CDVI ROFU BKC-5000B Скачать руководство пользователя страница 3

Copyright All Rights Reserved ROFU Security International Corp. ROFU BKC-5000B. Published: February 12, 2020

3

Install Crimp Connectors

Crimp connectors included:

Use a pair of crimping pliers designed to crimp insulated connectors.  Place the crimp connctor

into the compression slot.  Be sure the crimping jaws are positioned over the stripped portion of

the wire.  Squeeze the handles together with enough force to crush the end of the butt splice.

Crimp connectors

BKC-5000B Keypads Installation

Template

Flat head phillips screws

Three-point security screw

Anchor bolts

System wiring

Open BKC-5000B Keypad by loosening and removing the back case three-point security

screw at the bottom with the special tool.
Use the provided drilling template to accurately locate and drill the required holes.
Use the screws provided to mount the back case on the wall.  Be sure to draw the

wiring through the large center hole in back case, and keep level.
Connect accurately the system wiring following the label enclosed on the rear.
Put the unit back and screw it on by using the special tool.

Содержание ROFU BKC-5000B

Страница 1: ...larm has been triggered Overhead LEDs and Backlit keys for easy use in the dark Wrong code lockout if an incorrect passcode is entered 3 times in a row the keypad will lock down for 60 seconds Specifi...

Страница 2: ...leted Invalid access Forget to press after entering passcode within 30 seconds Bluetooth device vandalized Door sensor is on LED Status Audible Beeps Status Reset Procedures 1 Power off Access Control...

Страница 3: ...plice Crimp connectors BKC 5000B Keypads Installation Template Flat head phillips screws Three point security screw Anchor bolts System wiring Open BKC 5000B Keypad by loosening and removing the back...

Страница 4: ...ator Note 1 Administrator ID ADMIN can not be changed We recommend changing Admin s default passcode 12345 right after you login as the admin Go to setting page tap Admin Passcode to edit Admin Passco...

Страница 5: ...fault passcode It s important to change your Admin passcode Immediately You can enable Door Sensor when you connect to a closed circuit magnetic sensor or a monitored door lock that has door sensor or...

Страница 6: ...its Tap user CARD FOB to enter assigned 10 digits code printed in card fob Keypad and Card Fob Access can be independently enabled disabled for a user Tap Access Types to choose Permanent Temporary Nu...

Страница 7: ...Back to the main page Tap Auto to enable Auto unlock function to access Figure Tap to go to Device List page as Figure Select the desired Bluetooth Access Control Keypads Readers around you Tap Setti...

Страница 8: ...meters 164ft distance The response time of Bluetooth signal may vary depending on mobile device Add Proximity Card Fob to A User by Reading the Card on The Keypad Add card fob numbers to the ADMIN Ad...