6] OUTPUT FORMATS 26, 30 AND 44 BITS WIEGAND
Chronograms
Open collector output with internal pulls up 1K at +5V or +12V according the ST4 position.
26-bit Wiegand Output
ST5 jumper on 1.
Format 26-bit hexadecimal. The output format is 26-bit Wiegand (Signals: DATA1, DATA0 and CLOCK)
The frame is made of 26-bit and built as follow:
1 - First parity:
1-bit – even parity for the fi rst 12-bit
Code of the badge: 6 half byte represent the last 6 digit of the code (4bit = 1 digit of a code)
Each byte is transferred from bit 7 to bit 0.
2 - Second parity:
1 bit – parité impaire des 12 derniers bits
Bit 1
Bit 2 à bit 25
Bit 26
Even Parity on bit 2 to bit 13
Data (24 bit)
Odd Parity on bit 14… bit 25
Example:
code of the badge is 0100166A37.
1
0001
0110
0110
1010
0011
0111
0
Parity 1
1
6
6
A
3
7
Parity 2
The code transmitted is in hexadecimal format 166A37
Parity 1:
0 if the number of 1 in bit 2 to bit 13 is even,
1 if the number of 1 in bit 2 to bit 13 is odd.
Parity 2:
0 if the number of 1 in bit 14 to bit 25 is odd,
1 if the number of 1 in bit 14 to bit 25 is even.
0 logic
\DATA1
\CLOCK
\DATA0
50 µs
50 µs
2ms
2ms
1 logic