Install Crimp Connectors
Crimp connectors included:
Use a pair of crimping pliers designed to crimp insulated connectors. Place the crimp connctor
into the compression slot. Be sure the crimping jaws are positioned over the stripped portion of
the wire. Squeeze the handles together with enough force to crush the end of the butt splice.
Crimp connectors
BKC-5000B Keypads Installation
Template
Flat head phillips screws
Three-point security screw
Anchor bolts
System wiring
Open BKC-5000B Keypad by loosening and removing the back case three-point security
screw at the bottom with the special tool.
Use the provided drilling template to accurately locate and drill the required holes.
Use the screws provided to mount the back case on the wall. Be sure to draw the
wiring through the large center hole in back case, and keep level.
Connect accurately the system wiring following the label enclosed on the rear.
Put the unit back and screw it on by using the special tool.