The cabling used for the electronic circuit must be supplied by the
manufacturer. Under no circumstances may extensions be used.
9. Installation
STEP 10
STEP 11
Connect the equipment outlet to
the auxiliary tap, and the other
end to the MIAWA outlet (white/
neutral pipe).
Effect the electrical connec-
tions to the equipment and
then connect to the mains
power. The auxiliary pump is
used when the inlet pressure
is insufficient.
1 - 24V transformer
2 - MIAWA programmer
3 - Optional auxiliary pump
STEP 1
STEP 2
STEP 3
Drill a hole in the sink top using a
19mm bit.
Pass the tap through this hole.
Install the tap as shown in the
figure, in the same order.
STEP 4
STEP 5
STEP 6
Disconnect the mains cold water.
Install the 3 way valve into the
mains cold water supply.
Make a hole in the sink drain
using a 7.2mm bit.
Prepare this hole for the
equipment drain.
Connect the 3-way valve inlet to the
MIAWA connector (blue pipe) using
the pressure reducer.
Connect the equipment drain (red
pipe) to the sink drain.
STEP 7
STEP 8
STEP 9