PROGRAMMING MODE.

Electronic purse with Chip Card

DA-06

DA-06

EN

G

LIS

H

.

E L E C T R O N I C C I R C U I T S

 

Balances recording.

 With the DA-06 you can record each card with data concerning the access previously 

mentioned, but you can also charge or recharge balances in each cards, up to a maximum of five balances. 
Later the user will be able to consume them according to its needs. 
In order to record balances in a card, firstly you have to configure the dips on the Credits/Time battery the 
number of wished balances. See fig 9 

Accede to the Programming Mode placing DIP 8 of the CONTROL battery in ON Position. Place also DIP 5, 
(Balances Recording) in ON. The rest of dips, except 6, must to remain in OFF position. LED ~PRG~ will blink if 
this operation correctly done. 
Then, insert the card in the reader and presses the Enter key. Like in the previous function, LED ~CONFIRM~ will 
illuminate and you have 5 seconds to confirm the order pressing again the same key. After the confirmation, 
LED ~CONFIRM~ will blink during the recording and finally LED ~OK~ will be illuminated indicating the correct 
balances recording in the card. 

To activate the Serial number through card data

. In the corresponding section it is described how to activate 

serial number through the Data battery. However, it can be necessary to initialize the DA-06 with the same serial 
number than a card previously recorded.  
To do this, you must reach the Programming Mode. Remembers that you have to place the DIP 8 of the 
Control battery in ON Position. Place also DIP 7 in ON. The rest of dips, except 5 and 6, have to remain in OFF 
position, LED ~PRG~ will blink if this operation correctly done. (The rest of dips except 5 and 6 must to be in 
OFF. 
Then insert the previously recorded card and press the Enter key. Like in the rest of previous functions, 5 sec the 
Led ~CONFIRM~ will be illuminated and you have 5 sec. to confirm the order pressing Enter again; after the 
confirmation, LED ~CONFIRM~ will blink during the module's configuration with the new serial number. Finally 
LED ~OK~ will be illuminated indicating the correct result of the operation. If there was some problem avoiding 
to activate the serial number, the LED ~ERROR~ will indicate it, briefly illuminating. 
Remembers that each time you activate a serial number, data previously stored in the circuit will be erased. 
Note. Remember that if you activate you activate a serial number, the rest of data stored in the module, like 
card numbers, etc… will be irrevocably erased. 

Combined use of several D0A-06

. There are applications requiring several DA-06 installed in different places, 

but that all of them must to be compatible. Therefore, with a same card you could activate the access in 
some modules whereas in another no.  Moreover, you could have cards with access to all the readers and 
others only with access to some readers. All this without using a different card type for each reader. 
To manage a system composed by several DA-06 and to activate them between them, firstly you have to 
assign to each one the same serial number. This operation can be done activating the serial number in a first 
circuit and with a card recorded by this one to initialize the rest of DA-06, or through the DATA battery Data 
repeating the same process code the serial number activation in all of them. In any mode the result will be the 
same. 
Later, and with cards recorded with its corresponding identifier number you have to manage in which modules 
and which cards will have access to each of them. For instance, if you wish that a card can be used as key for 
a system composed by five DA-06, you have to activate each reader: if you needs that a card only has 
access in a couple of them, you have to activate it in these two modules and no more. Thus, the balances 
consumption will be subject to have access in the corresponding DA-06. 
This “Levels” system is the used one in gymnasiums with different accesses to the different services, companies 
with different privileges under payment, etc. 

ACCESS CONTROL & BALANCE MODE.

The balance and access control mode configure the circuit to do a single function: to read the introduced 
card, to deny or accept the access according to its registry in the circuit memory and if this one has balances, 
to consequently activate the relay output during the selected time. In any case it will accept programming 
functions. 
In order to establish the DA-06 operating in Balances and Access control mode Control, check the DIP 8, 
(Programming), of the Control battery one is in OFF Position. The module will confirm this situation extinguishing 
all Leds on the main board. From this moment, the module will exclusively operate as Balances and Access 
control device.

Time per Balance.

 Each time the user will consumes a balance, the exit will be activated. The time that this 

one remains connected will depend on the previously assigned time per balance. 
The time selection per balance can be only done in the Balances and Access control device mode, through 
the dips of the Credit/Time battery. 
The module admits a time per balance: 1 minute as minimum and of 120 minutes as maximum. See fig 10 
and configure the Dips battery the wished time. 

Balances Consumption

. In order to activate the circuit output, firstly the user have to introduce the chip card 

in the reader, and then to press the Enter key. Automatically the circuit will discount and consume a balance 
from the card, activating the output during the pre-assigned time per balance. 
Later the user will be able to remove the card, the output will not be deactivate up to the end of the timing. 
Until then, the module will not accept the consumption of a new balance. 
During the consumption of a balance, the state Leds, initially lighted on will be progressively lighted off 
according to the time up to the end of the balance. 
Each one of these five Leds will indicate with 20%, 40%, 60%, 80% and 100%, the consumed percentage. A 
complementary illuminated Led indicates that the indicate percentage is still available. An intermittent LED 
will indicate that half of that percentage has been consumed, and a lighted off LED will indicate that this 
percentage has been consumed. 

Indication of balances and cards state

. When the user introduces a chip card in the DA-06, if it wasn't be 

previously activated, the LED Error blinks until you remove the card from the reader. If at the opposite the card 
was previously activated, the module remains you press Enter and start the consumption of a balance. 
Each time you press Enter, if the card has no balance, the five state leds will blink until the card is removed 
from the reader. 
If the card had balances, when Enter is pressed the module will initially indicate how many balances are 
available in the card illuminating the corresponding number of state Leds. When Led OK on the main board is 
lighted off, state Leds will change their indication to indicate the time of the balance consumption. 

Fig. 10 To select time per Balance

1min

5 min.

40 min.

80 min

2min

10 min.

50 min.

90 min

3min

20 min.

60 min.

100 
Min

4 min

30 min.

70 min.

120 
Min

DO NOT FORGET.

In the different module functions, you have to check you have placed dips battery as it is indicated in the 
corresponding instructions. Selecting by error more than one DIP will provoke an incorrect operating mode of 
the function you want to execute. 
Do not remove, extend or modify the communication cable between the main board and the reader. 
Otherwise, the module doesn't operate correctly and the warranty will be cancelled.  
In the module installation, this one must to be insulated from devices that can provoke interferences or network 
parasites. Use, if necessary, a network filter and place the circuit in a protected place, far away from these 
disturbances. 
Do not bend, twist nor dirty cards chip, otherwise can irremediably damage them. 
Maintains cards far from direct sun, like car dashboard, windows, or any other place that the excess of heat 
can deform the card. 
Protects the chip installed on the card from elements that can shred or destroy the copper part composing it. 
Do not place the reader in a place where it is not protected from the rain or extreme humidity, because it 
doesn't have protection against such elements 
The damage because of the failure or omission of these considerations, as well as an incorrect manipulation 
will be exempt of the module warranty. 

Fig 9. To select Balances

1 Balance

2 Balances

3 Balances

4 Balances

5 Balances

GENERAL WIRING MAP.

Module

FE-103

Led

Mín.

Máx.   

Power Supply

L

Input

N

Mains

Switch

230 V.A.C.

Fuse

100 mA.

Transformer

Power

Enter

Control

Work

O

u

tp

u

t

NO

Common

NC

20%

40%

60%

80%

100%

State Leds board

Communication cable

Reader - Main board

Data

DA-06

Module

Credit/Time

MSB

LSB

Prg
Valid
Error
Ok

Reader Circuit

1 2

   3

   

4  

5  

6 7

  8

 9

 1

0

 

11

 

12

1 2

   

3  

 4

O

N

1  2  3  4

O

N

DIP SWITCH

Отзывы: