J015A 8 1 4 COMP FITTING K039A 9 1 4 ALUM PILOT TUBE H350A 10 3 8 X 3 8 NPT L COMP FITTING K635A 11 3 8 ALUM GAS VALVE TUBE H349A 12 THERMOSTAT RX 2051 12 L622A 13 WIRING HARNESS CH32A 14 8 3...

Страница 6: ...erature Brewed coffee should not be held for longer than one hour it should never be reheated if allowed to cool and it should never be boiled TIMER An electronic solid state timer is used to control...

Страница 7: ...from urn Sediment may be removed by inserting a pipe cleaner through small hole in valve If maximum setting of timer fails to deliver enough water check water pump OUTSIDE SERVICE Should you require...

Страница 8: ...may become necessary to clean out float container to keep float switch in proper operating condition 1 Remove float can cover from top of control box exposing ball float and stem 2 Lift ball from stem...

Страница 9: ...ximately 20 second The agitator may be operated independently of the brewing cycle if the agitator button is depressed MAITENANCE The air pump is capable of delivering enough air for proper blending H...

Страница 10: ...24 PILOT ASSEMBLY NAT F135A F135A PILOT ASSEMBLY LP F134A F134A 25 ORIFICE NAT F160A F160A ORIFICE LP F161A F161A 26 WASHER SS P813A P813A 27 REDUCING COUPLING 1 4 X 3 8 J041A J041A 28 ORIFICE BRACKE...

Страница 11: ...51 SILICONE GASKET M256A M256A 52 STEM VALVE M0251 M0251 53 ADAPTER 1 4 20 M0589 M0589 54 FLOAT SS 3 M0892 M0892 LP CONVERSION KIT L347P L347P 55 WATER GAUGE ASSEMBLY D020A 56 FAUCET ASSEMBLY D017A D0...

Отзывы: