![CDVI DGPROX Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/cdvi/dgprox/dgprox_manual_2577048003.webp)
3
Setting a new master code
Enter the master code twice (for the first use, the master code default is 12345). 2 beeps will sound and the orange
LED illuminates to confirm that you are in programming mode.
Enter *3 then 5-digit for the new master code. The LED goes out for 1 second and an audible beep indicates that the
new master code is accepted.
Press # to exit from the programming mode. 2 beeps confirm that the reader is in standby mode.
4 beeps indicate a data computing error.
Setting operating mode and relay outputs
Enter the master code twice (for the first use, the master code default is 12345).
2 audible beeps, and the orange LED illuminates to confirm entry into programming mode.
Operating mode
Enter
Ý
0 then the 2-digit of the operating mode
00: PIN code
and
proximity badge, up to 500 users (500 PIN +
500 badges)
01: Proximity badges
only
up to 500 users.
02: PIN codes
or
proximity badges, up to 500 users.
The LED goes out for 1 second and an audible beep indicates
the time delay has been accepted.
Door relay
Enter
Ý
1, then the time in seconds:
01 equal 1 second up to 99 for 99 seconds.
00 sets a latched output (toggle on/toggle off)
The LED goes out for 1 second and an audible beep indicates
the time delay has been accepted.
Alarm Relay
Enter
Ý
2, then the time in seconds:
01 equal 10 seconds up to 99 for 990 seconds.
00 to turn the alarm off
The LED goes out for 1 second and an audible beep indicates
the time delay has been accepted.
Press # to exit from the programming mode. 2 beeps confirm that the reader is in standby mode.
4 beeps indicate a data computing error.
Setting new user codes and proximity badges
Enter the master code twice (for the first use, the master code default is 12345).
2 audible beeps, and the orange LED illuminates to confirm entry into programming mode.
Enter the user number (000 to 499). If the LED is green, the user number is available, therefore present a badge in
front of the main reader. Once the audible beep will sound and the green LED will change to orange then enter a 5-
digit code a long beep will sound to confirm that the badge and code has been accepted. If the LED is red the user
number is unavailable, therefore press the * key twice to cancel the old badge/code. Enter another user number or
press # to exit from the programming mode. 2 beeps confirm that you have returned to standby mode.
Содержание DGPROX
Страница 8: ...8...