CE+T Power e-one 10 - 48/230 Скачать руководство пользователя страница 6

3. Warranty and Safety Conditions

*

WARNING: 

The electronics in the power supply system are designed for an indoor, clean environment. 

When installed in dusty and/or corrosive environment, outdoor or indoor, it is important to:

 

Install an appropriate filter on the enclosure door, or on the room’s air control system.

 

Keep the enclosure door closed during operation.

 

Replace the filters on a regular basis.

Important Safety Instructions and Save these Instructions.

 

The inverter system/rack can reach hazardous leakage currents. Earthing must be carried out prior energizing 
the system. Earthing shall be made according to local regulations.

 

Prior to any work conducted to a system/unit make sure that AC input voltage and DC input voltage is 
disconnected. 

 

CAUTION

 – Risk of electric shock. Capacitors store hazardous energy. Do not remove cover until 5 minutes after 

disconnecting all sources of supply.

 

CAUTION

 – Disconnection of the DC source is required to de-energize this unit before servicing. 

 

Maximum operating ambient temperature is 40º C (104º F).

 

AC and DC circuits shall be terminated with no voltage / power applied.

 

Some components and terminals carry high voltage during operation. Contact may result in fatal injury.

 

Warning labels must not be removed.

 

Never wear metallic objects such as rings, watches, bracelets during installation, service and maintenance of 
the product.

 

Insulated tools must be used at all times when working with live systems.

 

When handling the system/units pay attention to sharp edges.

 

ESD Strap must be worn when handling PCBs and open units.

 

The inverter system/rack is not supplied with internal disconnect devises on input nor output.

 

REG systems can be seen as independent power sources.

 

In case of output short circuit, the inverter must disconnect in maximum 15 seconds. However, an external 
protection must be provided in order that the short circuit protection operates within 15 seconds. 

 

The equipment must be installed and commissioned by skilled technicians according to instructions in this 
manual.

 

Local regulations must be adhered.

*  These instructions are valid for most CE+T Products/Systems. Some points might however not be valid for the product described in this manual.

Warranty and Safety Conditions

– e-one 10 - 48/230 - User manual - v1.2

Содержание e-one 10 - 48/230

Страница 1: ...NTEGRATION BEYOND THE INVERTER THE NEW GENERATION OF POWER CONVERTERS e one 10 48 230 User Manual V1 2 Copyright 2013 Construction electroniques telecommunications S A All rights reserved The contents...

Страница 2: ...cabinet 11 5 3 2 Wall mounting 11 5 4 Wiring 12 5 4 1 e one 10 48 230 Front view 13 5 4 2 Disconnecting and protecting devices 13 5 4 3 Grounding 16 5 4 4 Remote Monitoring and Control 16 6 Getting s...

Страница 3: ...Version Release date DD MM YYYY Modified page number Modifications 1 0 27 06 2018 First release of the Manual 1 1 07 12 2018 Amendment and correction 1 2 21 11 2019 New layout 3 e one 10 48 230 User...

Страница 4: ...C backup solution that unlike most used UPS s Maximizes the operator s applications uptime Operates with lowest OPEX Provides best protection to disturbances Optimizes footprint Our systems are Modula...

Страница 5: ...Alternating current DC Direct current ESD Electro Static Discharge MET Main Earth Terminal USB Universal Serial Bus PE Protective Earth also called Main Protective Conductor N Neutral PCB Printed Cir...

Страница 6: ...104 F AC and DC circuits shall be terminated with no voltage power applied Some components and terminals carry high voltage during operation Contact may result in fatal injury Warning labels must not...

Страница 7: ...air filtering must be taken 3 1 Handling The cabinet shall not be lifted using lifting eyes Remove weight from the cabinet by unplugging the inverters Mark inverters clearly with shelf and position fo...

Страница 8: ...number T551730201 Cooling Audible noise Forced cooling with FAN speed control 65 dBA at 1 meter MTBF 200 000 hrs Peak Efficiency DC AC 91 Dielectric strength DC AC 4300 Vdc RoHS Compliant Vibration GR...

Страница 9: ...gainst reverse current 4 35 A at 230 VAC Crest factor at nominal power 2 5 1 With short circuit management and protection 9A 2xIn for 15 s and then no output power from module Transfer time from DC mo...

Страница 10: ...ng accessories are present inside the e one 10 48 230 packaging box S No Accessories Quantity 1 6 3 A Fuse 1 2 Ferrite core 1 3 IEC Male plug 1 4 Connectors DC Alarm Remote ON OFF 3 5 Rack clamps for...

Страница 11: ...ck mounting in 19 cabinet Step A Fix the brackets on both sides of the e one module with M3 screws Step B Place the e one module inside the 19 cabinet horizontally and fix with M6 screws 5 3 2 Wall mo...

Страница 12: ...and upstream breakers or fuses shall be set up in accordance with DC and AC wires ratings to meet the local national electrical code standard All breakers cables and wires should be classified for mi...

Страница 13: ...uit protection with breaking capacity related to short circuit capacity of upstream DC source DC Breaker must be installed close enough to permit easy Break Before Make Appropriate type can be chosen...

Страница 14: ...AC Input Connection By default e one by pass model is designed to operate in DC input If DC input is not available the load is directly transferred to AC input mains Model Iin 230 Vac Cable size e on...

Страница 15: ...anently with a continuous RED indication and Major Alarm is generated So the module stops after 15 seconds of short circuit Bypass Mode Short circuit is protected by AC output Fuse 5 4 2 6 Replacing F...

Страница 16: ...ted to the appropriate terminal Caution Current leakages can reach hazardous values For your personal SAFETY earth connections must be done before energizing the system 5 4 4 Remote Monitoring and Con...

Страница 17: ...onnecting any external voltage on terminal 1 to 3 Maximum wire size is 1 mm Functional table for remote ON OFF function States Pin 1 3 Pin 2 3 System status 1 Open Open System working normally 2 Close...

Страница 18: ...Fast Blinking GREEN DC source is out of range 4 Blinking ORANGE Output Power VA Derating Temperature Derating 5 Slow Blinking RED Inverter output short circuited 6 Fast Blinking RED Module over temper...

Страница 19: ...tched OFF Make sure that all breakers and cables are according to recommendations and local regulations Make sure that all cables are strain relieved Make sure that DC IN polarity is according to mark...

Страница 20: ...terials Enclosure accessories Cables Wound components PCBA etc 8 2 Disposal CE T cannot be held responsible for disposal of the Inverter system and therefore the customer must segregate and dispose th...

Страница 21: ...rules will result not to have all module operating when running on DC Installation and commissioning must be done and conducted by trained people fully authorized to act on installation It is prohibit...

Страница 22: ...DC power supply and switch ON the DC breakers Check if inverters are working properly INFO LED Green Check if inverter is working in By pass mode Check output voltage Check if system has no alarm Swi...

Страница 23: ...range and DC breaker is switched ON DC breakers Check for loose terminations Inverter does not start Check front ON OFF button and Remote ON OFF terminal Inverter only run on AC or DC Check the Voltag...

Страница 24: ...only be performed by properly trained people 11 1 Manual check Measure input voltage DC input AC output with multi meter Replace dust filter if present Take a snap shot of the inverter Maintenance 24...

Страница 25: ...t power com extranet Repair registering guidelines may be requested by email at repair cet power com The RMA number should be mentioned on all shipping documents related to the repair Be aware that pr...

Страница 26: ...13 Appendix 13 1 Electrical Layout Appendix 26 e one 10 48 230 User manual v1 2...

Страница 27: ......

Отзывы: