
Thermostat Instructions
FOR AUTHORIZED SERVICE PERSONNEL ONLY
~
**SERVICE INSTRUCTIONS** and **TROUBLE SHOOTING GUIDE**
CAUTION: DISCONNECT POWER BEFORE ATTEMPTING ANY ELECTRICAL REPAIRS
Note:
The thermostat adjustment knob (Item 15) is located in back of top box. If water temperature is less than 197°F (92°C) slowly tum thermostat knob clockwise
until ready light goes out. When temperature of water approaches 197° to 203°F (92° to 95°C) slowly turn thermostat knob counter-clockwise until the green ready
light comes on. If water temperature cannot be increased when thermostat knob is turned fully clockwise, then proceed as follows:
Remove Bracket and pull off knob. Place a small screwdriver into the center of thermostat shaft. While observing green ready light and temperature on thermometer,
hold shaft and turn small adjustment screw in center counter-clockwise until green ready light goes out. When temperature of water approaches 197°-203°F (92°-
95°C), slowly turn screw clockwise until ready light comes on. Turning screw clockwise lowers temperature; counter-clockwise raises ~. After adjusting center screw,
place nail polish or glyptol on screw to set in pos~ion.
Note:
As a final check, measure water temperature at Spray Head (25, Fig 3). Temperature should be 197° to 203°F (92° to 95°C).
TIMER ~DJUSTMENTS
(Automatic Models BT2A, BT3A)
Note: Timer adjustment knob is located in back of top box. To increase volume of water, turn knob of timer clockwise. To decrease, turn knob counter-
clockwise. Turn knob by small increments.
Note: Timer must go through a complete cycle before another adjustment can be made. Timer cannot be adjusted once it has been initiated.
PROBLEMS WITH WARMER ELEMENTS
&
SWITCHES:
If warmer plate fails to heat, first check power source and then check ~ light on warmer switch (21 Fig 3) is lit when in the "1" position. If warmer
switch is lit, replace warmer plate by unplugging brewer, removing the two hold down ~rews on plate and withdrawing warmer plate from brewer.
Replace the new warmer plate. If warmer switch does not light, replace it. To remove sw~ch press each tab behind front plate of brewer down with
screwdriver in turn. As each tab is pressed, pop that corner of warmer switch out of the front of brewer. New sw~ch snaps in from the front.
IF WATER FAILS TO HEAT:
1. If Red power light (20 Fig 3) and warmer switches do not come on, check power source. Replace fuse or reset circuit breaker if necessary. If power
is good, check rear power switch for continuity and replace " switch stays open.
2. If water still fails to heat, disconnect line cord and check out tank heater (31 Fig 3), thermostat (14 Fig 3) and high temperature safety shutoff (54
Fig 3). Replace needed parts.
MAINTENANCE ON AUTOMATIC MODELS BT2A. BT3A
IF NO WATER COMES FROM SPRAY HEAD AND POWER TO BREWER IS
PRESENT CH~~
1.
Water
Supply line 3. Solenoid
2.
Strainer/Filter
Timer
TESTING SOLENOID AND TIMER
Make sure brewer is proper1y primed . Tum on power switch and then warmer switch above funnel Press brew switch and hold for one minute. "
solenoid buzzes and wate flows through spray head when brew necessary. " brew switch and wiring are okay, solenoid is at fault.
REPLACING SOLENOID, TIMER, HI-UMIT, THERMOSTAT AND TANK HEATER
(See 111.3)
Unplug Power Cord, shut off water supply (for automatic brewers) and remove top cover
Solenoid
(Item 1 )- Remove electrical connections, (2) screws, water inlet fitting and silicone tubing. Replace with new solenoid.
TImer
(Item 13) -Loosen and remove (2) screws in back of top box. Lift out timer and disconnect the color coded wires one by one and connect same
to replacement timer. Place pointer of knob to center and dial range
HI.Limit Switch
(Item 54)- Disconnect the (2) push-on leads, loosen large nut on heating element terminal and pull out hi-Iimit bracket (Item 53).
Replace switch (Item 54).
Thermostat
(Item 16)- Remove water tank insert (Item 40), thermostat bulb clip (Item 48), hex nut (Item 42) from capillary tank fitting, thermostat knob
guard (Item 14), and (2) screws securing thermostat to housing. Disconnect the push-on leads and remove thermostat. Replace with new one in
reverse order. When installing new control, do not overtighten small packing nut on compressio fitting.
Tank Heater
(Item 32)- Remove tank insert (Item 40), bulb clip (Item 48), (2) l-ex nuts and washers. Disconnect push-on leads Replace in reverse
order
3
Содержание BREW TIME BT2-2
Страница 4: ...Fig 1 REPLACEMENT PARTS UST FOR BT SERIES BREWERS 4...
Страница 6: ......
Страница 8: ...N203A...