Setting a new master code

Enter the master code twice (for the first use, the master code default is 12345).  2 beeps will sound and the orange
LED illuminates to confirm that you are in programming mode.
Enter *3 then 5-digit for the new master code. The LED goes out for 1 second and an audible beep indicates that the
new master code is accepted.
Press # to exit from the programming mode. 2 beeps confirm that the reader is in standby mode.

4 beeps indicate a data computing error.

Setting operating mode and relay outputs

Enter the master code twice (for the first use, the master code default is 12345).
2 audible beeps, and the orange LED illuminates to confirm entry into programming mode.

Operating mode

Enter 

Ý

0 then the 2-digit of the operating mode

00: PIN code 

and

 proximity badge, up to 500 users (500 PIN +

500 badges)
01: Proximity badges 

only 

up to 500 users.

02: PIN codes 

or

 proximity badges, up to 500 users.

The LED goes out for 1 second and an audible beep indicates
the time delay has been accepted.

Door relay

Enter 

Ý

1, then the time in seconds:

01 equal 1 second up to 99 for 99 seconds.
00 sets a latched output (toggle on/toggle off)
The LED goes out for 1 second and an audible beep indicates
the time delay has been accepted.

Alarm Relay

Enter 

Ý

2, then the time in seconds:

01 equal 10 seconds up to 99 for 990 seconds.
00 to turn the alarm off
The LED goes out for 1 second and an audible beep indicates
the time delay has been accepted.

Press # to exit from the programming mode. 2 beeps confirm that the reader is in standby mode.

4 beeps indicate a data computing error.

Setting new user codes and proximity badges

Enter the master code twice (for the first use, the master code default is 12345).
2 audible beeps, and the orange LED illuminates to confirm entry into programming mode.

Enter the user number (000 to 499). If the LED is green, the user number is available, therefore present a badge in
front of the main reader. Once the audible beep will sound and the green LED will change to orange then enter a 5-
digit code a long beep will sound to confirm that the badge and code has been accepted. If the LED is red the user
number is unavailable, therefore press the * key twice to cancel the old badge/code. Enter another user number or
press # to exit from the programming mode. 2 beeps confirm that you have returned to standby mode.

Содержание DGPROX

Страница 1: ...Request to exit PB1 E Alarm Input M Common PB1 E and 4 O Relay 1 contact C Common T Relay 2 N O contact I1 Anti tamper switch V1 Varistor ST1 ST2 Jumper for reset Jumper for relay 1 RL1 Door relay RL...

Страница 2: ...Alarm Off Audible signals 1 beep long Validation of data in programming mode master code proximity badge or time delay Or access code validated 2 beeps short Accessing the programming mode or exiting...

Страница 3: ...up to 99 for 99 seconds 00 sets a latched output toggle on toggle off The LED goes out for 1 second and an audible beep indicates the time delay has been accepted Alarm Relay Enter 2 then the time in...

Страница 4: ...ons Mode 00 Present the badge in front of the DGPROX one audible beep will sound to confirm that the badge is valid then enter the PIN code Mode 01 Present the badge in front of the DGPROX reader or o...

Страница 5: ...Time delays Function n Values Programmed values Keypad key in delay 0 10 10 sec 99 99 sec Door relay 1 01 1 sec 99 99 sec opened door before alarm 2 00 without alarm 01 10 sec 99 990 sec Master code 3...

Страница 6: ...2 V 1 4 5 12 Distance minimum 60cm maximum 50 m Auxiliary reader terminal connections Input voltage 12V or 230V 12 Power supply V Power supply 1 1 Data 2 2 Buzzer 3 3 Green LED M 4 Common 5 5 Red LED...

Страница 7: ...7 Template DGPROX 31 mm 26 mm 110 mm 125 mm 137 mm 29 mm 22 mm 45 mm 68 mm 86 mm Wiring Access Area 30 x 40 mm...

Страница 8: ...8...

Страница 9: ...erence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the us...

Отзывы: