Cebora POWER ROD 1350 Скачать руководство пользователя страница 11

CEBORA S.p.A.

11

3.302.050

22/12/00

3.4

 

- Error codes.

3.4.1

 

- Yellow led (B) lit, with fix light.

Alarm for temperature above limits.
The thermostat is located on the dissipater of the power mosfets of the power board (15).
The power source delivers no current, but the fan remains in operation; we therefore

recommend leaving the power source powered in case of alarm for overtemperature.

Check the temperature of the dissipaters of the power modules on the power board (15), and if

necessary wait for them to cool completely. If the alarm persists, replace power board (15). If the
alarm is reset, check the efficiency of ventilation, make sure the ambient temperature is not too
high, and that the working cycle is not greater than the one specified.

3.4.2

 

- Yellow led (B) flashes at 50%.

Alarm for high supply voltage, greater than approximately 290 Vac, at start-up.
The power source delivers no current.
The power source returns to operation, when the voltage becomes lower than approximately

285 Vac.

This system also protects the power source against accidental power supply at 400 Vac. In

this condition the electronic circuits are protected, but the fan is subjected at mains voltage, can
be damaged in few seconds.

3.4.3

 

- Yellow led (B) off, during first 3 seconds after start-up (no lamp-test).

Alarm for low supply voltage, less than approximately 180 Vac, at start-up. The power source

delivers no current, also if leds signaling status is the same of normal operation after lamp-test.

The power source returns to operation, with the normal  pre-charge sequence, when the

voltage becomes greater than approximately 185 Vac, remaining at reduced performance levels
until the voltage approaches the rated value.

3.4.4

 

- Yellow led (B) flashes (two fast flash with 1,5 seconds pause).

Alarm for low supply voltage, less than approximately 160 Vac, during operation.
The power source delivers no current.
The power source returns to operation, when the voltage becomes greater than respectively

165 Vac approximately, remaining at reduced performance levels until the voltage approaches
the rated value.

3.4.5

 

- Yellow led (B) flashes (three fast flash with 1,5 seconds pause).

Alarm for inside driver circuits supply voltage excessive. This is generally a phenomenon

which may damage the power source if you continue working.

To restore operation, shut off the power source, wait for the capacitors inside to discharge

completely (4 minutes), and restart the power source at the rated voltage.

If the alarm returns, replace the power board (15).

Содержание POWER ROD 1350

Страница 1: ...CEBORA S p A 1 3 302 050 22 12 00 POWER ROD 1350 POWER SOURCE art 249 SERVICE MANUAL...

Страница 2: ...values 8 3 3 4 In open circuit operation the output voltage is not regular 9 3 3 5 In resistive load operation the output voltage is not regular 9 3 3 6 In TIG arc unstable welding irregular 10 3 4 Er...

Страница 3: ...em with original Cebora spare parts 1 3 Safety information The safety notes provided in this manual are an integral part of those given in the Instruction Manual Therefore before working on the machin...

Страница 4: ...current voltage adjusted according to welding needs The welding current is regulated by the microprocessor of the power board 15 based on the signals received from the potentiometer on the front pane...

Страница 5: ...n of the output terminals output and power supply cables of the power source replace if damaged Check the condition of the internal power connections and connectors on the electronic boards if you fin...

Страница 6: ...itch F lit Fan 16 running yellow led B and green C lit lamp test After three seconds yellow led B off output voltage generation starts NO see 3 3 1 3 3 2 3 3 3 3 3 4 YES WARNING DURING THE FOLLOWING T...

Страница 7: ...actions the operator must perform in order to solve the problems solutions 3 3 1 The power source does not start control panel off MAINS SUITABILITY TEST q No voltage for mains protection NO YES Elimi...

Страница 8: ...5 Eventually connect fan 16 directly at the switch 5 3 3 3 Power source powered display and signals doe not indicate the correct values LAMP TEST q Upon start up leds yellow B and green C lit for firs...

Страница 9: ...ing tests use a resistive load capable of withstanding the maximum power source current The appropriate values are shown in the table For better precision voltage measuring in this test must be carrie...