background image

Fabricant de Contrôle d’Accès depuis 1985     Manufacturing Access Control since 1985

The installer’s choice

Receiver type: 

Supereheterodyne.

Demodulation: AM/ASK.

Operating frequency: 

433.92 Mhz.

Sensitivity (for good signal): 

-115 dBm.

Input load: 

50 Ohm.

Power supply: 

230 Vac - 50 Hz.

Current consumption 

20 mA @230 Vac 

Relay contacts 

4 x NO/NC.

Max current on relay output: 

16 A.

Memory capacity: 

500 transmitters

Security protocol 

Keeloq® Hopping code

N° of code combinations  

2exp64

Operating temperature: 

from -20 to +70 °C.

Overall dimensions (Fig. 2): 

155 x 118 x 56 mm 

Weight: 

150 gr. 

Relay operating mode 

Pulse, step, timed, on-off

Delay 

from 1 sec. to 24h: 59 min.

Enclosure protection 

IP55 

The receiver Erone type SEL2641R433-XPL4V (Fig. 1) is a AM/ASK single conversion 

superheterodyne receiver with integrated “Keeloq® Hopping code” decryption. 

A special algorithm allows to keep synchronyzed transmitter and receiver.

Power supply: 230 Vac. 

The receiver relays output, can drive many type of loads, up to 16A / 230 Vac.

The transmitter memorization can be carried out either with 2 push-buttons of the receiver 

or remotely, using only the keys of the transmitter. The setup of the remaining parameters 

can be done only with the 2 push buttons of the receiver. All the setting steps are displayed 

by a backlit LCD display. 

The internal data can be saved/restored to/from an external memory.

4 RELAYS RECEIVER SEL2641R433-XPL4V

2

Technical Specifications

3

Mounting

www.erone.com - www.cdvigroup.com

Fig.1

1

Introduction

Drill the placing surface 

with ø6 mm tool and insert the 

2 plugs 

 

Then fix the support with 

the screws provided

 

F1001000093

Fig. 3

Fig. 2

Fig. 1

ERONE

XPL4V

118

155

56

5 x PG11 + 1 PG7 cable 

glands ( provided )

ERONE

XPL4V

Содержание ERONE SEL2641R433-XPL4V

Страница 1: ...erheterodyne receiver with integrated Keeloq Hopping code decryption A special algorithm allows to keep synchronyzed transmitter and receiver Power supply 230 Vac The receiver relays output can drive many type of loads up to 16A 230 Vac The transmitter memorization can be carried out either with 2 push buttons of the receiver or remotely using only the keys of the transmitter The setup of the rema...

Страница 2: ...u 2 Remote from the receiver using a transmitter already in the receivers memory Mode PLUS P1 enter the menu 4 sec or confirm the choice P2 navigate the menu 8 Programming Navigation menu Button activated TX Serial number Relay activated The factory value for the timing is 1 sec Use P1 to scroll the digits and P2 to confirm Relay 1 Pulse Relay 1 Step Relay 1 Timed Menu Timed Add Add transmitters s...

Страница 3: ... first TX Block memorization 10 Menu Config Allows to set the operating mode of each relay as Pulse Step Timed or ON OFF In case of Timed it s possible to set the delay time from 1 sec to 24h 59 min PULSE the relay stays excited as long as the transmitter is activated ON OFF the relay excites if it is pressed the button A of the TX and releases when it is pressed the button B It is enough to memor...

Страница 4: ...ternal Internal Save Restore MEM MEM MEM MEM Allows to create a backup of the memory data base and save it onto an external memory type SEL2641 MXPL fig 6 Plug in the memory in the proper receiver connector The memorization PLUS allows to add a new transmitter remotely without using the push buttons P1 P2 It s enough to use a transmitter Ma ster A transmitter Master can be 1 the first transmitter ...

Отзывы: