CDVI SHL1200 Скачать руководство пользователя страница 4

4

5

EN

EN

SHL1200

Electromagnetic Shearlock - 1200kg

4

(x2)

1

2

(x8)

3

(x2)

1

2

(x8)

1

(x2)

1

2

(x8)

2

C - Surface mounting (Optional: KSHL Kit)

Fix the magnet on the door and 

place the housings.

Measure  and  mark  the  center 

lines  to  determine  the  magnet 

position  on  the  jamb  and  the 

armature  plate  on  the  door 

leaf frame. Then drill the fixing 

screw  holes  to  fix  the  screws 

easily.

Important: 

The 

surface 

housing  can  be  mounted  in 

horizontal  or  in  vertical  in  the 

secure side.

Mount the brackets of the housing 

on the jamb and on the door leaf. 

Insert  the  cable  and  temporarily 

fix  the  magnet  and  the  armature 

plate  to  the  bracket  of  the 

housing.  Loosen  the  screws  on 

the side of the armature plate (1) 

with  the  Allen  key.  Then  adjust 

the gap between the magnet and 

the  armature  plate  by  adjusting 

the  top  screws  on  the  armature, 

allow  2mm  distance  maximum. 

Tighten  the  2  screws  on  the  side 

of  the  armature  plate  (2)  once 

the  test  on  the  magnet  has  been 

successfull.

+

_

NC
CO
MN
O

5] WIRING DIAGRAM

 *Input voltage: 12V DC or 24V DC

  The magnet can be powered in 12 VDC

  or in 24V DC according to the jumper

 settings.

Terminal block

    +

 

  Input voltage 12V or 24V DC*

 -

 

  Input voltage 12V or 24V DC*

   T=NC

    Normally closed contact

  

C=COM

 Common

   R=NO

   Normally open contact

T

C

R

Insert a flat screwdriver to 

adjust the Time Delay from 0 

to 30 seconds.

Shorten

Содержание SHL1200

Страница 1: ...FR EN 10 WARRANTY YEAR Electromagnetic Shearlock Ventouse lectromagn tique cisaillement 1200kg SHL1200...

Страница 2: ...off springs Form C output monitoring Finish Aluminium steel Build in varistor Operating temperature 25 C to 70 C Input voltage Free voltage 12 24V DC Dimensions Maglock 267 mm L 30 mm W 32 mm D Armatu...

Страница 3: ...ween the magnet and the armature plate by adjusting the top screws on the armature allow 2mm distance maximum Tighten the 2 screws on the side of the armature plate 2 once the test on the magnet has b...

Страница 4: ...e magnet and the armature plate to the bracket of the housing Loosen the screws on the side of the armature plate 1 with the Allen key Then adjust the gap between the magnet and the armature plate by...

Страница 5: ...nctionnement 25 C 70 C Finition Aluminium acier Alimentation Free voltage 12 24V DC Dimensions Ventouse 267 mm L 30 mm l 32 mm H Contre plaque 267 mm L 30 mm l 35 mm H Courant d appel 12V DC 1 8A 24V...

Страница 6: ...ajuster la contre plaque 2 mm de la ventouse Ress rez ensuite les 2 crous de blocage 2 Testez le fonctionnement de la ventouse et de la contre plaque puis fixez les attention les vis de fixation ne so...

Страница 7: ...uster la contre plaque 2 mm de la ventouse Ress rez ensuite les 2 crous de blocage 2 C Montage en saillie Option Kit KSHL Testez le fonctionnement de la ventouse et de la contre plaque puis fixez les...

Страница 8: ...THERLANDS LUXEMBOURG 32 0 56 73 93 00 www cdvibenelux com CDVI GERMANY 49 0 175 2932 901 www cdvi de CDVI TAIWAN 886 0 42471 2188 www cdvichina cn CDVI SUISSE 41 0 21 882 18 41 www cdvi ch CDVI CHINA...

Отзывы: