![Cebora POWER PLASMA 3100 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/cebora/power-plasma-3100/power-plasma-3100_service-manual_2577554026.webp)
CEBORA S.p.A.
26
3.302.089
31/05/02
5.5
- Panel board (31) code 5.602.124.
5.5.1
- Topographical drawing.
5.5.2
- Connector table.
Connector
Terminals
Function
J1
1,2
+5 Vdc board power supply input.
J1
3,4
+13,8 Vdc board power supply input.
J1
5
“mains voltage” signal input.
J1
6
relay2 command output (selector switch for 115/230 Vac operation range).
J1
7
relay1 command output (end pre-charge).
J1
8
“power board (35) output current” signal input.
J1
9
“PWM” signal output for power mosfet.
J1
10
“output current reference” signal output.
J1
11
“start from output current check” signal input.
J1
12
board analog circuits 0 Vdc power supply input.
J1
13,14
board digital circuits 0 Vdc power supply input.
CN1
1 – 4
input from pressure switch (32).
CN1
2 – 3
input from thermostat on power board (35).
CN2
1
gas solenoid valve (20) relay command output.
CN2
2
HF relay command output.
CN2
3
board digital circuits 0 Vdc power supply output.
CN2
4 – 5
“start” command input.
CN2
6,7
+13,8 Vdc board power supply output.
CN2
8
“transfer arc” signal input from reed on HF board (22).