READER HEAD CABLING
Each micro reader uses a bespoke PoE (Power over Ethernet) connection to
the ievo Control Board, carrying both power and data. Therefore, you must
use a high-quality shielded Ethernet cable to prevent power and data loss.
Each reader comes provided with a 5m CAT6 SFTP (braid-shielded cable,
foil-shielded pairs) Ethernet cable. If you need to place the reader further
than 5m away from the control board, please use a cable with the following
specification:
• Up to 50m – Cat5e/Cat6a SFTP Stranded-conductor, 26 AWG, with
shielded RJ45 connectors
• Up to 90m – Cat5e/Cat6a SFTP Solid-conductor, 24 AWG with shielded
RJ45 connectors
Note:
Cat7 specification cable is too thick to use for connection to the head.
WIEGAND CABLING
We recommend that you use Belden 9534 (4 Core shielded) cable for the
Wiegand connection between the ievo Control Board and Access Control Unit.
We recommend twisting 2 pairs for Clock and Data and using the shielding
for Ground. The distance between the ievo Control Board and Access Control
Unit must not exceed 25m.
NETWORK
Each ievo control Board requires an Ethernet cable connected back to the
local network.
We recommend using CAT5e shielded cable and the distance must not exceed
90m.
If you are using the ievo Control Board with a Power Over Ethernet (PoE)
module, then the cable between the PoE switch or injector and ievo Control
Board must meet the below specification:
• Up to 50m – Cat5e/Cat6a SFTP Stranded-conductor, 26 AWG, with
shielded RJ45 connectors
• Up to 90m – Cat5e/Cat6a SFTP Solid-conductor, 24 AWG with shielded
RJ45 connectors