CDVI DMR18S Скачать руководство пользователя страница 9

2 EASY

2.Delete Card:

  

ONLINE MONITORS

ONLINE DEVICES

During working at debug 
state,press "1#" to enter 
tools page.

All devices online or 

offline will be showed.

Pres NO. 

to select

*Back

Tools

1.Installer Setup
2.Setup
3.Card Manage
4.Online Monitors
5.Online Devices
6.Voltage Measure

> >   D e b u g   S t a t e   < <

0-#                 Redial

1-#                 Tools

2-#                 Exits

* Cancel

# Save

4. Online Monitors

(Search Range)

Gateway:[  ]
IM:[  ] ~ [  ]

Pres NO. 

to select

*Back

Tools

1.Installer Setup
2.Setup
3.Card Manage
4.Online Monitors
5.Online Devices
6.Voltage Measure

> >   D e b u g   S t a t e   < <

0-#                 Redial

1-#                 Tools

2-#                 Exits

* Cancel

# Save

5. Online Devices

[CDS1]: Online
[CDS2]: Online
[CDS3]: Fail
[CDS4]: Fail

Pres NO. 

to select

*Back

Tools

1.Installer Setup
2.Setup
3.Card Manage
4.Online Monitors
5.Online Devices
6.Voltage Measure

> >   D e b u g   S t a t e   < <

0-#                 Redial

1-#                 Tools

2-#                 Exits

* Cancel

# Save

[ - - ]

6. Voltage Measure

* Cancel

# Save

Show The Card

2. Delete By Card

* Cancel

# Save

2. Delete By Card

i

Card numbs:15977131

U

se

r

C

ar

d

* Cancel

# Save

Please Input Room Code

3. Delete By M.code

[ - - - ]

* Cancel

# Save

Please Input Room Code

3. Delete By M.code

[ 0 0 1 ]

i

* Cancel

# Save

Card Count: 320

4. Cards Information

* Cancel

# Save

[ - - - - - - - - ]

5. Format

Please Input Password

* Cancel

# Save

[ 66666666 ]

5. Format

Please Input Password

i

CONFIGURATION

Debug State

To search the Gateway and Online Monitors,

 enter

 the monitor code

 

number

(address)

 to search.

While

 working 

in

 debug 

state,

 

press "1#" to enter 

the 

tools page.

Enter

 the search 

range

 required

,

 

then 

press “#” to start 
search.

To search the online door stations(Max.4 door station

s

 can be

 

searched) and other accessories.

VOLTAGE MEASURE

MENT

To check the voltage of 

a

 monitor,

 

Note:

 

t

he monitor must be 

online.

While

 working 

in

 debug 

state,

 

press "1#" to enter 

tools page.

Press NO.“6” to enter 

Voltage Measure

 item.

Enter

 the 

monitor 

code,

 

then press “#” to search.

Press NO.“5” to enter 

'

Online Devices

'

.

Press NO.“4” to enter

  

'

Online Monitors

'

.

• 

Select 2 to 

'

Delete By Card

'

•  Select

 

3 to 

'

Delete By M.code

'

3.Card Information:

  Select

 

4 to enter

 the 

Card 

Information 

page, card count will be showed.

4.Format:

  Select  5 to enter

 the

 

Format

 page.

 Enter the

 8

 

digit

 password to start format.

-8-

DMR18S Technical Menu

Содержание DMR18S

Страница 1: ... 3 6 5 4 7 8 9 0 RF CARD CONTENTS INTRODUCTION 2 Installation Guide 2 CONFIGURATIONS 4 Debug State 4 Work Mode 8 Software Update 10 Tone Update 10 UI Update 11 Namelist Update 12 CDV DDPs TECHNICAL MANUAL by SD Card 12 by CDV Config 13 ...

Страница 2: ...s to fix the metal box Attach the unit to the rainy cover correctlly The last view for all mounting The view for rainy cover after mounted Adjust the camera angle and attach the metal to the panel and wire correctly Camera angle 3 1 2 3 4 7 5 6 Drill a hole and attach the rainy cover to it Attach screws to fix the metal box Attach the unit to the rainy cover correctlly Attach the baffle to protect...

Страница 3: ...C24V Camera Lens 1 4 ACS 4T image sensor Power consumption Standby 33mA Working status 157mA Screen 3 5 inch TFT Resolution 320 R G B X240 pixels Video signal CCIR EIA optional Wiring 2 wires non polarity Dimension 350 H 128 W 46 D mm Note The diagram take the monitor of DT47M for example DMR18S Technical Menu 3 2 The Unlock Mode Parameter must be set to 0 by default 3 Jumper set to position 1 2 f...

Страница 4: ...ug State is the starting point for using all the applications on DMR18S When door station is in standby press key Enter 9008 then enter the Admin Code 66666666 by default Debug state menu is launched 1 Go to Tools setting In Debug State calling and conversation are available you can enter 0 9 to select the volume you require see the following image While working in debug state press 1 to enter too...

Страница 5: ......

Страница 6: ...efault D e b u g S t a t e 0 Redial 1 Tools 2 Exits Cancel Save 1 Language 0 00 English Cancel Save 2 Tone Select 01 00 Mute 01 Tune 02 English Cancel Save 0 9 3 Tone Volume 3 9 Default Select 9 to enter Default setting page Input the setup code to restore factory setting 6 Waiting Time Select 6 to enter Waiting Timing setting page The setting range is from 006 600s 7 Talk Time Select 7 to enter T...

Страница 7: ...ting page 1111 is the default unlock code Input 4 digit numbers to set a new code Except for 8001 8019 and 9008 At this point a private unlock code can be set follow the steps below RF CARD Long press to enter private code setting Save Long press button 4 Unlock Code 1111 0 0 9 I n p u t r o o m n u m b e r S e t t i n g c o d e 0 0 5 8 8 8 8 I n p u t n e w p a s s w o r d S e t t i n g c o d e 0...

Страница 8: ... 0 Redial 1 Tools 2 Exits Card Memory Show the card Cancel Save Please input room code 1 Add Card Cancel Save Show the card 0 0 1 1 Add Card Cancel Save Card Numbs 05410469 0 0 1 1 Add Card Input 001 i Updated CONFIGURATION Debug State CARD MANAGEMENT While working in debug state press 1 to enter tools page Note the diagram uses 0 mode as an example Press NO 3 to enter Card Manage 8 About Select 8...

Страница 9: ...lease Input Room Code 3 Delete By M code Cancel Save Please Input Room Code 3 Delete By M code 0 0 1 i Updated Cancel Save Card Count 320 4 Cards Information Cancel Save 5 Format Please Input Password Cancel Save 66666666 5 Format Please Input Password i Updated CONFIGURATION Debug State To search the Gateway and Online Monitors enter the monitor code number address to search While working in debu...

Страница 10: ...n Code 66666666 by default Select 5 to enter Work Mode page The Standard Mode is used in a small capacity system under 32 monitors and without a BDU unit Generally dial 01 32 to call the monitor Input Mode Setting In standby mode Enter 8001 Code 66666666 by default then select 5 to set the Doorplate Mode for example enter the code 15 to call the monitor Input Mode In standby mode Enter 8001 Code 6...

Страница 11: ...3th floor and 02 corresponds to the second room number Gateway Mode is used for a community network system a common door station is connected into the system which can call all the monitors the other door stations connected at each block can only call the monitors in that block Input Mode In standby mode Enter 8001 Code 66666666 by default then select 5 to set the Doorplate Mode for example enter ...

Страница 12: ...e update software file DMR18S bin provided by our company to SD card by computer 6 When the update is finished it will return to Standby Mode interface 4 Select 1 to enter Firmware update the screen will show update ready 5 Insert the SD card into the slot shown below Download will be displayed when the updated is in progress After 3 seconds a long sound BEEP will be heard to start the update This...

Страница 13: ...D card 2 Edit UI file CONFIGURATION System Update If other languages are required please record the audio file in the language required Then send the audio file to our company a Ring bin file will be created for you to update the tone select 2 to enter 4 Select 2 Voice update to enter Tone update the screen will show Update Ready 5 Insert the SD card into the slot shown below Download will be disp...

Страница 14: ...date is finished it will return to Standby Mode display And show the new UI Create a TXT file named NameList Input Enter the number to call the monitor Name As it would be displayed on screen Gateway Set the gateway mode according to the BDU address 08 15 means BDU address 01 08 Router Set the Router mode according to BDU address 01 08 means BDU address 01 08 Address Set the monitor address requir...

Страница 15: ...y Mode CDV Config software is to enable parameter setting of the CDV DDP i e namelist setting etc The CDV Config software operation is as follows 1 Open the CDV Config software connnect the CDV DDP to a PC via USB RS 485 Click Setting on the menu bar then click Com to select the correct Com port Com port information can be found in My Computer Properties Device Manage Ports 2 Then if the CDV DDP i...

Страница 16: ...e CDV DDP After a few seconds a window will be displayed if it is updated successfully Check Name List on CDV DDP Set the CDV DDP Work Mode to 0 for more details refer to Work Mode setting section Press touch button to enter Name List page See the following picture 4 2 Router Enter 01 01 to call the monitor 01 connected to BDU 1 when the system is in Router Mode Ex enter 02 02 to call monitor conn...

Страница 17: ...itor 01 connected to BDU 1 when the system is in Gateway mode EX enter 2 02 to call the monitor 02 connected to BDU 2 see the following picture Set the CDV DDP to Work Mode 2 more details refer to Work Mode setting section Set the CDV DDP to Work Mode 3 more details refer to Work Mode setting section Press touch button to enter Name List page See the following picture Check Name List on CDV DDP 16...

Отзывы: