Rectifi ed and fi ltered PSU

INSTALLATION MANUAL

TErMINAL 

BLOCK OUTPUTS 

vOLTAGE

1

12v ac

2

12v ac

7 - 8

0v dc 

9 - 10

+12v dc

N

230v ac

L

230v ac

  Designed for locking devices 

   with electromagnetic locks.

  Rectifi ed, fi ltered and not regulated PSU.

  Primary and secondary inputs 

   protected by automatic fuses.

  Additional AC output.

 

Input voltage: 230v ± 10%, 50/60 Hz.

 

Max power consumption : 0.16A.

 

2 outputs:

  - Main 12V dc rectifi ed and fi ltered 

    and non-regulated.

  - Additional 12vac.

 Maximum load current:

  - 12v dc output / 1.5A (nominal), 2A (peak),

  - 12v ac output / 0.3A.

 Wall fi xing (screw and plastic anchor included)*

N

1

7

9

L

2

8

10

Mains terminal block cover in the event of mounting 

outside a standard electrical equipment box.

*Wall fi xing 

  on each side

PRODUCT PRESENTATION

IP20

-25°C to +55°C

CE compliance

WEEE & RoHS 

COMPLIANT WITH EUROPEAN STANDARDS 

EN 55022

EN 61000-3-2

EN 61000-3-3

EN 61000-4-2

EN 61000-4-3

EN 61000-4-4 

EN 61000-4-5

EN 61000-4-6

EN 61000-4-11

This product must be installed in accordance

with the local safety standards.

Inputs and outputs protected by resettable fuses. 

(After an overload or short-circuit, disconnect

the network for 1 minute to reset the fuse.)