6.1.
Periodic maintenance
frequency
intervention
Hazard
After a day’s
work
Leave the machine for a few seconds to
remove any residual material.
Compressed air to clean the work area
after turning off the machine.
Risks of getting cut
This operation to be
carried out by qualified
personnel.
Always use safety wear
(gloves, goggles, etc)
Weekly
Check the cutting parts of the machine
(blades) and replace them if necessary.
Every
2000
hours
Check the correct fitting of the
components of the machine
7.0. INACTIVITY
7.1.
Preparation of the stop.
This operation can be carried out by the operator.
In anticipation of a long inactive period of the machine, you should take
precautions because they do not lead to hazardous situations when
eventually starting it up;
A long break is considered a period of complete inactivity exceeding one month.
Therefore, you must:
•
Disconnect the equipment from the power source
•
Check the machine thoroughly and replace worn or damaged parts
•
Check the status of the screws and bolts
•
Perform a thorough clean and lubricate all moving parts
•
Cover the machine after it has been stationed in a protected environment
Finding it in perfect condition when using it again,
will only benefit the user.
7.2.
Restarting
This operation must be performed by a qualified technician.
Ensure that the protective devices are efficient, clean the
machine, to remove any deposits of dust and then lubricate
moving parts as well as checking the oil level (for Models TRI H 6.5).