CDVI Digitag LR DTRR1434R Скачать руководство пользователя страница 2

LED Indicators

The DigiTagLR receiver has 2 LED indicators.  The red led is always on and 
indicates that power is applied to the device and it is ready to read and decode 
transmitter signals.  The other is a tri-colour type which displays a colour 
dependant on its circumstances.  In normal operation these colours are:

OFF = No transmitters detected in the field
RED = Transmitter detected in the field but not validated in the internal memory
GREEN = Transmitter detected in the field and stored in the internal memory.  Also 
relay changed state.  This also can mean that the exit button input (EX) has been 
closed for egress purposes.

Manufactured by CDVI Wireless Spa

Via Piave, 23 - 31020 

San Pietro di Feletto (TV) - Italy

Tel. +39-0438-450860 

Fax. +39-0438-455628

A CDVI Group product

IN-

IN+

C

NO

NC

EX

RED 

Led

GREEN

Led

JP1

Rotary 
Switch

JP1 = Closed
Max sensitivity

JP1 = Open
Min sensitivity

Terminal 

Type 

description 

IN - 

Input  

0 V 

IN + 

Input 

12 - 30 Vdc 

Output 

Relay common connection 

NO 

Output 

Relay Normally open connection 

N/C 

Input 

Relay Normally closed connection 

EX 

Input / Output 

Exit button input ( Normally open , with IN-) 

 

The  guarantee  period  of  this  product  is  24  months,  beginning  from  the 
manufacturing date. During this period, if the product does not work correctly, 
due to a defective component, it will be repaired or substituted at the discretion 
of the producer. The guarantee does not cover the plastic container integrity. 
After-sale service is supplied at the manufacturer factory.

Guarantee

IS-RR1DTUK Rev. 5 del 13.06.2017

Range Adjustment

The maximum range of the receiver is dependant on environmental conditions, transmitter orientation and transmitter battery life but should 
be approximately 15M in high gain mode and the attenuator control set to position '0' and about 7M in normal gain mode with the link 
removed (recommended).  A small 2 pin jumper is present and if disconnected selects normal gain mode. Additional the attenuator control 
can be rotated to give further range reductions. The lowest range setting would therefore be with the attenuator set to '9' and the normal 
gain mode selected on the 2 pin jumper.

Programming

The receiver can store up to 30 transmitters in its internal non-volatile memory. The following programming procedures are available from 
the two small press buttons inside the unit labelled S1 and S2.

F1. Add a new transmitter / user to the internal memory:

1. Bring one new transmitter only in to the field of detection and the red light flashes frequently indicating a correct transmitter type but not 
yet stored in the internal memory.
2. Press and hold the S1 switch until red led shows then quickly release S1.
3. After a moment the new transmitter will be automatically validated by the receiver and the green led will flash 8 times to confirm. The new 
validated transmitter will now turn the relay and the green led on.
4. Remove the transmitter from the field of detection.

F2. Change the relay switch time:

1. With no transmitters in the field of detection press and hold the S1 button until the green led shows then quickly release S1.
2. Each green LED flash represents 1 second of relay time up to a maximum of 30 seconds.  Press & hold S2 after the desired amount of 
green led pulses has been shown and 8 green led flashes will be seen. Release S2.

F3. Set or unset the valid transmitter filter: 

This function allows a tag to be read once whilst in the field, resets after 30 seconds.
1. With no transmitters in the field of detection press and hold S1 until the amber led shows then quickly release S1 and quickly press S2. 
The green led flashing indicates the valid transmitter filter is on and the red flashing led indicates off.  Repeat this procedure to toggle the 
filter on and off.

F4. Delete all valid transmitters and factory reset:

1.Press and hold S2 for 6 amber led pulses. After the 6th amber flash the green led will flash 8 times to confirm full reset with no valid 
transmitters in the internal memory.

Connection legend

S1

S2

NOTE :

 

Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must 
accept any interference, including interference that may cause undesired operation of the device. 

Отзывы: