background image

Edition 06/2006 

 

 

 

 
 

H.

 Programming a Sub Master Code

 

 

1.

  Enter the master code twice (12345 default value master code).The red LED’s light on to confirm 

entry in programming mode.

 

 

2.

  Press A7 to enter in sub master code menu of group 1. The green LED lights on during 1 second. 

Enter the new sub master code. The green LED lights on during 1 second to confirm 
programming of the new sub master code.

 

 

3.

  Press A8 to enter in sub master code menu of group 2. The green LED lights on during 1 second. 

Enter the new sub master code. The green LED lights on during 1 second to confirm 
programming of the new sub master code.

 

 

4.

  Press A9 to enter in sub master code menu of group 3. The green LED lights on during 1 second. 

Enter the new sub master code. The green LED lights on during 1 second to confirm 
programming of the new sub master code.

 

 
5.

  Press B to exit from programming. The red LED’s light off to confirm exit from programming

 
 

I. 

. Enable/Disable Audible Feedback 

 
The audible feedback is always enabled in programming mode or when the relay is energized. 
 
To 

ENABLE

 the audible feedback at the press of any key: 

 

1.  Enter the master code twice (12345 default value master code). 

The red LED’s light on to confirm entry in programming mode. 

  

2.  Press AA. One beep is emitted. 

Enter 1 to ENABLE

 the audible feedback at the press of any 

digit key, 1 beep is emitted to confirm the new set up.  

 

To 

DISABLE

 the audible feedback at the press of any key: 

 
3.  Press AA. One beep is emitted. 

Enter 0 to DISABLE

 the audible feedback at the press of any 

digit key, 1 beep is emitted to confirm the new set up. 

 

Press B to exit from programming. 2 beeps are emitted.

 

 

 
 

 
 
 
 
 
 
 
 
 
 

 

A7 

A8 

A9 

AA 

Содержание CAASE

Страница 1: ...m Back casing 105H x 80W x 45D mm INSTALLATION The visual feedback with the green amber and red LED s is always active It is possible to activate the audible feedback by putting ST1 jumper on see page...

Страница 2: ...er code for user code modification User Group 2 1 and 3 Sub master code for user code modification User Group 3 4 and 6 Red LEDS lights on when keypad is powered C Audible Feedback 1 short beep Keypad...

Страница 3: ...igit code press 5 for a 5 digit code or press 6 for a 6 digit code The green LED lights on for 1 second to confirm the new code length 3 Press A5 to program the master code The green LED lights on dur...

Страница 4: ...ode enter the user number the red LED s flash 4 times enter the 4 5 or 6 digit user code To DELETING a user code enter the user code location and then enter 000000 for a 6 digit code 00000 for a 5 dig...

Страница 5: ...e green LED lights on during 1 second to validate the time programmed 6 Press B to exit from programming mode The red LED lights off to confirm that the keypad is in stand by operating mode Red LED fl...

Страница 6: ...sub master code The green LED lights on during 1 second to confirm programming of the new sub master code 5 Press B to exit from programming The red LED s light off to confirm exit from programming I...

Страница 7: ...his device comes with a varistor The varistor must be connected on the strike terminal electromagnet operated by the device If this product operates more than one strike each lock should have a varist...

Страница 8: ...Edition 06 2006 8 CAA SE TEMPLATE Scale 1 1...

Отзывы: