INSTALLATION MANUAL

EN

Enter programming mode

 

 

Yellow led

Present user card 

Beep + green LED then yellow LED 

Blue LED

Present the master badge

Swipe the master badge or 

wait 10 seconds

 

 

Exit programming mode

To add more cards, repeat step user card 

and step shadow card. 

Present the shadow card

2 beeps + green LED flashing

 

Add user cards (max. 150)

Delete user cards

Enter programming mode 

 

 

Yellow LED

Present the user card or its shadow card

Beep + LED OFF then back to yellow LED

Present again the same card

Beep + red LED then back to yellow LED

Both cards are deleted

Blue LED

 

Present the master badge

Swipe the master badge or 

wait 10 seconds

 

 

Exit programming mode

7.1 Shadow mode

In Shadow mode, two different badges are programmed for the same user. The user 

gets one of the two badges and the second badge is stored in a secure place by the 

system supervisor as a shadow badge. These 2 badges can both grant access. In the 

event that the user badge is lost or stolen, the shadow badge can be used to delete the 

user badge from the STAR1M.

1

ON

2

ON

3

ON

4

ON

ON

OFF

Dipswitch setting

Содержание STAR1M

Страница 1: ...cdvigroup com 1 STAR1M Mullion Mifare standalone controller and card reader Security to Access www cdvigroup com English EN STAR1M Mullion Mifare Standalone Controller and Card Reader ...

Страница 2: ...on Installation recommendations To protect the device from back EMF do not forget to install the varistor across the lock terminals in parallel This product is shipped with a varistor The varistor must be connected directly to the locking system terminals electric strikes electromagnet or lock operated by the device If the device functions with several locking systems each one must be fitted with ...

Страница 3: ... access reader 5 WIRING DIAGRAM C56 C58 C61 1 MM10 4 3 2 1 ON ON ON ON L7 6 Q7 8 R78 P1 1 P3 BZ3 C6 C24 C59 MM1 MM14 CR3 CR10 CR25 CR26 CR24 MM3 MM15 CR12 CR13 CR15 I1 MM16 CR22 P2 CR19 CR21 CR20 CR28 CR27 CR29 R70 R68 R69 R65 C68 CR30 Wire colors Wiring table Standalone mode Wiegand mode Red 12Vdc 12Vdc Black 0V 0V Green Data 0 White Data 1 Blue Normally open Grey Common Purple Normally closed Br...

Страница 4: ...ng for the Master card to be programmed when powering on for the 1st time 7 STANDALONE MODE Mifare compliant ISO 14443A Mifare classic Programming using the Master card directly on the reader Capacity 1 Master card 300 or 150 user cards according to mode 1 door controller 1 relay output N O N C contact 1A 12Vdc 1 request to exit input Compatible with METAL PVP Mifare badges BV cards ISO Mifare cre...

Страница 5: ...e Fail safe 12V DC ADC335 Push button Magnet Strike fail safe Normal operation 1 ON 2 ON 3 ON 4 ON ON OFF Swipe user card Access granted Beep green LED relay activated Access denied Beep red LED Blue LED Position DIP2 to ON The factory setting of the STAR1M is shadow mode For first use please program a master badge see process page 8 ...

Страница 6: ...nt the user card or its shadow card Beep LED OFF then back to yellow LED Present again the same card Beep red LED then back to yellow LED Both cards are deleted Blue LED Present the master badge Swipe the master badge or wait 10 seconds Exit programming mode 7 1 Shadow mode In Shadow mode two different badges are programmed for the same user The user gets one of the two badges and the second badge...

Страница 7: ...e master badge or wait 10 seconds Exit programming mode Enter programming mode Yellow LED Present the user card Beep LED OFF then back to yellow LED Present again the same card Beep red LED then back to yellow LED Blue LED Delete user cards Present the master badge Swipe the master card or wait 10 seconds Exit programming mode 7 2 Standard mode In Standard Mode only one user badge is programmed fo...

Страница 8: ...ock time Enter programming mode Yellow LED Press the push button Each push button press 1 second Blue LED Present the master badge Default value 5 seconds programmable from 01 to 99 seconds 1 ON 2 ON 3 ON 4 ON ON OFF Switch on power supply White Red LED flashing while the memory is deleted Followed by start up sequence Delete all cards reset the reader to the factory default values Switch off powe...

Страница 9: ...rmat 8 MIFARE READER WIEGAND MODE OFF 1 ON 2 ON 3 ON 4 ON ON OFF 1 ON 2 ON 3 ON 4 ON ON OFF 1 ON 2 ON 3 ON 4 ON ON 30 bit Wiegand Output 44 bit Wiegand Output 26 bit Wiegand Output Important Switching shadow mode to independent mode all cards are saved but become independant Switching independent mode to shadow mode all cards are erased ...

Страница 10: ...N MANUAL EN 8 3 LEDs management in CENTAUR 8 2 LEDs management in ATRIUM GREEN ACCESS GRANTED RED ACCESS DENIED BLUE STANDBY LED STATUS GREEN ACCESS GRANTED RED ACCESS DENIED BLUE STANDBY LED STATUS GREEN LED CONFIGURATION RED LED CONFIGURATION GREEN LED CONFIGURATION RED LED CONFIGURATION ...

Страница 11: ...DVI TAIWAN Phone 886 0 42471 2188 www cdvichina cn CDVI SUISSE Phone 41 0 21 882 18 41 www cdvi ch CDVI CHINA Phone 86 0 10 84606132 82 www cdvichina cn CDVI IBÉRICA SPAIN PORTUGAL Phone 34 0 935 390 966 www cdviberica com CDVI ITALIA Phone 39 0321 90 573 www cdvi it CDVI MAROC Phone 212 0 5 22 48 09 40 www cdvi ma CDVI NORDICS SWEDEN DENMARK NORWAY FINLAND Phone 46 0 31 760 19 30 www cdvi se CDVI...